• 제목/요약/키워드: fire hazards

검색결과 211건 처리시간 0.026초

Managing the Vulnerability of Megacities in North America and Europe to Seismic Hazards

  • Waugh, William L.
    • 한국화재소방학회논문지
    • /
    • 제15권2호
    • /
    • pp.20-30
    • /
    • 2001
  • The science and technology of seismic hazard mitigation are increasingly being shared among scientists and policy makers around the world. Administrative expertise is also being shared. While there is still tremendous unevenness in technical and administrative capacities and resources, a global community of emergency managers is developing and there is a globalization of expertise. Hazards are better understood, tools for risk assessment are improving, techniques for hazard mitigation are being perfected, and communities and states are implementing more comprehensive disaster preparedness, response, and recovery programs. Priorities are also emerging and hazard mitigation has emerged as the priority of choice in North America and Europe. An increasingly important component of hazard mitigation is resilience, in terms of increased capacities for disaster mitigation and recovery at the community and even individual levels. Each year, more is known about the locations and natures of seismic hazards, although there are still unknown and poorly understood fault lines and limited understanding of related disasters such as tsunamis and landslides. More is known about the impact of earthquakes on the built environment, although nature still provides surprises to confound man's best extorts to reduce risk. More is known about human nature and how people respond to uncertain risk and when confronted by certain catastrophe. However, despite the increased understanding of seismic phenomena and how to protect people and property, there is much that needs to be done to reduce the risk, particularly in major metropolitan areas.

  • PDF

통계적 고찰과 수목분포에 따른 열량분석을 통한 산림화재 위험성 평가에 관한 연구 (A study on the assessment of wildland fire hazard through statistic examination and calorie analysis according to the geographical distribution of vegetation)

  • 김광일;김동현
    • 한국화재소방학회논문지
    • /
    • 제14권3호
    • /
    • pp.27-32
    • /
    • 2000
  • 산림에 대한 화재 위험성 평가는 산불의 예방, 진화 및 관리에 있어서 우선적으로 고려되어야 할 부분이다. 단일 화재로서는 축내 최대 규모인 1997년 4월에 발생한 강원도 고성산불과 2000년 4월에 발생한 강원도 영동지방 산불은 이러한 화재위험성 평가의 필요성을 절실히 요구하고 있다. 현재 국내에서의 사용하고 있는 위험도의 표현은 기상인자에 의해 연료가 화재에 노출될 수 있는 위험을 나타낸 것으로 습도측정봉 무게 환산식을 통해 산불 발생 위험지수 산정하여 산불경보시스템을 사용하며 나타내고 있다. 앞으로, 지역별 종합적인 산림화재 위험성 평가를 위해서는 주요 인자들의 위험성을 측정하고 통계적 고찰을 통한 위험성 평가를 표현할 필요성이 있다. 이에 본 연구에서는 먼저 통계적 고찰을 통해 발생 빈도와 피해의 심각성을 분석하여 위험성을 평가하였고 수목의 열량적 가치를 시차주사열량계 실험을 통해 분석하여 수목분포도에 따를 열적 상대 위험성을 평가하였다

  • PDF

소방공무원들의 현장 활동 시 석면노출의 위험성과 대응방안 (The Risk and Countermeasures of Asbestos Exposure at the Scene Activities of Fire Officials)

  • 이정일
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.68-78
    • /
    • 2010
  • 본 연구의 목적은 소방공무원들이 현장 활동 중에 석면함유 비산먼지로 위협되고 있는 현상에 대한 심각성을 사례 및 설문을 통해 발생 원인을 찾아 현장 활동 중에 석면노출을 효과적으로 예방하는데 있다. 소방관들의 현장 활동과 석면분진의 위험성에 대한 상관관계를 설문조사를 하여 분석하고 석면으로 인해 발생하는 석면폐암, 악성중피종과 같은 질병으로부터 소방공무원을 보호하고, 불합리한 여건들을 변화시킴으로써 조직운영의 최적화와 안전하고 쾌적한 근무여건을 통하여 소방공무원들이 현장 활동에서 치명적인 위해요소를 사전에 제거 하거하고자 한다. 또한 석면노출 기준에 따른 보호 장비 착용으로 철저한 소방 활동을 강화함은 물론, 소방 활동상 유해성인자의 심각성을 인식하고, 질환 피해보상에 대한 법적 제도를 마련하여, 아직까지 인정되고 있지 않은 질병에 대한 공무상 재해인정을 통한 제도적 미비점을 보완하여, 소방공무원의 사기진작 및 근무여건개선으로 대 국민 서비스 향상 등을 기대하고자 한다.

원자기여법에 근거한 유기 할로겐 화합물의 순연소열 예측 (Prediction of the Net Heats of Combustion of Organic Halogenated Compounds based on the Atomic Contribution Method)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.7-12
    • /
    • 2003
  • 연소열은 인화성 물질의 화재$.$폭발 위험성을 결정하는 주요한 물성치이다. 할로겐화 유기화합물의 순연소열을 예측하기 위해서, 원자기여법에 기반을 둔 경험식들이 개발되어 왔다. 본 연구에 개발된 경험식을 Cardozo와 Hanley의 경험식들과 비교해 보았다. A.A.D.를 보면 알 수 있듯이 본 연구에서 제안된 경험식으로 계산된 값이 실험값에 가장 근접해 있음을 확인하였다. 따라서, 본 연구에서 제안된 경험식은 여타 할로겐화 유기화합물의 연소열을 예측하는데 도움을 줄 것으로 사료된다.

The Effects of Activities and Working Conditions on Fire Accidents on Construction Sites

  • Yi, Kyoo-Jin
    • 한국건축시공학회지
    • /
    • 제20권4호
    • /
    • pp.383-389
    • /
    • 2020
  • Accidents on construction sites involving fires do not occur as often as accidents involving falls from height or collapses. However, once a fire accident occurs, there is a high risk of a large number of casualties. Fire on construction sites is affected by working conditions and the types of activities the construction workers are engaged in at the sites. This study aims to identify activities and working conditions at construction sites that are vulnerable to fire, and analyse how they correlate with each other and how they affect the causes and consequences of fire accidents at construction sties. I analysed 40 fire accident reports and listed the situations vulnerable to fire at construction sites considering direct causes, activities, and working conditions. The most dangerous combination of fire hazards can be the heating devices used during rest/sleep in the office/cabin/storage during cold weather. The next most hazardous combination can be sparks arising from painting, waterproofing, insulation, plumbing, or welding/melting work in an underground or confined space.

건축물내 통신용 케이블의 화재위험성 분석에 관한 실험연구 (A Experimental Study on the Fire Hazard Analysis For Communication Cable in Buildings)

  • 홍성호;최문수
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.20-25
    • /
    • 2011
  • This study presents on the fire hazard analysis of communication cable in buildings. In order to analyze fire hazards for communication cable IEC 60332-1, UL 94 and cone calorimeter test are conducted. The number of cable used to experiment is 10 communication cable which are generally applied to data communication in buildings. The results show that 9 cables do meet the performance requirement of IEC 60332-1 and 8 cables are V-0 classification. IEC 60332-1 and UL 94 test are inadequate for fire hazard classification. The various parameters obtained by cone calorimeter test such as HRR, peak HRR, smoke production rate and so on. Also it is able to evaluate multiply fire hazard for communication cable with cone calorimeter test results.

고층에서의 콘크리트와 철근의 팽창 및 수축 (Thermal expansion and Shrinkage of concrete and Steel bar)

  • 오창희;김화중
    • 한국화재소방학회논문지
    • /
    • 제2권1호
    • /
    • pp.11-20
    • /
    • 1988
  • The success of analyzing the behavior of reinforced concrete structures at elevated temperature greatly depends on how accurately certain thermal properties, especially thermal expansion, specific heat and density thermal conductivity can be determined in a wide temperature range. In this Paper, in order to Predict the behavior of reinforced concrete structure in fire hazards thermal expansion characteristics of normal concrete are formulated through experimental investigation.

  • PDF

HTTP를 이용한 원거리 가스누출 감시 시스템에 관한 연구 (A Study of Gas Leakage Monitoring System on a Long Distance Using the Hypertext Transfer Protocol)

  • 이광희;안형일;김응식
    • 한국화재소방학회논문지
    • /
    • 제11권2호
    • /
    • pp.35-44
    • /
    • 1997
  • 본 논문은 RFC1945의 바탕을 둔 HTTP와 PLC전용프로토콜을 사용하여 시간과 장소에 구애받지 않고 위험상황을 감시할 수 있는 원거리 가스누출 감시 시스댐에 관해 연구하였다. 이를 위하여 인터네 트상에 컴퓨터와 PLC의 접속을 위해 상위네트워크와 하위네트워크를 구성하여 인터네트상의 Web을 통해 위험요소를 감시할 수 있는 원거리 가스누출 감시 시스댐을 구축하였다.

  • PDF

A Ring-Oriented Multicast Architecture over Mobile Ad Hoc Sensor networks

  • Yang, Yubai;Hong, Choong Seon
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2004년도 춘계학술발표대회
    • /
    • pp.1259-1262
    • /
    • 2004
  • Detecting environmental hazards and monitoring remote terrain are among many sensor network applications. In case of fire detection, it is significantly valuable to monitor fire-spot's shape and trend in time. Mobile ad hoc sensor nodes right round are responsible for sensoring, processing and networking packets, or even launching extinguisher. In this paper, we proposed a ring-oriented Multicast architecture based on "Fisheye State Routing" (MFSR) to organize a group of mobile ad hoc sensor nodes in a multicast way. It is familiar with traditional mesh-based multicast protocol [1] in mobile ad hoc network, trying to concentrates on efficiency and robustness simultaneously. Certain applications-based solution for hazards is proposed, quantitative results including architecture and recovery algorithms of MFSR are also investigated in this paper.

  • PDF

A Study on the Safe Position from the Local Fire in the Ship's Engine Rooms

  • Kim, Mann-Eun;Lee, Kyoung-Woo;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.446-454
    • /
    • 2008
  • Control devices for fire safety systems located in a engine room are to be arranged at a safe position which is easily accessible during a fire. To develop an interpretation for the safe position in engine rooms, calculation and experiments are carried out to determine a correlation between radiant heat and distance from fire in this paper. On the basis of results of this research, the control devices for a main engine are to be installed in the behind side of an obstruction to reduce radiant heat from the fire of the main engine. In case of other control devices, they are also to be provided in the same manner of control devices for the main engine or are to be placed with 5 meters far from fire hazards.