• Title/Summary/Keyword: fire effects

Search Result 860, Processing Time 0.031 seconds

A Study on Rescue of the Human Life against the Fire in the High-rise Building (고층건물 화재시 인명구조 방법에 관한 연구)

  • Choi, Kwon-Joong
    • Korean Security Journal
    • /
    • no.5
    • /
    • pp.309-325
    • /
    • 2002
  • It was because mankind could use the fire that we have been civilized. creating a brilliant culture and developing an industrial society. While fire is very useful to our life, the number of the victims of fire continues to increase, This study suggests the ways to rescue the people safely when they are subject to a fire in a high-rise building. To this end, the concept of fire is reviewed. Fire breaks out when the conditions for congestion are met, and therefore. if any of the conditions can be blocked, the fire will be extinguished. In other words. the knowledge of such conditions will greatly help the fire fighters to rescue the people, and so. such conditions for congestion as flammable, heat, oxygen and chain reaction are examined. In addition, the effects of such by-products of fire as heat and smoke on human body are reviewed. In order to rescue the people more safely, the fire fighters are requested to review the situation and design a rescue strategy before being engaged in a full-scale rescue activity. This study discusses various rescue methods using such passages or equipments as stair case, double ladder, special fire fighting vehicle, elevator, jumar, rope, helicopter, etc. In conclusion. since it is more difficult to rescue the people from a high-rise building than from the ground, it is essential to design a rescue program not after fire but before it and thereby, minimize the number of victims.

  • PDF

A real scale test on performance of water spray systems in tunnel fire (터널화재시 물분무소화설비의 성능에 대한 실대시험)

  • Park, Kyung-Hwan;So, Soo-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.4
    • /
    • pp.341-347
    • /
    • 2010
  • The performance of water spray system installed to reduce risks of tunnel fire is investigated by a real tunnel fire test. In case of A class fire, Pool fire, and car fire, the nozzle of water spray has had a marvelous effect to reduce the temperature of hot smoke. And it is verified to have remarkable cooling effects when there is the air flow in a tunnel. Though this results, water spray system will be able to prevent a fire jump to decrease the air temperature in a tunnel and to protect tunnel facilities by the fire control.

A study on the reaction mechanism on the harmful gases related to the human physiology caused by fire and panic phenomenon(II) (화재발생시의 유해가스의 반응 메카니즘과 패닉현상(II))

  • Yoon, Moung-Hoon;Lee, Jae-Won;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.502-506
    • /
    • 2008
  • Smoke composed of harmful gases such as carbon monocide and carbon dioxide is reconized as the major killer in fire situation. Especailly it is said that smoke movement is related to the panic phenomenon which threatens the life seriously. The purpose of this study is to investgate and analyse the reaction mechanism of harmful gas caused by fire effects on the human psychology and panic phenomenon.

  • PDF

Numerical Investigation of Residual Strength of Steel Stiffened Panel Exposed to Hydrocarbon Fire

  • Kim, Jeong Hwan;Baeg, Dae Yu;Seo, Jung Kwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.203-215
    • /
    • 2021
  • Current industrial practices and approaches are simplified and do not describe the actual behavior of plated elements of offshore topside structures for safety design due to fires. Therefore, it is better to make up for the defective methods with integrated fire safety design methods based on fire resistance characteristics such as residual strength capacity. This study numerically investigates the residual strength of steel stiffened panels exposed to hydrocarbon jet fire. A series of nonlinear finite element analyses (FEAs) were carried out with varying probabilistic selected exposures in terms of the jet fire location, side, area, and duration. These were used to assess the effects of exposed fire on the residual strength of a steel stiffened panel on a ship-shaped offshore structure. A probabilistic approach with a feasible fire location was used to determine credible fire scenarios in association with thermal structural responses. Heat transfer analysis was performed to obtain the steel temperature, and then the residual strength was obtained for the credible fire scenarios under compressive axial loading using nonlinear FEA code. The results were used to derive closed-form expressions to predict the residual strength of steel stiffened panels with various exposure to jet fire characteristics. The results could be used to assess the sustainability of structures at risk of exposure to fire accidents in offshore installations.

Analysis for Forest Fire Damage Severity Map in Cheongyang

  • Jung Tae-Woong;Yoon Bo-Yeol;Yoo Jae-Wook;Kim Choen
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.537-540
    • /
    • 2004
  • Space-borne multi-sensor data could provide fire scar and bum severity mapping. This paper will present detail mapping of burnt areas in Cheongyange Yesan of Korea with ETM+ image. Burn severity map based on ETM+ image was found to be affected by strong topographic illumination effects in mountainous forest area. Topographic effect is a factor which causes errors in classification of high spatial resolution image like IKONOS image. Minnaert constants J( in each band of ETM+ image is derived for reduction of mountainous terrain effects. Finally, this paper computes quantitative analysis of forest fire damage by each forest types.

  • PDF

Parameter Effects on the Time to Reach Flashover Conditions in Single Room Fires (건물화재의 플래시오버 도달 시간에 영향을 미치는 인자들에 관한 연구)

  • Kim, Hyeong-Jin;Lilley, David-G.;Baek, Byung-Joon;Pak, Bock-Choon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1384-1388
    • /
    • 2003
  • In structural fires, flashover is characterized by the rapid transition in fire behavior from localized burning of fuel to the involvement of all combustibles in the enclosure. An investigation of parameter effects on the time to reach flashover conditions in a typical single room fire is undertaken using a zone method (FAST) and Thomas method. Major parameters affecting the time to reach flashover are found to be fire growth rate, ventilation opening area and internal room surface. The results of the FAST and the Thomas Method give very similar results of the time to reach flashover..

  • PDF

A Study on Properties of Hardboard from Japanese Larch Killed by Fire (일본잎갈나무 산화(山火) 고사목(枯死木)을 원료(原料)로 한 하드보드 재질연구(材質硏究))

  • Jun, Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.31-35
    • /
    • 1981
  • This study was carried out to investigate the properties of hardboard made from fire killed larch tree and also effects of standing period after killed by fire. The results are as follows; 1. There were no effects on hardboard properties among the standing period differences after killed by fire within about 2 years. 2. Specific gravities, moisture contents, water absorptions of the boards from dead trees have no differences compared with those of sound wood. 3. Bending strengths of the boards from dead trees we re decreased in the range of 24-28% of the boards from sound wood.

  • PDF

Numerical Study on the Effect of Damper Position on Characteristics of Thermal Flow at the Vestibules and Fire Door (댐퍼의 위치가 부속실 및 방화문에서의 열 유동 특성에 미치는 영향에 관한 수치해석 연구)

  • Moon, Hyo-Jun;Ko, Gwon-Hyun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The pressurized smoke control system is important for fire safety in building because it is directly concerned with egress time of people. Even though the damper plays an essential role in the pressurized smoke control system, the phenomena of backflow smoke occurs for a certain the damper position. The research for a position of damper effects on distribution of air flow at the fire door is not performed. In this study, numerical simulation using FDS 5.5 was carried out to analyze the effect of the position of damper on flow distribution at the fire door. To simulate real situation, effects of opening and closing of fire door was considered. As a result, when HRR was between 200 kW and 400 kW, in the case which the damper was on the opposite wall of the fire door, the back flow to the vestibules was large compared to the two other cases of damper position. But when HRR was above 400 kW, Effect on damper position was not occurred.

A Study on the Behaviour of Smoke Spread Caused by Vehicle Fire in a Road Tunnel (터널 내 차량 화재에 따른 연기 확산 거동에 관한 연구)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.365-372
    • /
    • 2012
  • This paper aims to evaluate the effects that presence, installation number and capacity of ventilation vent and presence of multiple fire sources have on the behaviour of smoke temperature induced by vehicle fire in road tunnel. Six types of scenarios were assumed and FDS was ran to simulate them. As the number of ventilation vents increases, the smoke temperature are calculated to be reduced, but it is shown that effects exerted by two ventilation vents are almost similar to ones by three ventilation vents. Capacity of ventilation vent has a greater impact on the reduction of smoke temperature than installation number of ventilation vents. Smoke temperatures computed for all scenarios except for scenario No. 1 (without ventilation vent) and scenario No. 6 (with multiple fire sources) above fire source are analyzed to be under $400^{\circ}C$ and it means that the radiation of smoke layer above fire source doesn't induce the ignition of materials around fire source.

The Effects of Transformational Leadership on Organizational Culture and Innovation in the Fire Fighting Organization (소방조직의 변혁적 리더십이 조직문화와 혁신에 미치는 영향)

  • Park, Chang-Soon;Choi, Kyu-Chool
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.104-114
    • /
    • 2013
  • This study is intended to figure out the effects of supervisors' transformational leadership on organizational culture and innovation in the fire fighting organization. To achieve this, a survey was carried out to fire officers from the National Emergency Management Agency and Seoul Metropolitan Fire & Disaster Headquarters. The results are as follows. First, the effect of supervisors' transformational leadership on organizational culture showed that supervisors' transformational leadership had an effect on group culture, norm culture and rational culture by sub-factors of organizational culture in the fire fighting organization. Second, the effect of organizational culture on organizational innovation showed that group culture and rational culture had an effect on organizational innovation. Third, the effect of supervisors' transformational leadership on organizational innovation showed that supervisors' transformational leadership had an effect on organizational innovation. As for findings stated above, supervisors' transformational leadership had positive effects on organizational culture and innovation in the fire fighting organization. Consequently, supervisors' energetic and change-seeking leader-ship for junior staffs with existing organization-and new generation-oriented new thinking system can contribute to rational culture and development-oriented innovation based on norms in the group.