• Title/Summary/Keyword: fire environment

Search Result 1,068, Processing Time 0.022 seconds

Fire Characteristics for Spill Rate of Light oil and Methanol (경유와 메탄올의 유출속도에 따른 화재특성)

  • Lee, Jung Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.54-60
    • /
    • 2016
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate. Depending on spill rate(30, 60, 90 and $120{\ell}/min$) and the longer the duration of the flame important factors for the internal temperature of tank lorry rise was found. Road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

The "Warm Zone" Cases: Environmental Monitoring Immediately Outside the Fire Incident Response Arena by Firefighters

  • Caban-Martinez, Alberto J.;Kropa, Bob;Niemczyk, Neal;Moore, Kevin J.;Baum, Jeramy;Solle, Natasha Schaefer;Sterling, David A.;Kobetz, Erin N.
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.352-355
    • /
    • 2018
  • Hazardous work zones (i.e., hot, warm, and cold) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe warm zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the "warm zone" of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the warm zone but also include respiratory protection to provide adequate safety from toxic exposures in the warm zone.

The fire resistance performance test methods and equipment overview on the marine plant (해양플랜트 기자재의 화재저항 성능에 관한 시험방법 및 설비의 개요)

  • Jeon, Jun-Pyo;Kim, Jung-Sik;Choi, Tai-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.113-116
    • /
    • 2012
  • 플랜트란 산업 기계, 전기 통신 기계등 여러 가지를 생산하는 공장을 의미하고 있다. 해양플랜트는 바다위에 설치된 시설이라고 볼 수 있으며 주로 원유 및 가스를 채취하여 시중에서 사용할 수 있도록 정유공정까지 거치는 대규모 설비라고 할 수 있다. 따라서 가연성 물질을 생산, 적재함으로 화재 및 폭발의 위험성이 상존하며 화재가 발생하면 인화성 물질로 인한 대규모 화재와 폭발로 인하여 인명과 재산피해의 규모 또한 가름하기가 어렵다. 본 논문에서는 해양플랜트 화재시 화재와 폭발 두 가지 위험성 중 제트화재에 저항을 가지는 기자재를 평가할 수 있는 ISO 22899-1 시험방법과 설비에 대하여 설명하고자 한다.

  • PDF

Results of a Round-Robin Test for the Draft International Standard on FT-IR Gas Analysis of Fire Effluents from a Cone Calorimeter (콘칼로리미터 연소가스 FT-IR 분석을 위한 국제표준 초안의 비교시험 결과분석)

  • Choi, Jung-Min;Park, Kye-Won;Jeong, Jae-Gun
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.1-8
    • /
    • 2019
  • The international standard for FT-IR gas analysis of fire effluents in ISO 5660-1 cone calorimeter has been being developed in ISO TC 92. A comparison of the round-robin test of WD 21397 was conducted with six participating laboratories in 2018. The test specimens were PMMA, rigid PU foam board, and PVC flooring. The measurement quantities were the time-to-ignition, peak heat release rate, total heat release, and effective heat of combustion for a cone calorimeter test and peak gas concentration, gas generation, and gas yield for FT-IR gas analysis. No outliers were identified. For the cone calorimeter quantities, the repeatability and reproducibility were 1.5% and 9.8%, respectively. For FT-IR gas analysis, the repeatability and reproducibility was 12.9% and 27.9%, respectively.

DATA BASE SYSTEM DEVELOPMENT AND STATISTICAL ANALYSIS OF EIR3 ACCIDENTS OF SEVERAL COUNTRIES

  • Kim, In-Tae;Kim, In-Won;Song, Hee-Oeul
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.319-326
    • /
    • 1997
  • The fire accident cases of several countries such as Korea, Japan, United States, etc., were collected and compared statistically. The trends of fire accidents in several countries will help us establish detailed plans for fire protection and reduce the possible fire accidents in the future. For construction of data base system, the program FADS was developed, which is operable in Windows environment.

  • PDF

Numerical Study on the Effect of Range Surrounding Environment on Detecting Time for Cooking Oil Fire in Kitchen (주방내 조리용 기름 화재 발생시 레인지 주변 환경이 감지 시간에 미치는 영향에 대한 수치해석적 연구)

  • Lee, Jin-Woo;Ko, Gwon-Hyun;Ryou, Hong-Sun;Jang, Yong-Jun;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.134-139
    • /
    • 2010
  • According to the "Yearbook of disaster response, fire safety and fire statistics (NEMA: National Emergency Management Agency)", approximately 34% of all fire is interior fire such as hotel, restaurant and residence and more than 53% of which is occurring in the kitchen. The evaluation of fire extinguishing system in the kitchen is performed in accordance with the "Korea Fire Equipment Inspection Standard (KOFEIS 0101-1)" which is using one environmental condition. However, only using one environmental condition is not enough to evaluate the performance of the automatic fire extinguisher in kitchen fire. So the study of fire detecting characteristic about various environmental condition needs. In this study, the numerical analysis is carried out about detecting time characteristic for various range's surrounding environment. As a result, it showed up to 100 s difference in the detection time depending on the position of the range. And detecting time also showed difference for on-off hood operation. From this results, it can be verify and improve the evaluation standard for the fire extinguishing system in kitchen fire.

The Development of Virtual Fire Control System Considering Operational Environment of Helicopter (헬기 운용환경을 고려한 가상 사격 통제 시스템 개발)

  • Kim, Woosik;Lee, Dongho;Jang, Indong;Park, Hanjoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.448-455
    • /
    • 2014
  • Virtual Fire Control System(VFCS) in attack helicopter is developed. VFCS is comprised of multifunction display, store management computer, mission computer, target acquisition and designation system, mission planning system, weapon simulator and flight simulator. Weapon engagement process under the operational environment of helicopter was considered by using the VFCS. We considered hellfire missile, tow missile, unguided rocket and turret gun. The results of this study will be utilized efficiently on integrated fire control system SIL(System Integration Lab.) in attack helicopter.