It is very important to protect life, property at sea from any fire. Recommendation on improved fire test procedures for surface flammability of bulkhead ceiling and deck finish materials specifies a procedure for measuring fire characterizing their flammability and thus their suitability for use in marine construction. In this paper we investigated the positive expected by fire test procedures for flammability of bulkhead ceiling and deck finish materials. Also, unusual materials were analyzed. Finally, we suggest methods to solve several problems related to unusual materials.
Proceedings of the Korea Institute of Fire Science and Engineering Conference
/
1997.11a
/
pp.404-412
/
1997
The pipes and cables buried below ground, which may have helped to improve city landscape, is becoming direct and indirect causes for various kinds of disaster in Korea. Every advantage from the use of utility tunnel can not be converted in a dollar since there is associated huge contribution to safe urban environment. The Korean government has a certain role to play in helping promote utility tunnels for the past years. Most recently, many utility tunnels have been being checked to find out safety level, especially fire safety level, and main problems and shortcomings are checked out as a result of this survey. Because the fire safety level of existing tunnel is low, possible approaches and solutions are presented according to the analysis of fire safety level. In order for these approaches to be effective, existing tunnel should be supplemented appropriately and extra equipment must be installed according to the solutions. Hopefully, by performing both improvement of existing utility tunnel that provide a fire/disaster proof and introducing new types of tunnel which influence utility management and maintenance, the recent disaster rate in Korea can be diminished up to a desirable rate in a near future.
Journal of Korea Society of Digital Industry and Information Management
/
v.14
no.4
/
pp.57-68
/
2018
This paper presents a smart firefighting appliances monitoring system based on big data analytics platform using GS1 for Smart City. Typical firefighting appliances are fire hydrant, fire extinguisher, fire alarm, sprinkler, fire engine, etc. for the fire of classes A/B/C/D/E. Among them, the dry chemical fire extinguisher have been widely supplied and 6 millions ones were replaced for the aging ones over 10 years in the past year. However, only 5% of them have been collected for recycling of chemical materials included the heavy metals of environment pollution. Therefore, we considered the trace of firefighting appliances from production to disposal for the public open service. In the paper, we suggest 1) a smart firefighting appliances system using GS1, 2) a big data analytics platform and 3) a public open service and visualization with the analyzed information, for fire extinguishers from production to disposal. It can give the information and the visualized diagrams with the analyzed data through the public open service and the free Apps.
A new methodology to detect forest fire burnt scars at near real time using MODIS (Moderate-resolution Imaging Spectroradiometer) data is presented here with a goal of introducing a new and improved capability to detect forest fire burnt scars in Thailand. This new technology is expected to increase the efficiency and effectiveness of the forest fire tackling resources distribution and management of the country. Using MODIS data in burnt scars detection has two major advantages - high availability of data and high resolution per performance ratio. Results prove the near real time algorithm suitable and working well in order to monitor the forest fire dynamic movement. The algorithm is based on the threshold separated linear equation of burnt and un-burnt. A ground truth experiment confirms the burnt and un-burnt? areas characteristics (temperature and NDVI). A threshold line on a scatter plot of Band I and Band 2 is determined to separate the burnt from un-burnt pixels. The different threshold values of NDVI and temperature use to identify pixels' anomaly, abnormal low NDVI and high temperature. The overlay (superimpose) method is used to verify burnt pixels. Since forest fire is a dynamic phenomenon, MODIS burnt scars information is suiting well to fill in the missing temporal information of LANDSAT for the forest fire control managing strategy in Thailand. This study was conducted in the Huai-Kha-Kaeng (HKK) Wildlife Sanctuary, Thailand
Kim, Dong-Hyun;Lee, Myung-Bo;Yoo, Se-Kuel;Na, Young-Eun;Choi, Won-Il;Kim, Eung-Sik;Jung, Ki-Chang
Fire Science and Engineering
/
v.22
no.5
/
pp.48-54
/
2008
Forest fires occur the world over, with large-scale fires constantly breaking out. A suppressant a type of forest fire chemical is widely used to respond to fires rapidly and effectively. In general, suppressants used for fires have been divided into dry powder, liquid, foam, and gel type, according to physical form and use. This study has conducted toxicity tests relating to phytotoxicity(Pinus densiflora seed germination rate and mortality of containerized seedling), and soil organism toxicity(earthworm acute toxicity tests), of these suppressants, with the loaded stream suppressant for direct forest fire extinguishing a Loaded Stream and foam concentrates generally being used in Korea. From the results of the tests, the loaded stream and the foam concentrate had an effect on the toxicity levels. In the case of the loaded stream type, it was observed that toxicity indicating a 100% lethality rate was found among all toxicity test methods. Therefore, it is determined that forest ecology environmental toxicity impact assessments related to the suppressant used to extinguish forest fires are necessary in the near future.
Lee Byung-Doo;Chang Kwang-Min;Chung Joo-Sang;Lee Myung-Bo;Lee Si-Young;Kim Hyung-Ho
Korean Journal of Environment and Ecology
/
v.20
no.2
/
pp.267-273
/
2006
The biomass of Pinus densiflora stands burnt out by the 2005 Yangyang forest fire was estimated based on the grades of fire severity; light, moderate and heavy. In order to measure the post-fire ground biomass in kg/ha, the ground fuels including shrub layer were collected and weighted and the crown biomass was estimated using allometric regressions and leaf area index for dry weight of P. densiflora. The pre-fire biomass was assumed to be equal to that of non-damaged P. densiflora stands having the same characteristics. The results indicated that the forest fire burnt out fuels of stands; 3,693 kg/ha in the light-damaged, 8,724 kg/ha in the moderately-damaged, and 17,451 kg/ha in the heavily-damaged forest stands.
The Journal of the Convergence on Culture Technology
/
v.7
no.1
/
pp.424-431
/
2021
This study explores fire prevention measures for single-person households on the phenomenon of an increase in single-person households due to changes in the family structure due to low birthrate and aging population, full marriage, non-marriage, separation, bereavement, and returning to farming villages, and increased flexibility in the labor market. The factor that affects the fire of single-person households is the residential environment problem at the structural level. In terms of behavior, there is an increase in fire occurrence due to the rearing of companion animals. In order to prevent fires in single-person households, safety regulations without exceptions are needed to improve the residential environment at the structural level. At the behavioral level, it is necessary to expand the prevention and safety guidance of related organizations. In addition, as a measure to prevent fire caused by companion animals, manufacturers of electric ranges should develop safety devices to prevent fires caused by companion animals, such as an automatic power-off device or power supply using a timer. It can also be an important means to create and distribute promotional videos of measures necessary to safely raise companion animals, or to develop and distribute disaster preparedness programs implemented in virtual reality.
This study was performed to propose measures to improve and secure safety in the scene activities of firefighters. First, the majority of firefighters thought that working environment and equipment in fire station were inadequate for perforeming work tasks safely. Second, influential factors threatening safe scene activities mainly arose externally such as insecure working conditions of firefighting or emergency scene. Third, improvement in working environments was pointed out as the most urgent issue to secure safety. Firefighters recognized the expansion of field workforce in system, personnel management and the foundation of hospitals for firefighters hospital in working environment, and the development and distribution of safe equipment and change and inspection of air respirator facepiece on regular basis in equipment as urgent issues to be improved.
This study aims to provide fundamental information required to establish an efficient maintenance and management system for fire fighting clothing which takes into account the domestic fire protection environment and situation. There aren't any detailed regulations and appropriate pre-inspection systems which would be required for proper maintenance of fire fighting clothing, as well as any test methods to determine the life spans of fire fighting clothing properly. Thus, this study tries to analyze the problems in use of fire fighting clothing and its maintenance situation and summarize overseas maintenance situation for fire fighting clothing. As a result, it is found that domestic fire fighting clothing is washed, repaired, and stored without any systematic management regulations. It is also found that the life spans of fire fighting clothing are determined, based on part of overseas management regulations on fire fighting clothing. Therefore, it is imperative to set up efficient management regulations and test methods for fire fighting clothing which would be required for efficient use of the fire fighting budgets and the life safety of fire fighters.
The purpose of this study to find the factors influencing the fire alarms using IoT firefighting facility management system data of Seoul Fire & Disaster Headquarters, and to present academic implications for establishing an effective prevention system of fire situation. As the number of high and complex buildings increases and former bulidings are advanced, the fire detection facilities that can quickly respond to emergency situations are also increasing. However, if the accuracy of the fire situation is incorrectly detected and the accuracy is lowered, the inconvenience of the residents increases and the reliability decreases. Therefore, it is necessary to improve accuracy of the system through efficient inspection and the internal environment investigation of buildings. The purpose of this study is to find out that false detection may occur due to building characteristics such as usage or time, and to aim of emphasizing the need for efficient system inspection and controlling the internal environment. As a result, it is found that the size(total area) of the building had the greatest effect on the fire alarms, and the fire alarms increased as private buildings, R-type receivers, and a large number of failure or shutoff days. In addition, factors that influencing fire alarms were different depending on the main usage of the building. In terms of time, it was found to follow people's daily patterns during weekdays(9 am to 6 pm), and each peaked around 10 am and 2 pm. This study was claimed that it is necessary to investigate the building environment that caused the fire alarms, along with the system internal inspection. Also, it propose additional recording of building environment data in real-time for follow-up research and system enhancement.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.