• Title/Summary/Keyword: fire fuel

Search Result 426, Processing Time 0.026 seconds

Effects of Spray Characteristics of Water Mist on The Extinction of a Liquid Pool Fire (분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향)

  • Kim, Ho-Young;Oh, Sang-Youp;Chung, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1591-1599
    • /
    • 2004
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is a small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is l15∼180${\mu}{\textrm}{m}$ with nozzle A and 130∼190${\mu}{\textrm}{m}$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of $O_2$ concentration.

A Study on the Flame Behavior of Whirl Eire and Pool Fire (Whirl Fire와 Pool fire의 화염 거동에 관한 연구)

  • Oh Kyu-Hyung;Kang Youn-Ok;Lee Sung-Eun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.45-50
    • /
    • 2004
  • 4-panel of 1m height and 45cm width were fixed on the $40cm{\times}40cm$ bottom plate and the opening of the panel comer was 5cm. Diameter of stainless vessel is loom and its height is 2cm and it located at the center of the bottom plate. 78mL liquid fuel was filled in the vessel and its depth was 1cm. Flame temperature was measured with K type thermocouple, and radiation heat of flame was measured with heat flux meter. Flame height and its behavior was visualized with video camera. and mass burning rate was measured by fuel combustion time. According to the development of fire, flame swirling was begin. From the experiment the mass burning rate was larger and the height of flame was higher than the usual pool fire flame. Flame temperature and heat flux also increased far more than the pool fire. Consequently the swirling air flow through the openings between the panel and thermal buoyance contribute to increase of heat release rate, flame length and mass burning rate.

Analysis of Fuel Moisture Contents Change after Precipitation in the Pine tree stand during Forest Fire Period in the East sea region (영동지역 소나무림에서 강우 후 임내 연료습도 변화분석)

  • Lee, Si-Young;Lee, Myung-Woog;Kwon, Chun-Geun;Yeom, Chan-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.149-152
    • /
    • 2008
  • This study is the result between the variation of fuel moisture and the risk of forest fire through measuring the change of moisture containing ratio on-site and its average analysis for fallen leaves layer, humus layer, and soil layer in the forest. The measurement was performed on six days from the day after a rainfall. The fuel moisture on-site was measured on the day when the accumulated rainfall was above 5.0mm, and the measurements was 2 times in spring and 1 time in fall. From the pine forest which were distributed around Samcheok and Donghae in Kangwondo, three regions were selected by loose, medium, and dense forest density, and the fuel moisture was measured on fallen leaves layer, humus layer, and soil layer in the forest. for six days from the day after a rainfall. The study showed that the moisture containing ratio converged on 3 - 4 days in spring and fall for fallen leaves layer, and the convergence was made more than six days in spring and fall for the humus layer. In the other case of soil layer, the variation of moisture containing ratio after rainfall was not distinguishable regardless of season.

  • PDF

The Effects of Combustion Products Dilution and Wall Temperature on the Ignition of Methane Fuel (메탄연료의 점화특성에 미치는 연소 생성물 희석 및 벽면온도의 영향)

  • Song, Keum-Mi;Oh, Chang-Bo
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.9-15
    • /
    • 2012
  • The ignition characteristics in a confined axisymmetric coflow $CH_4$ jet were investigated numerically with the Fire Dynamics Simulator(FDS). The $CH_4$ fuel stream was diluted with main combustion product gases, such as $O_2$, $N_2$, CO, $CO_2$, and $H_2O$, and the mixed fuel stream was heated up to the sufficient temperature where a supplying fuel stream can be ignited. For the calculation of chemical reaction in the simulation, a 2-step global finite chemistry model was considered. Boundary condition for confined wall was optimized by investigating the effects of wall temperature on the ignition characteristics of fuel stream. In addition, the effects of composition of diluents in the fuel stream and fuel stream temperature on the ignition of fuel steam were investigated. The ignition characteristics of $CH_4$ stream with diluents were very sensitive to the wall temperature, composition of diluents in the fuel stream and fuel stream temperature.

Numerical analysis on the rapid fire suppression using a water mist nozzle in a fire compartment with a door opening

  • Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.410-423
    • /
    • 2019
  • Fire suppression using a water mist nozzle directly above an n-Heptane pool in a fire compartment with a door opening was numerically investigated using the Fire Dynamics Simulator (FDS) for the purpose of application in nuclear power plants. Input parameters for the numerical simulation were determined by experimental measurements. Water mist was activated 10 s after the fire began. The sensitivity analysis was conducted for three input parameters: total number of cubic cells of 6032-2,926,400, droplets per second of 1000-500,000, and extinguishing coefficient of 0-100. In a new simple calibration method of this study, the extinguishing coefficient yielding the fire suppression time closest to that measured by experiments was found for use as the FDS simulation input value. When the water mist jet flow made contact with the developed fire, the heat release rate instantaneously increased, and then rapidly decreased. This phenomenon occurred with a displacement of the flame near the liquid fuel pool. Changing the configuration of the door opening with different aspect ratios and opening ratios had impact on the maximum value of the heat release rate due to the flame displacement.

The Combustion Characteristics of Biodiesel/Diesel Fuel Blends (바이오디젤/디젤 혼합 연료유의 연소 특성)

  • Song, Young-Ho;Ha, Dong-Myeong;Chung, Kook-Sam
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.35-40
    • /
    • 2008
  • As the environmental pollution by the drastic increase of vehicles becomes one of the social major concerns, the method of reducing the harmful exhaust emission is being the subject of interest. Utilization of used frying oil as a raw material for biodiesel production is helpful not only for the stable supply of raw materials but also costing down the biodiesel price. This study was conducted the measurement the combustion and thermal characteristics with mixing ratio of biodiesel/diesel fuel. In this study, flash points and fire points were measured by using Tag Closed cup apparatus and Cleveland open cup apparatus. As the result, flash points, fire points and AIT increased with percentage of more contained biodiesel.

  • PDF

The Study on Slope and Wind of Surface Fire Fuel (지표화 연료의 경사 및 풍속에 관한 연구)

  • Kim, Jang-Hwan;Kim, Eung-Sik;Lee, Myung-Bo;Kim, Dong-Hyun;Park, Hyung-Ju
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.55-60
    • /
    • 2008
  • 본 연구에서는 침엽수종인 소나무 낙엽과 활엽수종인 굴참나무 낙엽을 실내 모의실험장치(Fuel bed)를 이용하였다. 연소구간은 1m이며, 낙엽의 두께는 5cm로 일정하게 유지하였으며, 경사도 $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$의 경사도에 대한 실험과 연소구간에서의 풍속은 이들의 대표값으로 평균 풍속값은 다음과 같이 0.75m/s(1m/s), 1.4m/s(2m/s), 2.5m/s(3m/s)로 실 측하여 실험하였다. 따라서 본 연구에서는 실내 모의실험장치(Fuel bed)를 이용하여 경사도에 대한 실험과 평균풍속 실험을 통하여 임내 연료의 지표화에서 수관화로의 전이특성을 구명하고 산불피해 저감에 기여코자 한다.

  • PDF

Semi-numerical Study on the Flame Tilt Equation due to Wind on the Surface Fire in Forest Fire (산불 지표화에서의 바람에 의한 화염각 변화 산정식 도출에 관한 준-수치해석 연구)

  • Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.90-95
    • /
    • 2009
  • The wind is very important factor in forest fire spread. Flame spread has a change through wind pattern change in forest fire. In order to analyze the forest fire flame spread rate, change of flame tilt depending on wind may be considering first. This is be cause the flame spread rate varies by the flame tilt changed due to transfer of heat. Especially, as wind speed grow, flame gets closer to surface, heat transfer ratio increase, virgin fuel bed reaches ignition temperature more rapidly, and flame moves faster. This study deduces, through experiment and physical figure analysis, relations on the change behavior of flame tilt due to wind. The value of flame tilt angle calculated from the equation and the experiment value showed average error angle of $3.3^{\circ}$, which is relatively smaller than results of previous studies that used other coefficient. Froude number coefficient A can be calculated in the method provided in this research for estimation of flame tilt angle of virgin fuel bed with varying thermal properties. The research finding is expected to be applied to future studies on flame spread through numerical analysis of heat transfer.