• Title/Summary/Keyword: fire effects

Search Result 860, Processing Time 0.026 seconds

Igniter and Thickness Effects on Upward Flame Spread

  • J.Q. Quintiere;Lee, C.H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.154-161
    • /
    • 1997
  • Several studies have developed upward flame spread models which use somewhat different features. However, the models have not considered the transient effects of the igniter and the burning rate. Thus, the objective of this study is to examine a generalized upward flame spread model which includes these effects. We shall compare the results with results from simpler models used in the past in order to examine the importance of the simplifying assumptions. We compare these results using PMMA, and we also include experimental results for comparison. The results of the comparison indicate that flame velocity depends on the thermal properties of a material, the specific model for flame length and transient burning rate, as well as other variables including the heat flux by igniter and flame itself. The results from the generalized upward flame spread model can provide a prediction of flame velocity, flame and pyrolysis height, burnout time and position, and rate of energy output as a function of time.

  • PDF

The Effects of Spray Characteristics of Water Mist on the Fire Suppression of Liquid Pool Fire (미분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향)

  • Oh, Sang-Youp;Kim, Ho-Young;Chung, Jin-Taek
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.215-221
    • /
    • 2003
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is $115{\sim}180{\mu}m$ with nozzle A and $130{\sim}190{\mu}m$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of O2 concentration.

  • PDF

A Study on Fire Characteristics in a Tall and Narrow Atrium

  • Sugawa, Osami;Takahashi, Wataru;Ohtake, Masanori;Satoh, Hiroomi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.353-360
    • /
    • 1997
  • The modeling on fire safety assessment for a tall and narrow atrium is carried out using a reduced and full scale atrium models based on the performances of flow behavior in and near comer fire and smoke ventilation system. The comer (or wall) effects on the flame behavior considering air entrainment into a flame was evaluated theoretically and experimentally. Temperature, upward velocity, inlet air velocity, and pressure difference between the atrium space and atmosphere were measured systematically in a reduced scale model. The performance of the modeling to estimate temperature rise and natural air ventilation volume was verified based on the experimental results. Smoke filling rate from a model fire source set at the center of a tall and narrow atrium is fastest in the other cases in which fire source set in or near a corner. This suggested that the centering of the fire source is acceptable as the fire source position to assess the fire safety design for a tall and narrow atrium.

  • PDF

Fire Acupuncture for Varicose Veins in the Lower Extremities: A Review of Randomized Controlled Trials

  • Onyou Jo;Jiyoon Lee;Sangmin Park;Jaewook Shin;Saerom Choi;Seongyong Choi
    • Journal of Acupuncture Research
    • /
    • v.40 no.3
    • /
    • pp.177-187
    • /
    • 2023
  • Varicose veins have a substantial burden on individuals' aesthetics and overall quality of life. The current body of research on Korean medical interventions for varicose veins is limited in Korea, and exploration into clinical trends is lacking. This review specifically analyzed fire acupuncture, which is an understudied intervention in Korea that demonstrated efficacy in alleviating pain and paralysis while promoting tissue regeneration. A comprehensive investigation of the China National Knowledge Infrastructure database was conducted, utilizing terms such as "varicose vein," "fire needle," "fire acupuncture," "burning acupuncture," "burning needle," "huǒzhēn," "xiàzhī jìngmài," and "jìngmài qūzhāng." This review included 14 studies investigating the role of fire acupuncture in treating varicose veins. We extracted variables, including age, sex, disease duration, intervention method, treatment frequency, treatment period, acupoints, and outcomes. Fire acupuncture appeared as the primary intervention method, followed by general acupuncture. The protruding part of varicose veins is the main treatment area for fire acupuncture, while the acupoints BL57 and ST36 were most frequently utilized for general acupuncture. Treatment results revealed significant improvement in all studies. However, there are limitations, such as scarce studies, limited side effects studies, and potential bias. Consequently, extensive and well-structured future studies are necessary to demonstrate the role of fire acupuncture in varicose veins.

An Experimental Investigation on Combustion Characteristics of the Knockdown Building (조립식 건축물의 화재특성연구)

  • Lee, Jung-Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.30-35
    • /
    • 2008
  • The recent fire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Combustion products including $O_2$, $CO_2$, CO, $NO_x,$, $SO_x$, HCI, HCN were measured, in order to investigate the hazard-reduction effects of employing gas mask protected with filter during the fire emergency of residential container buildings. According to the test results, whether or not employing the filter showed a sheer difference in the toxicity of the fire-induced gases, and then the importance of wearing a gas mask was evidently demonstrated.

Properties of Fire Resistance of Concrete with Contents of Polypropylene Fiber and Specimens Size (폴리프로필렌 섬유의 혼입률 및 부재크기 변화에 따른 콘크리트의 내화 특성)

  • 전선천;황인성;이병열;양성환;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.463-468
    • /
    • 2001
  • A lot of considerations on the spatting by fire of high performance concrete should be taken into for fire resistance of the concrete structures. In this paper, fire resistance of high performance concrete is described using polypropylene fiber, which is known to be contributed to fire resistance. Strength level and member size are varied with. According to test results, spatting by fire takes place more easily, as W/C increases and member size decreases. It shows that concrete containing polypropylene fiber has good effects on preventing spatting by fire. In case high performance concrete does not contain polypropylene fiber, residual strength shows to be decreased remarkably compared :o that of normal concrete. Whereas, in case 0.1% of polypropylene fiber contents, high performance concrete shows higher residual strength than that of normal concrete. As member size is smaller, residual strength shows to be decreased.

  • PDF

Numerical Analysis of Heat Flow in Fire Compartment using SIMPLE Algorithm (SIMPLE Algorithm을 이용한 화재실의 열 유체의 수치해석)

  • 김광선;손봉세
    • Fire Science and Engineering
    • /
    • v.6 no.1
    • /
    • pp.17-22
    • /
    • 1992
  • We have derived the general transfer equation for governing the continuity, energy transfer, mass and momentum transfer, and turbulent energy dissipation rate within the fire compartment which has the 800t fire source at the center of the floor. The governing transfer equations have been descretized using the finite volume approach and numerically experimented under the SIMPLE algorithm. In order for the SIMPLE algorithm approach to be physically reliable, the test results are compared with those of Morita's SOR Method using Conjugate Residual Method and found to be close to physical values though the computational convergence time still remains to be upgraded. The treatment of source terms in the system of finite difference equations has been critical in order to converge the governing equations within the appropriate time steps. The criteria of convergence allowance for the whole domain have been checked and the sudden change of the non-linear effects from the source term have been avoided. The criteria has been allowed to be for 5$\times$10$^{-5}$ .

  • PDF

Fire Mitigation by Partitioning a Sodium Loop Building (화재완화를 위한 소듐 루프 건물의 구획화)

  • 김병호;권상운;정경채;김광락;황성태
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.32-44
    • /
    • 1998
  • Analysis on the study for the sodium fire mitigation was carried out using the CONTAIN-LMR code. Sodium loop building was partitioned into the many cells, in which the safety venting systems were installed for the purpose of improving the sodium fire safety and minimizing its effect on the sodium loop building. The effects of sodium fire on sodium loop building partitioned into the many cells and not partitioned were investigated. The peak pressure and temperature of each cell accompanied by sodium fire in sodium loop building partitioned were lower than those of sodium loop building not partitioned. In the case of partitioning sodium loop building, the pressures, temperatures and aerosols into cells were transferred through propagation path of CONTAIN-LMR sodium fire model simulated by this study, and the effect of sodium spray fire on sodium loop building was mitigated by partitioning building. In addition, the excessive rise of pressure into cells was prevented by installing the over-pressure exhaust valve and under-pressure exhaust valve on the flow path between cells.

  • PDF

The Improvements for Fire Retardancy and Radiation Resistance of Chloroprene Rubber (클로로프렌 고무의 난연성 및 내방사선 특성 향상)

  • Kim, Ki-Yup;Lee, Chung;Ryu, Boo-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1205-1211
    • /
    • 2004
  • This study has investigated radiation degradation of chloroprene rubber in the presence of some fire retardant. Ammonium polyphosphate, aluminium trihydroxide, magnesium hydroxide, calcium carbonate and antimony trioxide were selected as flame retardant. Samples were irradiated using a Co$^{60}$ ${\gamma}$ -ray and ray up to 2000 kGy at a dose rate of 5 kGy/hr in the presence of air atmosphere at room temperature. After irradiation, samples were assessed fire retardancy with electrical properties and mechanical properties. Some considerations concerning the effects of the fire retardants added to chloroprene rubber on the radiation and thermal stability of chloroprene rubber are presented. From fire retardancy with electrical and mechanical property measurements, it was found that addition of magnesium hydroxide resulted in maximum fire retardant effect.