• Title/Summary/Keyword: fire effects

Search Result 860, Processing Time 0.025 seconds

An Experimental Study on the Cooling Characteristics of an Infrared Detector Cryochamber (적외선 센서용 극저온 용기의 냉각특성에 관한 실험적 연구)

  • Kang Byung Ha;Lee Jung Hoon;Kim Ho-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.889-894
    • /
    • 2004
  • Infrared (IR) detectors are widely used for many applications, such as temperature measurement, intruder and fire detection, robotics and industrial equipment, thermoelstic stress analysis, medical diagnostics, and chemical analysis. Quantum detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal analysis of cryochamber includes the conduction heat transfer through a cold well, the gases conduction and gas outgassing, as well as radiation heat transfer, The transient cooling characteristics of an infrared detector cryochamber are investigated experimentally in the present study. The transient cooling load increases as the gas pressure is increased. Gas pressure becomes significant as the cooling process proceeds. Cool down time is also increased as the gas pressure is increased. It is also found that natural convection effects on cool down time become significant when the gas pressure is increased.

A Case Report of a Patient Who Has Dysgraphia and Articulation After a Stroke Treated by Sohamhyung-Tang (구음장애, 필기장애를 중심으로 한 중풍후유증에 소함흉탕(少陷胸湯)을 투여하여 호전된 1례 보고)

  • Kim, Changsig;Yun, Hyo-Joong;Lee, Soong-In
    • 대한상한금궤의학회지
    • /
    • v.10 no.1
    • /
    • pp.115-124
    • /
    • 2018
  • Objective : The purpose of this paper is to report the improvements of a patient who has suffered from aftereffects following stroke such as dysgraphia and articulation disorder, which is treated by herbal medication based on Shanghanlun disease pattern identification diagnostic system. Methods : According to 'Disease Pattern Identification Diagnostic System based on Shanghanlun Provisions', the patient was diagnosed as Taeyang-byung Gyeolhyung and number 138 provision, and was administered Sohamhyung-tang for 90 days. We recorded the progress of improvements based on the patient's statement and documented the patient's writing Results : The patient can write the letters such as U, 2, ㄹ,ㅇ more clearly and become confident on both writing and speaking. Conclusions : This case shows the effects of Sohamhyung-tang on aftereffects following stroke such as dysgraphia and articulation disorder. It was induced according to the 'Disease Pattern Identification Diagnostic System based on Shanghanlun Provisions' so that it suggest a potential interpretation, which is different with it of the text books Herbal Formula Science and Sanghallonjeonghae, on the provision no. 138. Also the usage of Sohamhyung-tang in this case may support the way far from the diagnosis of oriental neurological medicine, which explain the pathology of stroke as fire-heat(火熱), dampness-phlegm(濕痰), static blood(瘀血) and dual deficiency of qi and blood(氣血兩虛).

  • PDF

A Systematic Review of Acupuncture for Oculomotor Nerve Palsy

  • Ku, Yong Ho;Kang, Jae Hui;Kong, Hae Jin;Ryu, Hwa Yeon;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.36 no.2
    • /
    • pp.59-71
    • /
    • 2019
  • Acupuncture treatment for oculomotor nerve palsy has been increasing recently. This study analyzed randomized controlled trials (RCTs) and case reports, using the Cochrane risk of bias tool to investigate the efficacy of acupuncture therapy for oculomotor nerve palsy. This analysis was performed on March 7, 2019, using online databases (PubMed, Cochrane, NDSL, OASIS, CNKI) where 208 articles were retrieved. Of these, there were 18 case reports and 18 RCTs that matched the inclusion criteria, of which 32 studies used acupuncture as the primary intervention, 1 used pharmacopuncture, 1 used fire-needling, and 1 used electroacupuncture. The most commonly used acupoints were BL1, BL2, ST2, TE23, Ex-HN5, LI4, GB14, ST36, GB20 and GB1. Significant findings were reported in all RCTs. Six adverse events were reported in 3 RCTs, with no effect on the outcome. No side effects were reported in the case reports. The risk-of-bias analysis showed that the articles did not report the experimental protocol used and it was not clear whether the study was blinded. Hence, it was difficult to assess the risk of bias. Analysis of 36 studies showed that acupuncture therapy for oculomotor nerve palsy was effective in many cases. It was difficult to evaluate the potential bias.

Investigation on Ultimate Strength of STS304L Stainless Steel Welded Connection with Base Metal Fracture Using Finite Element Analysis

  • Lee, HooChang;Kim, TaeSoo;Hwang, BoKyung;Cho, TaeJun
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1139-1152
    • /
    • 2018
  • Many studies on the application of stainless steels as structural materials in buildings and infra-structures have been performed thanks to superior characteristics of corrosion resistance, fire resistance and aesthetic appeal. Experimental investigation to estimate the ultimate strength and fracture mode of the fillet-welded connections of cold-formed austenitic stainless steel (STS304L) with better intergranular corrosion resistance than that of austenitic stainless steel, STS304 commonly used has carried out by authors. Specimens were fabricated to fail by base metal fracture not weld metal fracture with main variables of weld lengths according to loading direction. All specimens showed a block shear fracture mode. In this paper, finite element analysis model was developed to predict the ultimate behaviors of welded connection and its validity was verified through the comparison with test results. Since the block shear behavior of welded connection due to stress triaxiality and shear-lag effects is different from that of bolted connection, stress and strain distributions in the critical path of tensile and shear fracture section were investigated. Test and analysis strengths were compared with those by current design specifications such as AISC, EC3 and existing researcher's proposed equations. In addition, through parametric analysis with extended variables, the conditions of end distance and longitudinal weld length for block shear fracture and tensile fracture were suggested.

Effects of 119 Paramedics Wearing Personal Protective Equipment on Blood Pressure, Pulse, and Breathing (119구급대원의 개인보호장비 착용이 혈압·맥박·호흡에 미치는 영향)

  • Yi, Seung-Ku;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.3
    • /
    • pp.89-96
    • /
    • 2021
  • This study analyzed the physical changes in 119 paramedics transporting equipment at the emergency site and performing post-cardiopulmonary resuscitation through experiments. First, the average heart rate increased by about 25 times comparing CPR was performed without physical load and with personal protective equipment after moving equipment. In the third quartile, it increased to about 27 times. Second, when CPR was performed without physical load, and CPR was performed after moving the equipment with personal protective equipment, both the body temperature was raised and the rising body temperature was measured within normal body temperature. Third, the change in respiration rate increased by 7 times on average comparing CPR was performed without physical load and CPR was performed after moving the equipment while wearing personal protective equipment. In the third quartile, it increased to about 11 times. Finally, the change in blood pressure increased by 26.6 mmHg on average comparing CPR was performed without physical load and with wearing personal protective equipment after moving the equipment, and increased by 31.2 mmHg on average in the third quartile.

Numerical Simulation of Water Table Drawdown due to Groundwater Pumping in a Contaminated Aquifer System at a Shooting Test Site, Pocheon, Korea

  • Kihm, Jung-Hwi;Hwang, Gisub
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.247-257
    • /
    • 2021
  • The study area has been contaminated with explosive materials and heavy metals for several decades. For the design of the pump and treat remediation method, groundwater flow before and during groundwater pumping in a contaminated aquifer system was simulated, calibrated, and predicted using a generalized multidimensional hydrological numerical model. A three-dimensional geologic formation model representing the geology, hydrogeology, and topography of the aquifer system was established. A steady-state numerical simulation with model calibration was performed to obtain initial steady-state spatial distributions of groundwater flow and groundwater table in the aquifer system before groundwater pumping, and its results were illustrated and analyzed. A series of transient-state numerical simulations were then performed during groundwater pumping with the four different pumping rates at a potential location of the pumping well. Its results are illustrated and analyzed to provide primary reference data for the pump and treat remediation method. The results of both steady-state and transient-state numerical simulations show that the spatial distribution and properties of the geologic media and the topography have significant effects on the groundwater flow and thus depression zone.

A Study on the Evaluation of Safety Culture in Specialty Contractor (전문건설업 안전문화 평가에 관한 연구)

  • Shin, Sang-Yeon;Paik, Sinwon;Jung, Sung-Lyoung
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.18-25
    • /
    • 2021
  • Specialty contractor facilities, which involve a combination of welding and commissioning, face a high risk of serious accidents such as fire, explosion, and suffocation associated with welding work, nitrogen, and argon use. In such facilities, the organizational safety culture has considerable impact on the frequency of accidents. In this study, a safety culture evaluation was conducted on specialty contractors. NOSACQ-50, a standardized survey method on safety culture, was selected as an assessment tool to evaluate the safety culture in specialized construction companies that could not afford to invest heavily in safety. The self-administered questionnaire survey was conducted with 201 workers of four construction companies and the results were analyzed. It was found that in companies with low safety culture, the occurrence of irrationality was 66.0%, while in companies with high safety culture, the occurrence of irrationality was 42.6%. Thus, the difference in the occurrence of irrationality by safety culture was statistically significant. The difference in safety culture level according to the experience of occurrence of irrationality was also significant. It was also found that the higher the belief in safety management authorization, safety responsibilities of managers, worker safety priorities, and safety system effects, the lower the probability of irrationality.

Analysis of Safety by Expansion of Hydrogen Charging Station Facilities (수소충전소 설비 증설에 따른 안전성 해석)

  • Park, Woo-Il;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.83-90
    • /
    • 2020
  • This study conducted a risk assessment using the HyKoRAM program created by international joint research. Risk assessment was conducted based on accident scenarios and worst-case scenarios that could occur in the facility, reflecting design specifications of major facilities and components such as compressors, storage tanks, and hydrogen pipes in the hydrogen charging station, and environmental conditions around the demonstration complex. By identifying potential risks of hydrogen charging stations, we are going to derive the worst leakage, fire, explosion, and accident scenarios that can occur in hydrogen storage tanks, treatment facilities, storage facilities, and analyze the possibility of accidents and the effects of damage on human bodies and surrounding facilities to review safety.

Axial strengthening of RC columns by direct fastening of steel plates

  • Shan, Z.W.;Su, R.K.L.
    • Structural Engineering and Mechanics
    • /
    • v.77 no.6
    • /
    • pp.705-720
    • /
    • 2021
  • Reinforced concrete (RC) columns are the primary type of vertical support used in building structures that sustain vertical loads. However, their strength may be insufficient due to fire, earthquake or volatile environments. The load demand may be increased due to new functional usages of the structure. The deformability of concrete columns can be greatly reduced under high axial load conditions. In response, a novel steel encasement that distinguishes from the traditional steel jacketing that is assembled by welding or bolt is developed. This novel strengthening method features easy installation and quick strengthening because direct fastening is used to connect the four steel plates surrounding the column. This new connection method is usually used to quickly and stably connect two steel components by driving high strength fastener into the steel components. The connections together with the steel plates behave like transverse reinforcement, which can provide passive confinement to the concrete. The confined column along with the steel plates resist the axial load. By this way, the axial load capacity and deformability of the column can be enhanced. Eight columns are tested to examine the reliability and effectiveness of the proposed method. The effects of the vertical spacing between adjacent connections, thickness of the steel plate and number of fasteners in each connection are studied to identify the critical parameters which affect the load bearing performance and deformation behavior. Lastly, a theoretical model is proposed for predicting the axial load capacity of the strengthened RC columns.

Crossover Temperature and Ignition Delay Time of Diluted Hydrogen-Air Mixtures (희석된 수소-공기 혼합기의 크로스오버 온도와 점화지연시간)

  • Dong Youl, Lee;Eui Ju, Lee
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.18-24
    • /
    • 2022
  • Hydrogen is a clean fuel and is used in many applications in power systems such as fuel cells. It has unique properties such as wide flammability, high burning velocity, and difficulty to liquefy, which lead to critical safety issues. Fire and explosion are the most frequently occurring accidents and one of the major reasons is autoignition. In the ignition process, the chemistry of hydrogen combustion depends mainly on radical pools, and the temperature at which chain-branching and terminating rates are equal is called the crossover temperature. This study addresses the homogeneous autoignition of diluted hydrogen-air mixtures to investigate the effects of dilution on the crossover temperature to prevent explosions in the future. The new criterion for crossover temperature is introduced by only hydrogen radicals to adjust more simply. The detailed calculations indicate that the crossover temperatures are low at high dilutions of carbon dioxide and nitrogen because the concentrations of active radicals are reduced when an inert gas is added. This result is expected to contribute to hydrogen safety and realize a hydrogen society in the future.