• Title/Summary/Keyword: fire effects

Search Result 860, Processing Time 0.026 seconds

A Verification Study on the Demand Performance of Fabric Duct for Localization Development of Naval Vessel (해군 수상함 국산화개발 천 덕트의 요구성능 검증연구)

  • Jung, Young In;Choi, Sang Min;Jung, Hyun Sub;Sim, Min Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.468-474
    • /
    • 2020
  • Metal ducts for transporting air conditioning and heating inside ships have recently been replaced by cloth ducts that have the advantage of delivering air evenly to the compartments, with excellent noise reduction in major compartments, such as combat command rooms, steering rooms, and sound detector cabins. Since the performance requirements of fabric ducts for vessels are strict, and the entire length of the ducts was imported from Korea, the government wants to create economic effects through localization of fabric ducts. Air permeability and fire prevention performance tests verified the applicability to naval vessels of fabric ducts developed by Hyundai Heavy Industries and HiDact, and performance requirements presented in the POS were verified. As a result of the tests, the fabric ducts met the requirements for air permeability and fireproof performance.

A simple estimate of the carbon budget for burned and unburned Pinus densiflora forests at Samcheok-si, South Korea

  • Lim, Seok-Hwa;Joo, Seung Jin;Yang, Keum-Chul
    • Journal of Ecology and Environment
    • /
    • v.38 no.3
    • /
    • pp.281-291
    • /
    • 2015
  • To clarify the effects of forest fire on the carbon budget of a forest ecosystem, this study compared the seasonal variation of soil respiration, net primary production and net ecosystem production (NEP) over the year in unburned and burned Pinus densiflora forest areas. The annual net carbon storage (i.e., NPP) was $5.75t\;C\;ha^{-1}$ in the unburned site and $2.14t\;C\;ha^{-1}$ in the burned site in 2012. The temperature sensitivity of soil respiration (i.e., $Q_{10}$ value) was higher in the unburned site than in the burned site. The annual soil respiration rate was estimated by the exponential regression equation with the soil temperatures continuously measured at the soil depth of 10 cm. The estimated annual soil respiration and heterotrophic respiration (HR) rates were 8.66 and $4.50t\;C\;ha^{-1}yr^{-1}$ in the unburned site and 4.08 and $2.12t\;C\;ha^{-1}yr^{-1}$ in the burned site, respectively. The estimated annual NEP in the unburned and burned forest areas was found to be 1.25 and $0.02t\;C\;ha^{-1}yr^{-1}$, respectively. Our results indicate that the differences of carbon budget and cycling between both study sites are considerably correlated with the losses of living plant biomass, insufficient nutrients and low organic materials in the forest soil due to severe damages caused by the forest fire. The burned Pinus densiflora forest area requires at least 50 years to attain the natural conditions of the forest ecosystem prior to the forest fire.

A Study on Combustion Characteristics of Fire Retardant Treated Wood (난연처리된 목재의 연소특성에 관한 연구)

  • Park, Hyung-Ju;Kang, Young-Goo;Kim, Hong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.4 s.132
    • /
    • pp.38-44
    • /
    • 2005
  • This study was carried out to investigate the combustion characteristics of flame retardant treated wood by water-soluble flame retardants which are made from mixture of aqueous solution of monoammonium phosphate, sodium borate and zinc borate. The combustion characteristics for flame retardant treated wood were carried out using thermal analysis (TGA, combustion heat) and flame retardant test (LOI, flame propagation). The results of thermal analysis and flame retardant test are as follows; 1) The sample treated by F4 showed excellent flame retardant effects in almost all of combustion characteristics. 2) From TGA curves, all the samples undergo pyrolysis and oxidation in two main discrete steps. 3) The effect of flame retardant for softwood is higher than those for hardwood, and the combustion heat has decreased with increase of the content of flame retardant. 4) LOI values are almost similar in flame retardant treated wood samples. The range of LOI is from 24 to 30. However, these values are much higher than LOI value of non-treated wood sample. 5) The blended aqueous solution had a final in the range of about pH 8.4, and a slight odor of ammonia.

Combustion Characteristics of Ionized Fuels for Battery System Safety (배터리 시스템 안전을 위한 이온화 연료의 연소 특성)

  • Ko, Hyeok Ju;Lee, Eui Ju
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.22-27
    • /
    • 2018
  • Many electronic devices are powered by various rechargeable batteries such as lithium-ion recently, and occasionally the batteries undergo thermal runaway and cause fire, explosion, and other hazards. If a battery fire should occur in an electronic device of vehicle and aircraft cabin, it is important to quickly extinguish the fire and cool the batteries to minimize safety risks. Attempts to minimize these risks have been carried out by many researchers but the results have been still unsatisfied. Because most rechargeable batteries are operated on the ion state during charge and discharge of electricity and the combustion of ion state has big difference with normal combustion. Here we focused on the effect of ions including an electron during combustion process. The effects of an ionized fuel on the flame stability and the combustion products were experimentally investigated in the propane jet diffusion flames. The burner used in this experiment consisted of 7.5 mm diameter tube for fuel and the propane was ionized with th ionizer (SUNJE, SPN-11). The results show that toe overall flame stability and shape such as flame length has no significant difference even in the higher ion concentration. However the fuel ionization affects to the pollutant emissions such as NOx and soot. NOx and CO emissions measured in post flame region decreased by fuel ionization, especially high fuel velocity, i.e. high ion density. TGA analysis and morphology of soot by TEM indicates that the fuel ionization makes soot to be matured.

Effects of the Treated Chemicals on the Flexual and Physical Properties of Fire Retardant Treated Particleboards (내화처리(耐火處理) 파티클 보오드의 휨강도(强度)와 물리적(物理的) 성질(性質)에 미치는 약제(藥劑)의 영향(影響))

  • Lee, Phil-Woo;Kwon, Jin-Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.39-48
    • /
    • 1983
  • This research was performed to investigate the manufacturing possibility of the particleboard treated with commercial fire retardant chemicals. Laboratory test boards at this investigation were made from particles treated by soaking into 5, 10, 15, and 20 percent concentration solutions of ammonium sulfate and Minalith before resin was applied. According to the results, MOR (modulus of repture) and MOE (modulus of elasticity) in flexure exceeded type 100 (100 kgf/$cm^2$, $1.5{\times}10^4\;kgf/cm^2$) of the Korean Industrial Standard (KS F 3104). Except for 15 and 20 percent chemicals concentrations of Minalith, every internal bond stress values met type 100 (1.5 kgf/$cm^2$) of KS F 3104. However thickness swelling values of fire retardant treated particleboards were not reached in the Standard (12%).

  • PDF

The Ventilation Plane Due to Smoke Driving Combined Forces in Super High-Rise Buildings (초고층 건물에서 연기이동 복합력에 의한 환기계획)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.82-87
    • /
    • 2016
  • The ventilation system for the efficient operation of the building services systems in the ventilation plan of super high-rise buildings is used to combine smoke control systems. This study evaluated models of super high-rise buildings with four basement levels and 59 stories and investigated the pressure distribution of each floor by the smoke driving forces by numerical analysis. The smoke driving forces on the building of analytical model was analyzed to determine the effects of the ventilation plan and smoke control plane. In addition, when a combination with ventilation and smoke control of the kitchen ventilation damper in the ventilation plan of analysis model building was designed based on the these results, the relationship between the opening and closing force of the damper and smoke driving combined forces to act on the design pressure of the damper by a motion analysis simulation. The driving units of the damper were selected from the analytical results.

Long-Term Estimation of 119 Ambulance Services by Demographic Changes in Korea (인구 변동에 따른 119 구급 서비스의 장기 추계)

  • Kang, Kyunghee
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.105-111
    • /
    • 2018
  • Based on the Statistical Yearbook of 119 Emergency Medical Services in 2017 (National Fire Agency, 2018) and Population Projection by Province: 2015~2045 (Statistics Korea, 2017), this study analyzed the effects of population changes, such as low fertility and aging on the use of ambulance services in the future. The population of Korea is expected to decline after peaking in 2031, but the number of elderly people aged over 70 is expected to continue to increase. The rates of emergency ambulance transport (REAT, the number of patients transferred per 1,000 inhabitants) are not changed significantly, compared to the recent trends, but the ambulance services for elderly over 70 years of age will increase exponentially. Therefore, the population changes due to low fertility and aging is accompanied by a quantitative and qualitative change in ambulance services, and from the long term perspectives, it is necessary to consider not only the effective response of ambulance services due to aging, but also the adjustment of existing jurisdictions due to population changes and the relocation of manpower and resources.

Characteristics and Risk Assessment of Flame Spreading Over Metal Dust Layers (퇴적금속 분진층을 전파하는 화염의 연소특성과 위험성 평가)

  • Han, Ou-Sup
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.47-52
    • /
    • 2005
  • The wide use of metal dusts have been found in industrial field and many dust explosion accidents occur by fire spread of dust layer. In this study, we developed a new experimental device to examine fire and explosion characteristics of the dust layer. Aspects of the burning zone over metals(Mg, Zr, Ta, Ti, etc) and PMMA(Polymethyl methacrylate) dust layers have been investigated experimentally to clarify behaviors (Spread rate and quenching distance) and effects of $N_2$ surrounding gas on the fire spread over metal dust layers. From the experimental result, it was found that the spread rate of metal dusts is larger than PMMA, the dependability of spread rate over the thickness of dust layer is small, and the minimum oxygen concentration of spread flame over Mg dust layer is 3.6-3.7 vol%. Since high correlation between the spread rate and the reciprocal of quenching distance was seen, relative risk prediction in those inflammable parameters can be predicted.

Investigation of Hydrodynamic Force in a Portable Water Storage Tank of Reentrant Bottom Shape using Nonlinear Peregrine Model (바닥면이 오목한 이동형 소방용수 저장탱크의 수직 벽면에서의 동수력 연구: 비선형 Peregrine 모델)

  • Park, Jinsoo;So, Soohyun;Jang, Taek Soo
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.61-65
    • /
    • 2019
  • In the present study, the hydrodynamic force affected by a lapping wave induced by supplied falling water acting on the vertical wall of a portable water storage tank was analyzed using a nonlinear Peregrine model. The lapping wave's maximum run-up amplitudes and the hydrodynamic forces in the wall of the tank measured by linear and nonlinear Peregrine's models were compared numerically. As a result, it was concluded that the linear model may underestimate the effects on the vertical wall; therefore, it is more appropriate to use a nonlinear Peregrine model. Furthermore, this result can contribute to the stable structural designs of portable water storage tanks.

A Bibliographic investigation in the method of Chong-Yol-Sa-Hwa(淸熱瀉火) on the treatment of Cerebro Vascular Attack (C.V.A.) (중풍치료(中風治法)에 있어서 청열사화법(淸熱瀉火法)에 대(對)한 문헌적(文獻的) 고찰(考察))

  • Park, Jung-Yang;Byun, Il
    • The Journal of Internal Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.155-165
    • /
    • 1991
  • On the treatment of C.V.A, I obtain the results through the bibliographic investigation in the method of Chong-Yol-Sa-Hwa as follows ; 1. The method of Chong-Yol-Sa-Hwa on the treatment of CVA. is used for the occation of flaming fire in the heart caused by fire emotions in excess (五志過極), difficiency of Yin, flaming up of excessive in liver and plegm-heat. 2. The representative symptoms which can be used by the method of Chong-Yol-Sa-Hwa are firerishness, redness on face, foul breath, fidgets, angry, high fever, constipation slimy and greasy yellow coat of the tongue, and the pulse shaped on full-rapid (洪數), tautsmaooth and rapid (弦滑血數). 3. The general prescription on the method of Chong-Yol-Sa-Hwa are Bang pung tong sung-San, Yangkyuk-San, Backho-Tang, Sosiho-Tang, Samhwa-Tang, Chibo-Tan and Woohwang chongsim-Hwan on excessive symptom-complex, Yookmichihwang-Tang-Kakam, Samool-Tang-Kakam and Youngyangkak-Tang on insufficency symptom complex. 4. The most frequently dosed medicinal plants are Seok-ko, Chi-mo, Dae-Hwang, Mang-cho, Hwang-kewm, Hwang-back, Chi-ja, Si-ho, Han-Su-Seok, Yong-Tam-Cho, Mok-Tan-Pi and Saeng-Chi-Hwang. 5. The method of chong-Yol-Sa-Hwa might be expressed good medicinal effects adopted on the symptoms or flaming evil fire (火旺) after awakend and ‘Yang’ occlusion of Chung-Chang-Pu (中臟脈) which is accompanied with the method of purgation, break through the plegm, resuscitate and nourishing the Yin.

  • PDF