Design of performance testing device for heat exhaust ventilation fan (제연용 송풍기의 방염성능 시험장치 설계)

  • Lee, Young-Mo;Kim, Kwang-Yong;Lee, Jae-Yup;Jung, Hyun-Jong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.367-372
    • /
    • 2005
  • This study primarily is concerned with a new device which has been developed following the international standards to measure the ventilation performance at elevated temperature. This device can measure duration of ventilation, performance of electricity, static pressure at elevated temperature and also it is having provision to measure reversible performances during fire hazards. Invented device is closed circuit type system which is best suited for korean industrial environment with low cost and high efficiency. International standards has been compared and performance testing has been major using BS 7346 which is tested by Warrington Fire Research Centre.

  • PDF

Flash Points of Water+n-Propanol System Using Closed-Cup Measurement Apparatus (밀폐계 측정장치를 이용한 물-노말프로판올 계의 인화점)

  • Ha, Dong-Myeong;Choi, Yong-Chan;Lee, Sung-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.140-145
    • /
    • 2002
  • The Flash Point is one of the most important combustible properties used to determine the potential for fire and explosion hazards of chemical materials. An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The lower flash points for the Water + n-Propanol systems were measured by using Pensky-Martens closed cup tester. The experimental data were compared with the values calculated by the laws of Raoult and van laar equation. The calculated values based on the van Laar equation were found to be better than those based on the Raoult's law.

The Effect of the Change of Wind Velocity on the Classification of Explosion Hazardous Area (폭발위험장소 선정 시 풍속 변화에 관한 연구)

  • Kwon, Yong-Joong;Kim, Dong-Joon
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.62-67
    • /
    • 2018
  • It is very important to classify explosion hazardous area in order to prevent an accident explosion. In order to prevent such a explosion, the Industrial Safety and Health Standards Rules stipulates the establishment and management of explosion hazards in accordance with the criteria set by the Korean Industrial Standards. This study has investigated the range of the explosion hazardous area according to various hole sizes, pressures, vapor densities, and wind velocities in the outdoor flammable liquid tank using KS C IEC-60079-10-1 $2^{nd}$ Ed.(=IEC CODE) and PHAST. The results show that the explosion hazardous areas by IEC CODE have circle shapes. However, the areas by PHAST show ellipse shapes. The different of the explosion hazardous areas increases with the increase of wind velocity.

Analysis of Secondary Battery Trends Using Topic Modeling: Focusing on Solid-State Batteries

  • Chunghyun Do;Yong Jin Kim
    • Asian Journal of Innovation and Policy
    • /
    • v.12 no.3
    • /
    • pp.345-362
    • /
    • 2023
  • As the widespread adoption and proliferation of electric vehicles continue, the secondary battery market is experiencing rapid growth. However, lithium-ion batteries, which constitute a majority of secondary batteries, present high risks of fire and explosion. Solid-state batteries are thus garnering attention as the next-generation batteries since they eliminate fire hazards and significantly reduce the risk of explosions. Against this background, the study aimed to analyze research trends and provide insights by examining 2,927 domestic papers related to solid-state batteries over the past decade (2013-2022). Specifically, we used topic modeling to extract major keywords associated with solid-state batteries research and to explore the network characteristics across major topics. The changes in research on solid-state batteries were analyzed in-depth by calculating topic dominance by year. The findings provide an overview of the emerging trends in domestic solid-state battery research, and might serve as a valuable reference in shaping long-term research directions.

A Study on the Heat Release Characteristics of Fire Load for Performance Based Design of Multiplexes: A Focus on the Heat Release Rate and Fire Spread Rate of Cinema Seats (복합영상관의 성능위주설계를 위한 가연물의 연소발열특성 연구: 객석의자의 열발생률 및 연소확산속도를 중심으로)

  • Nam, Dong-Gun;Jang, Hyo-Yeon;Hwang, Cheol-Hong;Lim, Ohk-Kun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.11-17
    • /
    • 2020
  • As performance-based design (PBD) has a direct impact on evacuation safety assessments, designing fire scenarios based on real fire tests is essential. To improve the reliability of the PBD for fire safety in multiplexes, information on fire behavior, such as heat release rate (HRR) and fire spread rate, are provided in this study by conducting a standard fabric flammability test. To this end, several chairs were arranged in a pattern that resembled a theater-style seating. The peak HRR and heating value per unit mass for each chair ranged from 415 kW to 988 kW and 15.2 MJ/kg to 23.8 MJ/kg, respectively. The heating values per unit mass of the new and old chairs were 23.6 MJ/kg and 16.7 MJ/kg, respectively. As the quantity of plastic and cushioning materials in the new chairs was more than that of the old ones, the new chairs were more vulnerable to fire hazards. Furthermore, when the chairs were arranged in a line, the fire spread rate was observed to be 0.39-0.42 m/min, regardless of the ignition location. Finally, a fire growth curve showing the peak HRR and fire spread rate was also demonstrated.

A Study on the Safety of Small LPG Storage Tanks at External Fires (외부화재시 LPG 소형저장탱크의 안전성에 관한 연구)

  • Yim, Ji-Pyo;Ma, Byung-Chol;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.64-72
    • /
    • 2015
  • The purpose of this study is to study the safety of a small LPG storage tank with a capacity less than 3 ton when it is exposed to an external fire. First, simulation studies were carried out using ASPEN Plus and PHAST to demonstrate that overpressurization in the tank can be relieved by discharging the LPG through an adequately sized safety valve, but the release may lead to the secondary risk of fire and explosion around the tank. Next, the temporal variations of the temperatures of the lading and tank wall were obtained using AFFTAC, which showed that the tank wall adjacent to the vapor space could be overheated in about 11 min to such a point that the weakened strength might cause a rupture of the tank and subsequent BLEVE. The consequences of the BLEVE were estimated using PHAST. Finally, several practical measures for preventing the hazards of overheating were suggested, including an anti-explosion device, sprinkling system, insulation, heat-proof coating, and enhanced safety factor for tank fabrication. The effectiveness of these measures were examined by simulations using AFFTAC and ASPEN Plus.

Prediction of Explosion Limits of Organic Acids Using Combustion Chemical Stoichiometric Coefficients and Heats of Combustion (연소열 및 화학양론계수를 이용한 유기산류의 폭발한계의 예측)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.47-51
    • /
    • 2013
  • The explosion limit is one of the major combustion properties used to determine the fire and explosion hazards of the flammable substances. The explosion limit of organic acids have been shown to be correlated the heat of combustion and the chemical stoichiometric coefficients. In this study, the lower explosion and upper explosion limits of organic acids were predicted by using the heat of combustion and chemical stoichiometric coefficients. The values calculated by the proposed equations agreed with literature data within a few percent. From the given results, using the proposed methodology, it is possible to predict the explosion limits of the other organic acids.

Properties Evaluation of Thermochromic Gel Compounds for Detecting Overheating (과열감지용 열변색 겔성형체의 특성 평가)

  • Kim, Jeong-Hun;Cho, Myoung-Ho;Kang, Young-Goo
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.61-66
    • /
    • 2008
  • In this research, gel compounds containing thermochromic ingredients were manufactured and evaluated to prevent the transition hazards of fire and explosion, which they are one of the methods for detecting abnormal conditions caused by overheating of special materials early. And also, compounds of viscoelastic and brushing types were manufactured as the kind and content of raw materials, and manufacturing process to enlarge the application for overheat-detecting targets. Test methods were conducted as chromism test, viscosity profile, starting time of thermochromism, and FT-IR analysis. Thermochromic gel materials exhibit chromism properties that can detect abnormal conditions effectively, and then they are possible to various applications.

Prediction of Upper Explosion Limits (UEL) of Acids and Ketones by Using Setaflash Tester (Setaflash 장치를 이용한 산류와 케톤류의 폭발상한계 예측)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.114-119
    • /
    • 2011
  • Explosion limit and flash point are the major combustion properties used to determine the fire and explosion hazards of the flammable substances. In this study, in order to predict upper explosion limits (UEL) for acids and ketones, the upper flash point of these were measured under the VLE (vaporliquid equilibrium) state by using Setaflash closed cup tester (ASTM D3278). The UELs calculated by Antoine equation by using the experimental upper flash point are usually lower than the several reported UELs. From the given results, using the proposed experimental and predicted method, it is possible to research the upper explosion limits of the other flammable substances.

A Numerical Study for Fire Safety Evaluation of the Multi-story Residential Buildings -The Effects of the Openings of Stairwell on Fire Characteristics- (다세대주택의 화재안전평가에 대한 수치해석 연구 -계단실 개구부의 개폐가 화재특성에 미치는 영향-)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.15-23
    • /
    • 2007
  • In the events of a fire in the residential building, highly flammable polyurethane foam sofa produce toxic smokes. In this type of fire, the residents of the building can be gotten into the difficulties of evacuating from the fire places or may be to death due to a lot of hot toxic gases. In this study, CFD simulations were carried out to study the effects of the openings of stairwell on the fire characteristics of fire room and stairwell. Also, analysis of fire hazard based on the tenability limits of fire and FED(fractional effective dose) was performed to evaluate the life safety of the residents of the building. In the fire room, maximum temperature was about $290^{\circ}C$, maximum CO concentration was about 4,740 ppm, and the time to incapacitation of residents in fire room was about t=144 s. In the stairwell, temperature and CO concentration in the condition of openings to be open were even lower than those in it to be closed. Time to the tenability limit with respect to smoke visibility in the stairwell with openings, which was open, was shorter than that of it without openings to be open. It has been shown from this study that opening the stairwell openings is able to decrease the fire hazards to the life safety in the multi-story residential building fire.