• Title/Summary/Keyword: fire investigations

Search Result 79, Processing Time 0.032 seconds

A Study on the Risks Factors of Fire Occurrence and Expansion for Traditional Markets (전통시장 화재 발생 및 확대 위험요인에 관한 연구)

  • Kim, Jung-Gon;Park, Chang-Il;Jung, Jae-Wook;Kim, Seong-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • Purpose: Traditional markets often have irregular space utilization patterns because the spaces are created and divided as time passed. Internally, there is high risk of fire due to problems such as aging facilities and high-density of stores and externally, there is high risk of fire spread since it is often adjacent to deteriorated residential and commercial facilities. Method: In this paper, on-site investigations were carried out to check fire risk factors and fire spread risk, and fire occurrence and expansion risk factors were investigated for traditional markets in Hwanghak-dong and Dong-daemun by using large-scale fire data from existing traditional markets. Result: As a result of the analysis, there are likely to be various problems such as high fire load and lack of safety awareness due to aging facilities and high-density of stores. In particular, it is necessary to prepare countermeasures because deteriorated residential facilities with narrow alleys around traditional markets have high fire spread. It is situation that while traditional markets mainly are managing for fire and disaster centering on the merchant association, the surrounding residential areas are not properly managed. Conclusion: It is necessary to manage deteriorated residential facilities with traditional markets, also to be linked early warning system and information to evacuate rapidly in case of fire there.

A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System (법과 제도적 관점에서 본 소방특별조사의 개선방안)

  • Lee, Jae Wook;Jeong, Gi Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.545-552
    • /
    • 2021
  • Under the Act amended on August 4, 2011, a special fire-fighting investigation was conducted by the relevant person (owner, manager, oil refineries), and the responsibility was also given to the relevant person. Instead of directly entering all existing fire-fighting targets and investigating the maintenance and management status of fire-fighting facilities, the fire-fighting agency selects and visits some targets every year, checks the maintenance and management status of fire-fighting facilities, corrects them, and imposes fines, etc. Reasons for the introduction of the system were the establishment of a private autonomous correction system by strengthening the responsibility of officials, lack of firefighting professionals, possible corruption due to frequent public contact, and responsibility of fire agencies. However, many problems arose even after the introduction of a special fire investigation system. A special fire investigation, one of the fire safety systems, checks whether related public officials and especially fire officials are properly installed, maintained and managed in accordance with relevant laws. Special firefighting investigations were introduced as firefighting inspections at the time the firefighting law was enacted in 1958, and have undergone a revised process more than 30 times until recently. Firefighting Facility Installation, Maintenance and Safety Management Act", the existing firefighting inspection was changed to a special firefighting investigation and accepted. At the time of enactment of the Fire Service Act in 1958, a special firefighting investigation was introduced as a firefighting inspection, and until recently, more than 30 revisions have been made. In 2003, as the existing fire fighting system was divided into four laws, it was approved by changing the existing fire fighting inspection to a special fire fighting investigation in the "Fire Fighting Facility Installation, Maintenance and Safety Management Act".

A Study on the Combined Heat Transfer and Analysis Fire Induced Combustion Gas in a partially Open Enclosure (개구부가 있는 밀폐공간내 화재의 복합열전달 및 연소가스 분석에 관한 연구)

  • Park, Chan-Kuk;Chu, Byeong-Gil;Kim, Cheol
    • Fire Science and Engineering
    • /
    • v.11 no.1
    • /
    • pp.21-35
    • /
    • 1997
  • The natural convection and combined heat transfer induced by fire in a rectangular enclosure is numerically studied. The model for this numerical analysis is partially opened right wall. The solution procedure includes the standard k-$\varepsilon$ model for turbulent flow and the discrete ordinates method (DOM) is used for the calculation of radiative heat transfer equation. In numerical study, SIMPLE algorithm is applied for fluid flow analysis, and the investigations of combustion gas induced by fire is performed by FAST model of HAZARD I program. In this study, numerical simulation on the combined naturnal convection and radiation is carried out in a partial enclosure filled with absorbed-emitted gray media, but is not considered scattering problem. The streamlines, isothermal lines, average radiation intensity and kinetic energy are compared the results of pure convection with those of the combined convection-radiation, the combined heat transfer. Comparing the results of pure convection with those of the combined convection-radiation, the combined heat transfer analysis shows the stronger circulation than those of the pure convection. Three different locations of heat source are considered to observe the effect of heat source location on the heat transfer phenomena. As the results, the circulation and the heat transfer in the left region from heating block are much more influenced than those in the right region. It is also founded that the radiation effect cannot be neglected in analyzing the building in fire. And as the results of combustion gas analysis from FAST model, it is found that O2 concentration is decreased according to time. While CO and CO2 concentration are rapidly increased in the beginning(about 100sec), but slowly decreased from that time on.

  • PDF

A Study on Application of Combustion Products for Forest Fire Investigation (산불화재 감식을 위한 연소생성물의 응용에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.111-119
    • /
    • 2011
  • This study was designed to provide basic data applicable to fire investigation through consideration of combustion products and propose vulnerability of combustibles through analysis of $CO_2$ emission. In order to achieve these research objectives, characteristics of combustion products such as smoke release rate of each part(raw leaves, branches and barks), $CO_2$ emission and ash production were considered targeting on 6 oak species(Quercus variabilis Blume, Quercus aliena Blume, Quercus serrata, Quercus mongolica Fisch, Quercus dentata Sapling and Quercus acutissima) using cone calorimeter and smoke density tester. As a result, it was found that raw leaves release smoke more relatively than branches and barks, when they burn, and that Quercus variabilis Blume has the highest smoke density. Also, Quercus acutissima released CO and $CO_2$ which are respectively, 6.67 times and 1.43 times more than Quercus variabilis Blume with low $CO_2$ emission. In addition, branches released CO and $CO_2$ more relatively. There was a big difference in ash production among raw leaves(3.1 g), branches(10.5 g) and barks(16.43 g). It was identified that Quercus serrata produces ashes which are nearly 9.95 times more than Quercus variabilis Blume. It demonstrates that Quercus serrata contains relatively higher minerals and that Quercus variabilis Blume can leave lots of traces like stain and carbonization, as it releases smoke a lot and it's difficult to predict visibility, when a forest fire breaks out in its community area. It is also considered that smoke particles containing oil in the air leave strain on the surface of a tree, and that CO and $CO_2$ emission increases, when crown fire to burn branches breaks out.

Experimental Studies on the Risk Assessment of Electrical Fire and Shock of LED Lighting for Outdoor (옥외용 LED 조명의 전기화재 및 감전 위험성 평가에 대한 실험적 고찰)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yoen;Moon, Hyun-Wook;Kim, Hyeog-Soo;Kim, Myung-Soo;Kim, Man-Geon
    • Congress of the korean instutite of fire investigation
    • /
    • 2011.04a
    • /
    • pp.77-97
    • /
    • 2011
  • In this paper, we studied risk assessments of electrical fire and shock of LED lightings for outdoor. We examined national regulations about the LED lighting for outdoor and analyzed the appearances and compositions of LED lightings. And, We experimented about water proof, line to line fault, line to line breakdowm, overvoltage, line to line leakage in overhead line or water of LED lighting. From experimental results, we know that there are risks of electrical fire and shock by abnormal conditions at the LED lighting. Therefore, the uses of protective devices and insulated type of converter are required for the electrical safety. We expect that the results of this study would be helpful for the improvement of regulations and standards for electrical safety and for the investigations of electrical accidents of LED lightings.

  • PDF

A Study on the Improvement Plans of Police Fire Investigation (경찰화재조사의 개선방안에 관한 연구)

  • SeoMoon, Su-Cheol
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.9 no.1
    • /
    • pp.103-121
    • /
    • 2006
  • We are living in more comfortable circumstances with the social developments and the improvement of the standard of living, but, on the other hand, we are exposed to an increase of the occurrences of tires on account of large-sized, higher stories, deeper underground building and the use of various energy resources. The materials of the floor in a residence modern society have been going through various alterations in accordance with the uses of a residence and are now used as final goods in interioring the bottom of apartments, houses and shops. There are so many kinds of materials you usually come in contact with, but in the first place, we need to make an experiment on the spread of the fire with the hypocaust used as the floors of apartments, etc. and the floor covers you usually can get easily. We, scientific investigators, can get in contact with the accidents caused by incendiarism or an accidental fire closely connected with petroleum stuffs on the floor materials that give rise to lots of problems. on this account, I'd like to propose that we conduct an experiment on fire shapes by each petroleum stuff and that discriminate an accidental tire from incendiarism. In an investigation, it seems that finding a live coal could be an essential part of clearing up the cause of a tire but it could not be the cause of a fire itself. And besides, all sorts of tire cases or fire accidents have some kind of legislation and standard to minimize and at an early stage cope with the damage by tires. That is to say, we are supposed to install each kind of electric apparatus, automatic alarm equipment, automatic fire extinguisher in order to protect ourselves from the danger of fires and check them at any time and also escape urgently in case of fire-outbreaking or build a tire-proof construction to prevent flames from proliferating to the neighboring areas. Namely, you should take several factors into consideration to investigate a cause of a case or an accident related to fire. That means it's not in reason for one investigator or one investigative team to make clear of the starting part and the cause of a tire. accordingly, in this thesis, explanations would be given set limits to the judgement and verification on the cause of a fire and the concrete tire-spreading part through investigation on the very spot that a fire broke out. The fire-discernment would also be focused on the early stage fire-spreading part fire-outbreaking resources, and I think the realities of police tire investigations and the problems are still a matter of debate. The cause of a fire must be examined into by logical judgement on the basis of abundant scientific knowledge and experience covering the whole of fire phenomena. The judgement of the cause should be made with fire-spreading situation at the spot as the central figure and in case of verifying, you are supposed to prove by the situational proof from the traces of the tire-spreading to the fire-outbreaking sources. The causal relation on a fire-outbreak should not be proved by arbitrary opinion far from concrete facts, and also there is much chance of making mistakes if you draw deduction from a coincidence. It is absolutely necessary you observe in an objective attitude and grasp the situation of a tire in the investigation of the cause. Having a look at the spot with a prejudice is not allowed. The source of tire-outbreak itself is likely to be considered as the cause of a tire and that makes us doubt about the results according to interests of the independent investigators. So to speak, they set about investigations, the police investigation in the hope of it not being incendiarism, the fire department in the hope of it not being problems in installments or equipments, insurance companies in the hope of it being any incendiarism, electric fields in the hope of it not being electric defects, the gas-related in the hope of it not being gas problems. You could not look forward to more fair investigation and break off their misgivings. It is because the firing source itself is known as the cause of a fire and civil or criminal responsibilities are respected to the firing source itself. On this occasion, investigating the cause of a fire should be conducted with research, investigation, emotion independent, and finally you should clear up the cause with the results put together.

  • PDF

A Study on the Improvement of Dangerous Goods Safety Management in Maritime Terminal (항만 옥외저장소 위험물의 안전관리 개선 방안)

  • Lee, Bong-Woo;Shin, Se-Cheol;Park, Kyung-Jin;Choina, Yeong-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.393-401
    • /
    • 2020
  • According to the research and investigations performed on Port Facilities for cargo-works of hazardous materials around the Port of Busan, a conclusion was drawn that the manually operating foam tower monitors are ineffective as they are hard to access due to the radiant heat under contingency circumstances such as a fire. Moreover, in some cases, the effective range of Foam Tower Monitors are insufficient to reach docked ships and manifolds where hazardous materials are being unloaded. In addition, Dangerous Goods freights are inadequately and inefficiently stored regardless properties of hazardous substances due to complicated local regulations, and some are equipped with inapplicable facilities for docked ships. Therefore, in order to effectively counteract the contingencies and obtain safety, it would be recommended to install adequate facilities.

Study on Applications of Bulbus Fritillariae Main Blended Prescription from Donguibogam (동의보감(東醫寶鑑) 중(中) 패모(貝母)가 주약(主藥)으로 배오(配伍)된 방제(方劑)의 활용(活用)에 대한 고찰(考察))

  • Lim, Dae-Hwan;Yun, Young-Gab
    • Herbal Formula Science
    • /
    • v.13 no.2
    • /
    • pp.125-140
    • /
    • 2005
  • This report describes 48 studies related to the use of Bulbus Fritillariae main blended prescriptions from Donguibogam. The following conclusions were reached through investigations on the prescriptions that use Bulbus Fritillariae as a key ingredient. All kinds of infection in a cough and the malignant tumor recorded the largest number of clinical frequency of the prescriptions in therapeutic use when Bulbus Fritillariae was taken as a principle medicine. The Prescriptions are compounded with Bulbus Fritillariae as a principle medicine can aplly to respiratory disease, eye disease, nose and ear disease, throat disease, a boil. Various pathogenic factors such as consumptive disease, phlegm, phlegm-fire, invasion by wind, affective by cold, fire, dyspepsia-fire are put to practical use. The dosage of Bulbus Fritillariae is 5 bun (about 1.88g) to 1 lyang(about 37.5g), however 1 jeon(about 3.75g) has been taken the most for clinical application. With examination the formulae of presciptions containing Bulbus Fritillariae, I found the basic prescriptions as well as the medicines are in conjunction with Bulbus Fritillariae and the theoretic grounds of formula in combining Bulbus Fritillariae as a group of medicine for presciption through this reseach.

  • PDF

Early Vegetational Succession of Burned Area in Mt. Ssalibagu (싸리바구山 山火跡地의 初期植生 邊移)

  • Kim, Jong Hong;Han Sung Jang
    • The Korean Journal of Ecology
    • /
    • v.8 no.2
    • /
    • pp.109-117
    • /
    • 1985
  • This report is a part of the investigations of the secondary vegetation successions carried out and the analysis of soil properties in the burned areas of forest. The fires-crown fire and surface fire-were occurred at April, 1978 and February, 1984. The investigations were carrited out from August 10. 1983 to September 25, 1984. The burned areas studied are located in southern slope of Mt. Ssalibagu (above sea-level, 590m), So-myon, Sungju-gun, Chollanam-do, Korea. The results are as follows: The floristic compositions of the burned area at the 5th year after the fires were 85 families, 250 genera, 321 species and 53 varieties. Among them, 85 families, 127 genera, 129 species and 30 varieties were found in the currently burned area. In all the sampling sites (10*10cm), 31 and 57 species were found in the currently burned and in the 5th years after the fires, respectively. Miscanthus sinensis var. purpurascens, Quercus serrata and Festuca ovina were dominant species in the both areas. Biological spectra in both the burned areas showed $H-D_1-R_5-e$ type. Degree of the succession(DS) was 412-884 in the 5th years passed burned area and it was high level. Species diversity index(H) was 0.59~1.13 and evennes index(e) was 0.43~0.79, these indexes between both areas were different considerably. Indexes of similarity between both areas were different, too, but that between $B_1$ and $B_6$ was the highest (CCj=0.5). Probably this phenomenon is due to the great numbers of the pine trees appeared simulataneously. Content of the organic matter, N, P, K and Ca of soil in the burned area at the 5th years after the fires was lower than that of soil in the currently burned area.

  • PDF

Analysis on Emergency Power Supplies in Buildings and a Model for Safe Operation of the Emergency Power System (건축물의 비상전원 적용실태 및 자가발전설비의 안전 운전 모델에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.49-56
    • /
    • 2012
  • The purpose of this paper is to present a model for operating an emergency power system(EPS) that can secure a sufficient power supply used in case of a fire by analyzing the status of power supplies for emergency and firefighting operations. Investigations on the one of the causes of the operational failure of firefighting systems show evidence of EPS. Generally, when power to a building is interrupted, EPS supplies the emergency load(excepted firefighting load) first. When a power outage and a fire occur simultaneously, the EPS must be able to supply both the emergency load and the firefighting load, especially the firefighting load to the end. However, in order to save construction costs, emergency power generators in apartment, commercial, and business buildings can satisfy only one of the required loads. In cases like this, when a power outage and a fire occur simultaneously, there is a danger of firefighting equipment not operating due to insufficient power supply from the emergency generator. Therefore, an EPS must have a reserved firefighting power that can supply both the firefighting and the emergency load. Such EPS, when faced with a danger of an overload, will shut down the supply to all or part of the emergency load, thus securing a continuous power supply to the firefighting equipment. The generator power system with reserved firefighting power (RFP) will also have an indicator to show that the selective control is being used. General power generation systems for emergency load and firefighting load were found to have a demand factor of 50-60% with a lump. However, when installing an EPS, the builders must choose the higher demand factor suggested according to the official approval demand factor of the building.