• Title/Summary/Keyword: fire effects

Search Result 860, Processing Time 0.022 seconds

An experimental investigation on the errect of air entrainment (공기유입이 화재강도에 미치는 영향에 대한 실험적인 연구)

  • Kim, Jin-Guk
    • Fire Protection Technology
    • /
    • s.21
    • /
    • pp.5-12
    • /
    • 1996
  • An experimental investigation has been made with the objcetive of studying the effects of air entrainment of fire strength. A rich jet flame is considered as an fire, and fire, and the air entrainment is controlled by introducing the tone excitation which is generated by means of a loudspeaker-driven cavity. The excitation frequency is chosen for the resonant frequency identified as a pipe resonance due to acoustic excitation. As the excitation intensity increases, the amplitude of oscillating velocity for inducing air entrainment is increased, the flame height decreased and the structure of diffusion flame gradually transformed to that of premixed flame.

  • PDF

Influence on the Satisfaction of Fire Fighting Equipment by Distribution of Fire Fighting Equipment: Focusing on Mediating Effect of Reliability of Fire Fighting Equipment (소방공무원들이 인지하는 소방장비 보급으로 소방장비 만족도에 미치는 영향: 소방장비 신뢰성의 매개효과를 중심으로)

  • Lee, Sun-Beom;Kim, Yang-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.8
    • /
    • pp.677-684
    • /
    • 2017
  • This study verifies effects of the distribution of fire fighting equipment on the satisfaction of fire fight equipment among fire officers and the mediating effect of the reliability of fire fighting equipment on the relationship between the two variables in order to provide preliminary data on the development of fire fighting equipments. Fire officers from the seven fire stations located in Gyeonggi-do province were selected and surveyed to achieve the purposes of the study. Using AMOS 18.0, structural equation modeling were applied to analyze the data. Major findings are as follows. First, the propriety of the amount of distribution of fire fighting equipment and the timeliness of distribution have positive effects on the reliability of fire fighting equipment. Second, the reliability of fire fighting equipment has a positive effect on the satisfaction of fire fighting equipment. Third, the propriety of the amount of distribution of fire fighting equipment has a positive effect on the satisfaction of fire fighting equipment. It was found that the reliability of fire fighting equipment has a partial mediating effect on the relationship between the propriety of the amount of distribution of fire fighting equipment and the satisfaction of fire fighting equipment.

Delphi Study on the Reduction of Cross-contamination and Improvement of Management System on Firefighting Protection Suit (소방 방화복 교차오염 저감 및 관리체계 개선을 위한 델파이 연구)

  • Kim, Soo Jin;Ham, Seunghon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.182-194
    • /
    • 2022
  • Objectives: This study evaluates and recommends the priority of policy implementation to improve the fire protection clothing management system used by firefighters and the reduction of cross-contamination from contaminated clothing at the scene of a fire. Methods: It consisted of 7 experts and conducted three interviews and two modified Delphi surveys. Through the results of previous research and interviews with experts, a plan to reduce cross-contamination of fire suits and improve the management system was first derived. An improvement plan was presented in the four areas including resources, management, fire protection related work, and laws and regulations, and the priority of policy implementation was derived by analyzing the importance and practicality of the policy at the same time. Results: As a result of the analysis, the first priority was education on the health effects of pollutants at the disaster scene for firefighters, and the second priority was the addition of SOP for the primary decontamination of on-scene personal protective equipment in preparation for the health effects of the disaster scene, and education for fire suppression and rescue workers. The next step was to improve the management system of personal protective equipment such as fire suits and develop a training course for systematic operation. Conclusions: This findings could be used in the implementation of mid- to long-term firefighting policies for the systematic operation and establishment of a systematic management system for personal protective equipment such as fire protective suits.

Effects of Fire Curtain and Forced Smoke Ventilation on Smoke Spread to Auditorium in Stage Fire of Theater (공연장 무대 화재 시 방화막과 강제 배연구가 객석으로의 연기 확산에 미치는 영향)

  • Kim, Jae Han;Kim, Duncan;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.28-36
    • /
    • 2017
  • In this work, the effects of fire curtain and forced smoke ventilation on smoke spread to auditorium in the stage fire of theater were investigated using the Fire Dynamics Simulator (FDS). For the stage of 31 m (Width)${\times}$34 m (Depth)${\times}$32 m (Height) in dimension, the fast growth fire condition with 10 MW of heat release rate was applied. The forced smoke ventilation was set based on the National Fire Safety Code (NFSC) and previous research. The gap distances between the fire curtain and proscenium wall was established to be 0 m and 0.5 m. When the fire curtain was attached completely to the proscenium wall without any gap, no smoke spread from the stage to the auditorium occurred, independent of forced smoke ventilation. When the gap distance between the fire curtain and proscenium wall was 0.5 m, the smoke layer in the stage descended to the lower height from the bottom than the case without the fire curtain, which was because the smoke spread to auditorium was impeded by the fire curtain. Under the same fire curtain condition, the case with the forced smoke ventilation led to decreasing the mass flow rate of outflow through the gap between the fire curtain and proscenium wall, as compared to the case without the forced smoke ventilation. Based on this study, it was confirmed that the fire curtain and forced smoke ventilation were the effective tools to hold down the smoke spread to the auditorium in the stage fire of theater.

A Fire Simulation of Light Railway Transit (경량전철시스템의 화재 시뮬레이션)

  • Won Chan-Shik;Lee Ki-Choon;Hur Nahmkeon;Mok Jae-Kyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.170-175
    • /
    • 2001
  • Fire inside light railway transit(LRT) was simulated for various fire scenarios using CFD analysis in order to assess the safety of passengers. Considered in the present paper are the effects of locations of fire, a fire size, an operation of ventilation system and an opening time of door on evolution of temperature and smoke concentration inside the LRT. For fire simulation, fire cells releasing heat and smoke corresponding to fire size were positioned at the location of fire. From the results, it is seen that the ventilation system and the opening time of door were the most important factors on temperature and smoke concentration inside the LRT

  • PDF

Fire Behavior of Steel Columns Encased by Damaged Spray-applied Fire Resistive Material

  • Kwak, Yoon Keun;Pessiki, Stephen;Kwon, Kihyon
    • Architectural research
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • A Steel column with damaged spray-applied fire resistive material (SFRM) may exhibit reduced structural performance due to the effects of elevated temperature during fire events. Thus, the fire load behavior of steel columns with removed or reduced SFRM needs to be examined to predict the structural damage by fire. FEM analyses were performed for the flange thinning removal models in which the SFRM was reduced as a constant strip in thickness at the top flange of the column. The temperature results for all models obtained from the heat transfer analyses were included as an initial condition in the FEM structural analyses. In this study, the results of analysis show that even small remnants of SFRM led to an effective reduction of temperature at any given fire duration, and improved significantly the axial load capacity of a column as compared to the complete removal cases of SFRM.

Study on Changes of the Moisture Content of Sprayed Fire-Resistive Material according to Temperature Conditions (온도조건에 따른 내화뿜칠피복재의 함수율 변화 검토)

  • Lee, Gun-Cheol;Choi, Jung-Gu;Lee, Gun-Young;Kim, Dae-Hoi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.212-213
    • /
    • 2014
  • In case of fire spray protection sheath, fire resisting capacity is assessed for each material and installation method according to fire-resistive construction recognition. This study reviews effects of the percentage of water content that exist in fire spray protection sheath during the assess process of fire resisting capacity on fire resisting capacity, and changes of the percentage of water content according to temperature conditions. As a result of exams, as curing temperature is higher and thickness of specimen is thinner, decrease of the percentage of water content becomes significant.

  • PDF

Study on the Fire Behaviour of Composite Beam (H형강 합성보의 화재거동에 관한 실험적 연구)

  • Kim, Sung-Bae;Choi, Seung-Kwan;Han, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.84-90
    • /
    • 2008
  • This paper aims to experimentally investigate the in-fire performance of composite beams with respect to the effects of load ratio and shear interaction. Under a Standard ISO834 fire, the development of temperature and deflection of simply supported composite beams were recorded. In particular, the transition of temperature distribution across the cross-section. The fire resistance of composite beam was interpreted regarding the level of shear interaction.