• 제목/요약/키워드: fire hazards

검색결과 212건 처리시간 0.02초

Methanol, Ethanol, 1-propanol 그리고 Toluene 이성분 혼합계에 대한 인화점 측정 (Measurement of Flash Point for Binary Mixtures of Methanol, Ethanol, 1-propanol and Toluene)

  • 황인찬;김선우;인세진
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.1-6
    • /
    • 2018
  • 인화점은 산업현장에서 액체의 화재 및 폭발 위험을 결정하는데 사용되는 가장 중요한 변수 중 하나로써 가연성 물질의 화재 위험성을 나타내는 지표이며 안정성 평가에 많이 사용되고 있다. 따라서 본 연구는 다양한 산업에서 용매로 사용되는 이성분계 혼합물 중 {methanol+toluene}, {ethanol+toluene} 그리고 {1-propanol+toluene}에 대한 인화점을 SETA 밀폐식 인화점 측정기를 이용하여 측정하였다. 각 이성분계 혼합물에 대한 인화점을 예측하기 위해 Raoult's의 법칙, Wilson, NRTL 및 UNIQUAC 파라미터를 이용하였고 실험 결과와 비교하였다. Raoult's의 법칙을 제외한 비교 결과, 모든 예측값과 실험값은 유사한 값을 보였고 편차가 1.69 K이내의 결과를 보였다.

Modeling and simulation of large crowd evacuation in hazard-impacted environments

  • Datta, Songjukta;Behzadan, Amir H.
    • Advances in Computational Design
    • /
    • 제4권2호
    • /
    • pp.91-118
    • /
    • 2019
  • Every year, many people are severely injured or lose their lives in accidents such as fire, chemical spill, public pandemonium, school shooting, and workplace violence. Research indicates that the fate of people in an emergency situation involving one or more hazards depends not only on the design of the space (e.g., residential building, industrial facility, shopping mall, sports stadium, school, concert hall) in which the incident occurs, but also on a host of other factors including but not limited to (a) occupants' characteristics, (b) level of familiarity with and cognition of the surroundings, and (c) effectiveness of hazard intervention systems. In this paper, we present EVAQ, a simulation framework for modeling large crowd evacuation by taking into account occupants' behaviors and interactions during an emergency. In particular, human's personal (i.e., age, gender, disability) and interpersonal (i.e., group behavior and interactions) attributes are parameterized in a hazard-impacted environment. In addition, different hazard types (e.g., fire, lone wolf attacker) and propagation patterns, as well as intervention schemes (simulating building repellent systems, firefighters, law enforcement) are modeled. Next, the application of EVAQ to crowd egress planning in an airport terminal under human attack, and a shopping mall in fire emergency are presented and results are discussed. Finally, a validation test is performed using real world data from a past building fire incident to assess the reliability and integrity of EVAQ in comparison with existing evacuation modeling tools.

FRA(Fire Risk Assessment)기법을 이용한 화학공장의 Fire Protection에 관한 연구 (A Study on Fire Protection of Chemical Plants Using FRA (Fire Risk Assessment) Method)

  • 한승훈;류병태;태찬호;채충근;고재욱
    • 한국가스학회지
    • /
    • 제20권5호
    • /
    • pp.17-26
    • /
    • 2016
  • 현대 화학플랜트 및 석유 가스 산업 시설은 다양한 잠재위험으로 인하여 위험물질의 누출 및 화재가 빈번히 발생하고 있다. 그 중 특히 화재는 직접적인 화염의 접촉 또는 복사열로 인하여 인명피해는 물론 건물, 설비에 대한 피해 발생으로 domino effect가 발생하여 2차, 3차 피해까지도 발생하기도 한다. 따라서 본 연구에서는 발생가능한 화재를 파악하여 사고피해영향과 빈도를 낮추어 화재 위험성을 관리하는 FRA(Fire Risk Assessment)기법의 절차를 제시하였으며, 사고피해영향으로 화염의 직접적인 접촉과 복사열로 인한 주요건물(제어실, 창고, 변전소)의 물리적 특성이 변형되는 시간을 고려하였다. 사례연구를 통하여 수행한 FRA기법으로 국내외 화학공장의 위험성을 경감시킬 수 있었으며, Protection 설정을 통한 사고의 빈도와 피해영향의 감소를 정량적으로 파악할 수 있었다.

보육시설의 피난안전 관련 주요 기준 분석 및 실태조사에 관한 연구 (A Study on the Major Standards and Actual Conditions of Evacuation Safety in Child Care Facility)

  • 박재성
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.93-102
    • /
    • 2009
  • 최근 보육시설의 확충과 보육환경의 개선, 보육서비스 질 향상에 대한 사회적 욕구는 급속히 증가하고 있으며, 특히 화재 등으로부터 안전환경 확보가 범국가적 이슈로 대두되고 있다. 보육시설은 영유아 등 재실자의 대부분이 피난능력이 떨어지는 재해약자로 구성되어 건물 내 설치층수, 피난시설의 설치 적정성 등이 피난안전을 좌우하는 중요한 요소이다. 본 연구에서는 보육시설 설치현황, 국내외 관련 기준의 비교분석, 피난 관련 시설의 실태조사 등을 통하여 보육시설 피난안전성 측면에서의 문제점과 개선요소를 파악하였다. 그 결과 화재안전 관련 법규정의 체계화, 비상재해대비시설의 설치기준 및 관리에 대한 소방기관과의 연계, 스프링클러 등 보다 강화된 소방설비 설치규정의 개선, 화재위험시설과 동일 건물 내 설치금지 등이 필요한 것으로 분석되었다.

재난 취약성 분석에 관한 사례연구(N공단의 화재·폭발을 중심으로) (Case Study on the Analysis of Disaster Vulnerabilities (Focused on the Fire & Explosion in the N-Industrial Complex))

  • 하각천
    • 한국안전학회지
    • /
    • 제36권2호
    • /
    • pp.94-100
    • /
    • 2021
  • In general, the industrial complex is a place where factories of various industries are concentrated. It is only as efficient as it is designed. However, the risks vary as there are various industries. These features are also associated with various types of disasters. The dangers of natural disasters such as a typhoon, flood, and earthquake, as well as fire and explosions, are also latent. Many of these risks can make stable production and business activities difficult, resulting in massive direct and indirect damage. In particular, decades after its establishment, the vulnerabilities increase even more as aging and small businesses are considered. In this sense, it is significant to assess the vulnerability of the industrial complex. Thus analysing fire and explosion hazards as stage 1 of the vulnerability evaluation for the major potential disasters for the industrial complex. First, fire vulnerabilities were analyzed quantitatively. It is displayed in blocks for each company. The assessment block status and the fire vulnerability rating status were conducted by applying the five-step criteria. Level A is the highest potential risk step and E is the lowest step. Level A was 11.8% in 20 blocks, level B was 22.5% in 38 blocks, level C was 25.4% in 43 blocks, level D was 26.0% in 44 blocks, and level E was 14.2% in 24 blocks. Levels A and B with high fire vulnerabilities were analyzed at 34.3%. Secondly, the vulnerability for an explosion was quantitatively analyzed. Explosive vulnerabilities were analyzed at 4.7% for level A with 8 blocks, 3.0% for level B with 5, 1.8% for level C with 3, 4.7% for level D with 8, and 85.8% for level E with 145. Levels A and B, which are highly vulnerable to explosions, were 7.7 %. Thirdly, the overall vulnerability can be assessed by adding disaster vulnerabilities to make future assessments. Moreover, it can also assist in efficient safety and disaster management by visually mapping quantified data. This will also be used for the integrated control center of the N-Industrial Complex, which is currently being installed.

바이오디젤 혼합물의 함량변화에 따른 열적 특성에 대한 실험적인 연구 (Experimental Study on the Thermal Characteristics According to the Content Change of Biodiesel Mixture)

  • 김주석;고재선
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.532-544
    • /
    • 2023
  • 연구목적: 신규로 사용되는 바이오연료를 기존 연료와 혼합하여 사용하는 경우 발생하는 위험성과 물성 변화를 열분석 방법(DSC, TGA)을 사용하여 화학 화재의 원인물질의 위험성을 확인하고, 평가할 방법과 그에 따른 물질의 위험성 관련 데이터를 확보함으로써 화재 원인 감식과 감정에 활용하기 위함이다. 연구방법: 본 실험에 사용된 연구 방법으로는 시차주사열량계(DSC : Differential Scanning Calorimeter)에 의하여 피크의 위치, 모양, 개수, 피크의 면적으로부터 열량 변화의 정량적인 정보를 통하여 열유속 차이(Difference in heat flux)를 측정하였고, 열중량분석(TGA : Analyzer)을 시행함으로써 특정한 온도에서 분해열 등에 의해 발생한 무게 변화를 연속적으로 측정하였다. 연구결과: 먼저 열 유속의 그래프에서 물질의 끓는점과 물질이 가지고 있는 고유 특성치 또는 분해에 필요한 에너지를 확인할 수 있다. 둘째 바이오디젤의 함량이 증가할수록 많은 피크를 확인 할 수 있었다. 셋째 비점이 낮은 물질들이 함유하고 있다는 것을 분석 결과로 확인할 수 있었다. 결론: 현재 새로운 에너지원으로 사용되고 있는 바이오디젤의 위험성을 다양한 물리·화학적 분석기법(DSC+TGA)을 통하여 사용함으로써 물질의 물적 위험성을 평가할 수 있음을 보여주었다. 아울러 본 연구의 시험방법별 차이의 비교와 실험에 대한 노하우를 축적하고 활용한다면 향후 위험물의 물성 연구와 물질 위험성 평가 연구에 있어 도움이 되리라 기대한다.

순수 가연성액쳬의 인화점추산 -I. 알코올- (Estimation of Flash Points of Pure Flammable Liquids -I. Alcohols-)

  • 하동명;이수경;김문갑
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.39-43
    • /
    • 1993
  • The flash points of flammable liquids are a fundamental and important property relative to fire and explosion hazards. A new estimation method, based on statistics (mutiple regression analysis), is being developed for the prediction of flash points of pure flammable liquids by means of computer simulation. This method has been applied to alcohol liquids. The proposed method has proved to be the general method for predicting the flash points of alcohol liquids.

  • PDF

화학물질 취급시설의 안전관리 합리화 방안 연구: 건축물 내화기준 중심 (A study on the Rationalization of Safety Management in Chemical Facilities: Focused on Architecture Fire Resistance Standards)

  • 이은별;유병태
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.91-97
    • /
    • 2019
  • 국내 화학물질 안전관리는 환경부의 화학물질관리법이 기본이 되어 관리되고 있다. 그 중에서도 취급시설의 설치 및 관리기준을 강화하여 관리하고 있는데, 타 법과의 상충, 시설 규모 및 물질 특성 미반영 등으로 인한 문제점들이 노출되었다. 본 연구에서는 이러한 취급시설 기준 중 건축물 내화기준에 대해 보다 현실적이면서 합리적인 개선 방안을 마련하고자 하였다. 이를 위해 국내 유사 화학물질 취급시설 안전관리 법령의 건축물 내화기준을 비교하였으며, 환경부 화학물질안전원 국민신문고를 통해 접수된 취급시설 기준 관련 민원 2220건 중 대표 민원 사례를 통해 주요 문제점을 파악하였다. 마지막으로 화학물질관리법상 취급시설의 규모와 물질의 종류를 구체화하여 건축물 내화기준을 적용하는 개선 방안을 제시하였다. 향후, 본 연구 결과는 환경 유해성을 고려한 화학물질관리법의 기본 취지에 부합하고, 산업계에도 현실적으로 적용될 수 있는 합리적인 기준마련에 기여할 수 있을 것으로 기대된다.

화재 시 일체형 방화셔터 작동유무에 따른 초등학생의 피난특성 (The Evacuation Characteristics of Elementary School Student According to Working of Single Unit Fireproof Shutter for Fires)

  • 이승철;홍이표;김상일
    • 한국화재소방학회논문지
    • /
    • 제27권4호
    • /
    • pp.35-40
    • /
    • 2013
  • 본 연구는 일체형 방화셔터가 설치된 초등학교 학생의 피난특성에 관한 연구이다. 구체적인 방법으로 일체형 방화셔터를 포함한 방화셔터 전반에 대한 기초 자료를 수집 검토하였으며, 초등학교에 설치된 일체형 방화셔터 작동 유무에 따른 재실자 피난특성을 비교 분석하였다. 화재 모의실험 결과, 일체형 방화셔터 미작동시 최종 대피완료 시간은 130초이며, 일체형 방화셔터 작동 시에는 190초가 소요되었다. 그리고 일체형 방화셔터 작동 시 피난대피 상황에서 초등학생들이 셔터내의 출입문을 열지 못하는 상황이 발생되었다. 이러한 상황을 고려한다면 일체형 방화셔터 작동 시 최종피난 완료시간은 상당히 지연될 수 있고, 많은 학생들이 화재위험에 노출될 수 있다. 따라서 향후 일체형 방화셔터 출입문 개폐력에 대한 연구가 반드시 진행되어야 할 것으로 생각된다.

산류(Acids)의 인화점과 최소자연발화온도의 신뢰성 고찰 (Investigation of Reliability of Flash Points and Autoignition Temperatures of Acids)

  • 하동명
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.42-47
    • /
    • 2009
  • The flash point and the AIT(auto-ignition temperature) are the most important combustible properties used to determine the potential for the fire and explosion hazards of flammable material. In order to know the accuracy of data in MSDS(Material Safety Data Sheet), the flash point of n-acids were measured by using Pensky-Martens closed cup tester(ASTM D93), Setaflash closed cup tester(ASTM D3278), Tag open cup tester(ASTM D1310) and Cleveland open cup tester(ASTM D92). Also, the AIT of n-acids were measured by using ASTM E659-78 tester. The measured the flash points and the AIT were compared with literatures and MSDS in KOSHA. The measured the flash points and the AIT were different from those in literatures and MSDS. Therefore, This paper shows that it is needed to investigate the MSDS compatibility of n-acids for the fire safety objectives.