• 제목/요약/키워드: fire loading

검색결과 189건 처리시간 0.029초

산불에 의한 활선선로의 이도변화 거동 (Temperature and Load Change behavior of Overhead Conductor under loading current due to Forest Fire)

  • 김병걸;김상수;장용호;한세원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1295_1296
    • /
    • 2009
  • The authors have published several technical reports on the deterioration of conductor due to forest fire in series so far. This is because even we have been experiencing hundreds of forest fires every year, no systematic research on conductor which is very vulnerable to fire have been fulfilled. This paper describes the sag-tension behavior of conductor under loading current normally when only partial area of a long conductor is exposed to fire. Temperaures of Overhead Conductor were different with measurement position. When the partial area of conductor was heated up to $500^{\circ}C$, 20 % of permanent tension loss was observed. This results in the increase of sag of 1.5 m when span is 300 m. The other results will be presented in the text.

  • PDF

재하 및 비재하 내화 실험을 통한 고강도콘크리트의 내화성능에 관한 실험적 연구 (A Experimental Study on the Fire Resistant Performance of the High Strength Concrete with Loading and Unloading test)

  • 김우재;김현배;김규용;김영선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.61-64
    • /
    • 2009
  • Recently, the higher buildings are, the stronger concrete are used. Ultra high strength concrete have the possibility of spalling when a fire breaks out. so the fire-resistance performance is necessary to use the ultra high strength concrete on the high-rise building. On this study, the heating test for the concrete with loading/unloading is performed for ultra high strength concrete using nylon fiber. The heating test followed by ISO-834 heating curve on the real-size specimen and the strength of concrete are 60, 80, 100, 200 MPa.

  • PDF

CFT 기둥의 축력비 및 압축강도 변화에 따른 화재거동 영향인자에 관한 실험적 연구 (An Experimental Study on the Fire Resistance effect on load ratio and compressive strength of the CFT Column under loading in fire)

  • 조경숙;김흥열;김형준;권인규;박경훈
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.371-376
    • /
    • 2010
  • The strength of steel material in a concrete filled steel tube (CFT) is reduced in fire, but the filled interior concrete structurally ensures the fire resistance due to its high thermal capacity. More, the contractibility of CFT is excellent since it can be constructed without form work. This research analyzed the interior concrete strength and deformation characteristics, which are the influence factors of the fire resistance of CFT, in proportion to the axial load ratio. The fire resistance performance according to changes of the axial load ratio showed great fluctuation. As $280{\times}280{\times}6$ CFT columns with the concrete strengths of 24 MPa and 40 MPa and the axial load ratios of 0.9, 0.6, and 0.2 in accordance with KS F 2257-1 and 7 were heated with loading to examine the fire resistance performance, the 24 MPa concrete exhibited the fire resistance time as 27, 113, and 180 minutes for the axial load ratios, 0.9, 0.6, and 0.2 respectively. In case of 40 MPa concrete, the fire resistance time were turned out to be 19 and 28 minutes for the axial load ratios, 0.9 and 0.6 respectively. The results of 40 MPa concrete showed the much lower fire resistance performance when comparing with those of 24 MPa concrete. The fire resistance performance was not increased significantly when the axial load ratio was reduced. Therefore, the deceased fire resistance performance of high strength concrete is assumed to be caused by the internal pressure increase upon the heat application.

  • PDF

CFT기둥 재하가열 실험에서의 경계조건에 따른 내화성능 영향에 관한 실험적 연구 (An Experimental Study about Fire Resistance effect on Boundary Condition of CFT Column under Loading in Fire)

  • 김형준;김흥열;박경훈;조경숙;권인규
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.389-394
    • /
    • 2010
  • A concrete filled square steel tube (CFT) is composed of the external steel material, which its strength is reduced in fire due to sudden temperature increase, and the internal concrete with high thermal capacity that can ensure the fire resistance performance of the structure. Therefore, research about the influence factors of the structural performance of CFT column is required in order to apply CFT column to a fire resisting structure, and additional research about influence for each condition is also necessary. Among the influence factors, the boundary condition between column and beam is important structurally, and it is one of the major factors that determine overall fire resisting performance. This study performed a fire experiment under loading in order to analyse the influences of CFT column to the boundary condition. As the results of the experiment, fire resistance time of 106 minutes was ensured for the clamped-end condition but 89 minutes for the hinge-end condition in case of the 360 cross section. And, fire resistance time of 113 minutes was ensured for the clamped-end condition but 78 minutes for the hinge-end condition in case of the 280 cross section. The difference in the fire resistance performance according to changes in the boundary conditions showed a tendency that larger change effect on the fire resistance performance was derived from smaller cross section area.

  • PDF

화재확산 저감을 위한 랙크 내 수평차단막 적용에 관한 연구 (Application of Horizontal Barrier on a Rack to Reduce Fire Spread)

  • 여인환;조규환
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.71-79
    • /
    • 2017
  • 적재밀도가 높으며 수직적인 적재형태를 가지는 랙크식 창고는 화재발생 시 그 피해가 매우 심각하다. 이에 미국, 일본에서는 자국의 랙크식 창고 실정에 맞는 In-Rack 스프링클러 및 수평차단막 등을 적용하여 화재확산을 최소화하는데 노력하고 있으나 국내의 경우, 그와 관련한 연구 및 제도가 전무한 실정이다. 이에 본 연구에서는 발화위치 및 수평차단막 설치간격에 따른 화재특성 확인을 위해 국내 랙크식 창고 실정을 반영한 표준랙크를 대상으로 축소모델 화재시험을 수행하였다. 그 결과, 수평차단막의 설치간격을 밀접하게 또는 빈번하게 할수록 약 30%씩의 수직 화재확산 억제성능이 발휘되는 것을 확인하였다. 아울러 수평차단막을 경계로 상하부의 온도를 측정한 결과, 차단막이 설치된 경우가 그렇지 않은 경우에 비해 온도분포가 약 2~4배 이상 높은 것으로 나타나 수평차단막의 설치가 In-Rack 스프링클러의 조기 작동에 도움을 줄 것으로 판단된다.

일정축력을 받는 콘크리트 충전 각형기둥의 경계조건 변화에 따른 화재거동특성에 관한 실험적 연구 (An Experimental Study on the Fire Behavior of CFT Column under the Constant Axial Loading Condition in Fire)

  • 김형준;김흥열;민병렬;권인규;권기혁
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.69-75
    • /
    • 2010
  • 콘크리트가 충전된 각형강관 기둥(CFT)은 외부에 강재가 노출된 형상으로 외측의 강관은 화재시 급격한 온도상승으로 인해 강도가 저하되나, 내부의 콘크리트는 열용량이 큰 재료로써 내화성능을 확보할 수 있는 구조로 구성되어 있다. CFT 기둥을 내화구조로서 적용하기 위해서는 구조적 성능에 영향을 미치는 인자에 대한 연구가 필요하며, 이에 대한 조건별 영향성에 관한 연구가 필요하다. 내화성능에 영향을 주는 주요인자는 콘크리트 압축강도.단면크기.축력비.경계조건이며, 그 중 기둥과 보의 경계조건은 구조적 측면에서 하중지지능력에 영향을 미치므로 내화성능을 지배하는 주요 인자 중에 하나이다. 실험결과 360단면에서는 양단 고정조건에서는 106분의 내화성능이 확보되나 양단 힌지 조건에서는 89분의 내화성능을 확보하는 것으로 나타났다. 280단면에서는 양단 고정조건에서는 113분의 내화성능이 확보되나 양단힌지 조건에서는 78분의 내화성능을 확보하였다.

화재에 노출된 교량하부 강합성 구조물에 대한 열-구조 연성 병렬화재해석 (Thermal-Structure Interaction Parallel Fire Analysis for Steel-Concrete Composite Structures under Bridge Exposed to Fire Loading)

  • 윤성환;길흥배;이일근;김우석;박대효
    • 한국전산구조공학회논문집
    • /
    • 제26권4호
    • /
    • pp.283-292
    • /
    • 2013
  • 본 논문은 교량 하부에서 발생된 화재에 대한 강-콘크리트 합성구조의 전반적 국부적 손상평가를 위한 수치해석적 연구이다. 수치해석의 정확성 및 효율성을 높이기 위해 구성재료의 과도 비선형 열적 열역학적 특성이 고려된 열-구조 연성병렬 화재해석 기법이 제안되고, ANSYS solver와 연결되어 해석이 수행되며, 표준화재시험과 비교 검증된다. 검증된 해석기법을 통해 국내에서 발생된 부천고가교 합성구조에 대한 화재손상해석이 수행된다. 해석결과 강박스 거더의 하부 플랜지 및 복부의 경우 임계온도를 초과하였고 구조적 처짐과 변형 형상이 화재사고 결과와 비교적 잘 일치하였다.

화재시 온도증가로 인한 RC 슬래브의 강도 특성 (Strength Properties of RC Slabs under Elevated Temperatures from Fire)

  • 임초롱;정철헌;김유석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.48-60
    • /
    • 2010
  • The fire resistance performance of 2 RC slabs after exposure to the ISO-834 fire standard without loading has been experimentally investigated. A Comparison is made of the fire resistance performance between RC slabs without PP(polypropylene) fibers and RC slabs with PP fibers. From the fire test results, the presence of PP fibers in RC slabs can reduce spalling and enhance their fire resistance. Until now, the determination of fire resistance of reinforced concrete(RC) slabs has essentially been based on tabulated data. According to ACI 216 code and EUROCODE 2, the design of concrete structures is essentially based on tabulated data for appropriate concrete cover and various fire durations. From the comparison between fire test results and codes, current fire design provisions of codes such as the ACI 216 and the EUROCODE 2 are unconservative for estimating mechanical properties of RC slabs at elevated temperatures.

변전소 철골 내화뿜칠 부착강도 기준설정에 관한 실험적 연구 (The Experimental Study on the Suggestion for Bond Strength Standard of Sprayed Fire Resistive Materials Used at the Substation Steel Structures)

  • 박동수;정원섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.128-137
    • /
    • 2014
  • 내화뿜칠재는 주로 철골구조물 위에 시공하여 내화구조기준을 만족하기 위한 것이다. 국내에서는 원자력발전소를 비롯하여 철골구조물에 내화뿜칠재를 시공하여 왔지만, 재료특성 중 중요한 요건인 부착강도기준이 제정되어있지 않았다. 다만, 원자력발전소는 원전의 기준에 따라 부착강도 기준이 있었다. 본 논문에서는 변전소에 시공되는 내화뿜칠재의 부착강도 기준을 정하고자 하였다. 기준설정 방법은 현재 사용되는 제품으로 실험체를 제작하고, 변전소 환경에 따라 열화시키며 부착강도를 측정하고 구조물 내구연한 기간 동안 열화시킨 후 변전소에서 발생하는 충격하중 실험을 통하여 탈락여부를 평가하여 부착강도기준을 설정하였다. 본 논문에서의 부착강도는 시중에서 사용되는 제품을 기준으로 실험한 것으로 최소한의 값이라고 판단된다.