• Title/Summary/Keyword: fire environment

Search Result 1,068, Processing Time 0.028 seconds

A Fundamental Study on the Development of Fire Resistance Filling of Friendly Environment Using Aerated Concrete (기포콘크리트를 이용한 친환경 내화충전제개발에 관한 기초적 연구)

  • Lee, jong-il;Lim, Nam-Gi
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.119-126
    • /
    • 2007
  • In this study, we processed two procedures of application test of filler for fire-resistance utility that are new application methods of aerated concrete and properties test of aerated concrete according to mixing ratio because we investigated the better use of aerated concrete as filler for fireproof safety and we proposed basic data about standardization of mixing of aerated concrete. We measured flow and volume change of aerated concrete. And if its volume doesn't change, we added measuring unit weight and compressive strength. To test application of aerated concrete as filler for fireproof safety, we filled up aerated concrete to fireproof safety according to suitable mixing ratio. Then we measured maximum temperature of inner part of fireproof safety in accordance with the standard test of fireproof. According to the results, aerated concrete as filler for fireproof safety could be possibly used. So when we make aerated concrete, we should consider using an adding agent as well as a foaming agent.

A Case Study of Hybrid Air Conditioning and Ventilation System (환기 병용형 냉난방 시스템 설계 및 현장 적용 사례 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju;Shin, Hyun-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.89-94
    • /
    • 2008
  • In this study it was evaluated that hybrid air conditioning and ventilation system to reduce energy consumption and keep on comfortable indoor environment in an underground shopping center. Room temperature by hybrid HAVC system was controled as $1.8{\sim}2.1^{\circ}C$ low and indoor humidity was controled as $4.1{\sim}5.0%RH$ low, and response was fast in $2.0{\sim}2.5$ times compared with conventional system. And also transportation efficiency of hybrid HVAC system was improved in about 27%, and total energy consumption rate of hybrid HVAC system is decreased in 16% compared with conventional system.

  • PDF

A Study on the Application of NOAA/AVHRR Data -Analysis of cloud top and surface temperature,albedo,sea surface temperature, vegetation index, forest fire and flood- (NOAA/AVHRR 자료 응용기법 연구 - 운정.지표온도, 반사도, 해수면 온도, 식생지수, 산불, 홍수 분석 -)

  • 이미선;서애숙;이충기
    • Korean Journal of Remote Sensing
    • /
    • v.12 no.1
    • /
    • pp.60-80
    • /
    • 1996
  • AVHRR(Advanced Very High Resolution Radiometer) on NOAA satellite provides data in five spectral, one in visible range, one in near infrared and three in thermal range. In this paper, application of NOAA/AVHRR data is studied for environment monitoring such as cloud top temperature, surface temperature, albedo, sea surface temperature, vegetation index, forest fire, flood, snow cover and so on. The analyses for cloud top temperature, surface temperature, albedo, sea surface temperature, vegetation index and forest fire showed reasonable agreement. But monitoring for flood and snow cover was uneasy due to the limitations such as cloud contamination, low spatial resolution. So this research had only simple purpose to identify well-defined waterbody for dynamic monitoring of flood. Based on development of these basic algorithms, we have a plan to further reseach for environment monitoring using AVHRR data.

A Study on Fire Protection in Nuclear Power Plants and Application of the Code and Standards for Fire Protection Systems (원자력발전소 화재방호와 소방시설 기술기준 적용에 대한 고찰)

  • Kim, Wee-Kyong;Jeong, Kee-Sin
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.38-44
    • /
    • 2012
  • The purpose of fire protection for the nuclear power plants (NPPs) is to ensure safe shutdown state of the reactor, to minimize the release of radioactive materials to the environment, to provide physical safety of the on-site personnel, and to limit the property damage. Fire protection and extinguishing equipments are one of the important protection measures based on the defense-in-depth concept, which can promptly detect and control and extinguish those fires that do occur, thereby limiting fire damage. However, a separate evaluation process might be additionally necessary for the construction permit and operating license because the fire protection laws of the NEMA for installation standards of the fire protection systems is not fully characterized for the NPPs. It is also not easy to implement the regulations such as the performance based design concept for fire protection system of the NPPs which are characterized for a relatively low density of employee. This study suggests a guideline for the improvement of the technical standards for fire protection systems of the NPPs by evaluating the fundamental problems drawn by reviewing laws and regulatory guides relevant to fire protection and by evaluating the applicability of the KEPIC FPN in domestic nuclear power plants.

A Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities (효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구)

  • Son, Gae-Seong;Choi, Ji-Hun;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.161-169
    • /
    • 2015
  • A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.

The Study of Fire Suppression Capability of Sprinkler System for Wooden Cultural Properties (스프링클러 소화설비의 목조문화재 소화성능에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu;Kim, Dong-Chul
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.51-57
    • /
    • 2011
  • The domestic wooden cultural properties applied to the sprinkler extinguishing system was confirmed extinguishing performance through fire experiments. Consists of wooden cultural properties of a fire, a flammable material is vulnerable in terms of. The scale of fire will occur to vary appearance of the initial fire in case of arson. Sprinkler nozzles of the characteristics, the discharging pressure is 1 bar and the flow rate is 80 lpm, applied in this experiment. Fire performance experiments were tested in two separated in each of the scale of the fire and cultural properties. Fire extinguishing performance test results was low in high ceilings and two or more units of the fire scale. Fire growth environment of the actual wooden cultural properties to experimental models when you consider that it is more vulnerable, sprinkler extinguishing system is required sufficient verification in order to apply fire protection of the wooden cultural properties.

Construction Of Fire Resistant Forest Belts (산불피해를 줄일 수 있는 조림방안 - 내화수림대 조성 -)

  • Lim, Joo-Hoon
    • Journal of the Korean Professional Engineers Association
    • /
    • v.38 no.3
    • /
    • pp.1-5
    • /
    • 2005
  • As a method of anti-fire construction in forest region it is proposed to build fuelbreak(vegetated firebreak). Fuelbreak can separate the large area conifer forest into smell parts combined with natural firebreaks. Fuelbreaks can prevent forest fire effectively and also have other functions benefiting the forest ecosystem and environment. 3 kinds of construction skills are introduced for the silviculture technique to build fuelbreaks. And it is proposed to build the firebreaks network in national scale.

  • PDF

Flame and Smoke Detection Method for Early and Real-Time Detection of Tunnel Fire (터널 화재의 실시간 조기 탐지를 위한 화염 및 연기 검출 기법)

  • Lee, Byoung-Moo;Han, Dong-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.4
    • /
    • pp.59-70
    • /
    • 2008
  • In this paper, we proposed image processing technique for automatic real-time fire and smoke detection in tunnel environment. To avoid the large scale of damage of fire occurred in variety environments, it is purposeful to propose many studies to minimize and to discover the incident as fast as possible. But we need new specific algorithm because tunnel environment is quite different and it is difficult to apply previous fire detection algorithm to tunnel environment. Therefore, in this paper, we proposed specific algorithm which can be applied in tunnel environment. To minimize false detection in tunnel we used color and motion information. And it is possible to detect exact position in early stage with detection, test, verification procedures. In addition, by comparing properties of each algorithm throughout experiment, we have proved the validity and efficiency of proposed algorithm.

국내 방폭전기 안전 기준 제정 배경 및 방폭지역 구분 요령

  • Jeong, Jae-Jong
    • Fire Protection Technology
    • /
    • s.15
    • /
    • pp.22-27
    • /
    • 1993
  • The classification of hazardous area is a method of analysing and classifying the environment where explosive gas or vapour atmosphere may be expected to be present. The object of area classification is to enable the proper selection and installation of electical apparatus and other equipments. This report is intended to serve a general reference about the classification procedure of hazardous area with explanations of related Korean Standard.

  • PDF

A change of soil properties and forest vegetation present in burned areas in Geyjoksan, Daejeon metropolitan city (대전광역시 계족산 산화지의 토양 변화와 식생 현황)

  • Lee, Hang-Goo;Park, Gwan-Soo;Lee, Sang-Jin;Kim, Kil-Nam;Park, Beom-Hwan;Ko, Young-Woong;Yoon, Jun-Young;Kim, Hyoun-Sook;Lee, Sang-Hyuk;Kang, Kil-Nam
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.25-30
    • /
    • 2011
  • This study was conducted to investigate changes on burned areas after a forest fire in Geyjoksan which occurred in April 2000. Both soil physicochemical properties and vegetation present were analyzed in burned and unburned sites of pinus densiflora according to two slope aspects(south and north-facing slopes). The results of the analysis are as follows. The appearance species of vegetation were 21, 15 and 18 for burned site, burned site-1 and burned site-2 of pinus densiflora community respectively, indicating that the occurrence of forest fire and slope aspects affect vegetation appearance. The pH values at 0~10cm soil depth of unburned and burned sites of pinus densiflora community were 5.04 and 5.12 respectively with no significant difference between them. Mean organic matter, total nitrogen and available P also had no significant difference. This results indicate that the forest recover its former pH, total nitrogen, mean organic matter and available P over time after a forest fire. North-facing slope had relatively higher soil water content thus implying that its pH values of soil lower than south-facing slope. On the other hand, south-facing slope had high organic matter and available P content of soil as compared to north-facing slope. With south facing slope having high water contents, humus was accumulated due to slow organic matter decomposition. The pH values also decreased due to organic acids from humus. However, we observed that organic matter and P concentration in soil increased.