• Title/Summary/Keyword: fire effects

Search Result 860, Processing Time 0.023 seconds

A Study on the Efficient Management of Volunteer Fire Department (의용소방대의 효율적 운영에 대한 연구)

  • Lee, Wonjoo;Oh, Hyunchul;Lee, Kiyoung
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.148-157
    • /
    • 2016
  • The purpose of this study is to investigate the influence of organizational culture to the activities satisfaction of volunteer firefighter. For that, we surveyed 182 volunteer firefighters worked in Sejong city. The survey was analyzed the reliability in questionnaire design by SPSS 20.0 win program. The interrelationship of each factors were confirmed by analysis of frequency, percentage and regression analysis. The regression analysis was performed in order to investigate effects of group, development, hierachy, and rationality culture based organizational culture on activities satisfaction of volunteer firefighter. A factor of group and development culture in organizational culture was found to be a positive influence on the activities satisfaction of the volunteer firefighter under significance probability of < 0.05. The bigger group and development culture the volunteer fire department, the higher the activities satisfaction of the volunteer firefighter. This paper is expected to serve as a basis for the efficient operation of the volunteer fire department in Korea.

A Study on Fire-proof Characteristics of Ultra High Strength Concrete Using Polyamide Fiber (폴리아미드섬유를 사용한 초고강도 콘크리트의 내화성능에 관한 연구)

  • Lee, Soo-Choul;Jeon, Joong-Kyu;Jeon, Chan-Ki
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.4
    • /
    • pp.286-293
    • /
    • 2011
  • Accordingly architectural structure is getting high-rise and bigger, a use of high strength and high performance concrete has been increased. High performance concrete has cons of explosion in a fire. This explosion in the fire can cause the loss of the sheath on a concrete surface, therefore it effects that increasing a rate of heat transmission between the steel bar and inner concrete. Preventing this explosion of high performance concrete in the fire, many kinds of researches are now in progressing. Typically, researches with using polypropylene-fiber and steel-fiber can prove controling the explosion, but the reduction of mobility was posed as a problem of workability. Consequently, to solve the problem as mentioned above, concrete cans secure fire resisting capacity through the using of coating liquid, including Ester-lubricant and non-ionic characteristic surfactant. This research has been drawn a ideal condition in compressive strength areas of concrete by an experiment. When applying 13mm of polyamide fiber, proper fiber mixing volume by compressive strength areas of concrete more than 2.5kg in 160MPa. These amount of a compound can control the explosion.

Effects of fire on Vegetation and Soil nutrients in Mt. palgong (팔공산에서 식생과 토양에 미치는 산불의 영향)

  • Sim, Hak-Bo;Kim, Woen
    • The Korean Journal of Ecology
    • /
    • v.21 no.5_1
    • /
    • pp.465-473
    • /
    • 1998
  • This study was carried out to investigate the developmental process of plant community during the secondary succession and changes of soil properties in the burned areas lapsed 28 years after the forest fire in Mt.Palgong. The forest fire occurred on March, 1969 and the red pine (pinus densiflora) forest and its floor vegetation were burned down. The results are summarized as follows: the floristic composition of burned and unburned areas were composed of 49 and 48 species of vascular plants, respectively. The dominant species based on SDR4 of the burned sites were Lespedeza maximowicxii(87.75), Carex humilis (62.94), Rhododendron schippenbachii(55.78) and Miscanthus sinensis var.purpurascens (51.94). In contrast, Pinus densiflora (81.17), Quercus serrata (53.58)m Carex humilis (53.11) and Miscanthus sinenis var. purpuracens (52.42) were dominant in the unburned area. The biological spectra showed the $H-D_1-R_5-e$ type in both areas. The indices of similarity (CCs) between the two areas were 0.80. Degree of succession (DS) was 734 in the burned area and 809 in the unburned area. The species diversity (H) and evenness indices (e) in the burned and unburned areas were 2.05, 2.13 and 0.53, 0.55, respectively. Dominance index (C) in the burned and unburned areas were 0.30 and 0.32, respectively. Soil properties such as soil pH, content of organic matter, total nitrogen, total carbon, exchangeable potassium, sodium, calcium, and magnesium in burned area were comparatively higher than those of unburned area. Monthly changes of soil properties were of little significance except for some cases. These results suggest that there was relationship between trend of vegetation recovery and the changes of soil properties after the forest fire. Mixed forestation of fire-resistant species and nitrogen fixation species will be effective for reforestation after the forest fire.

  • PDF

A Study on the Precautions Effects of the Enclosure Integrity Test for the Gaseous Extinguishing Systems: Focusing on the Power Plant (가스계 소화설비의 밀폐도 시험에 영향을 미치는 사전조치에 관한 연구: 발전소를 중심으로)

  • Kim, Young-Chul;Jo, Il-Hyun;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • The present study was aimed to analyze enclosure integrity test, which is the performance experiment of soaking time, in a fire zone equipped with gaseous extinguishing system in an effort to find understand the effect of precaution factors upon the success of fire extinguishment. To achieve the goal of this study, it divided the fire zones of internal and external power plants into ones taking precaution measures and not taking them and then enclosure integrity test was given respectively. Therefore, this study examined the success rate if the test according to the presence and absence of the precaution measure and confirmed the failure factors, designed concentration soaking time and proportion of leakage area to total volume area by type of gaseous extinguishing system and rooms. Precaution measures were applied to the fire zones without them to confirm the increase of the success rate of enclosure integrity test. By doing so, it was found that reduced number of experiments caused by failure led to cost saving.

A Study on the Delay Effect of Smoke Diffusion by the Installation Intervals and the Blockage Ratio of the Fire Smoke Diffusion Delay Device in a Great Depth Underground Double-Deck Tunnel (대심도 복층터널 화재연기 확산지연장치 설치간격 및 차폐율에 따른 화재연기 지연효과 연구)

  • Yang, Yongwon;Han, Jaehee;Lee, Yuntaek;Moon, Jungjoo;Shin, Taegyun
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.596-603
    • /
    • 2018
  • The traffic congestion is frequently occurring due to increasing demand for vehicles and development of subcenter in roads of domestic-downtown. The design of a Great depth underground double-deck tunnel planned for construction as a solution however it's mainly for a compact-car. Its low height and small section cause causalities when fire occurs. From this study, the delay system for fire smoke diffusion is developed to minimize the occurrence of casualties when fire occurs in the Great depth underground double-deck tunnel and the CFD(Computational Fluid Dynamics) is used to find the optimal installation interval and the blockage ratio to maximize the system effects. The study analyzed the shorter the installation interval of the system, the higher the smoke delay effect but the efficiency-change tends to be slight above a certain distance and the larger the blockage ratio, the higher the effect but the efficiency-difference is slight according to installation interval.

Experimental and numerical investigation on post-earthquake fire behaviour of the circular concrete-filled steel tube columns

  • Wang, Yu-Hang;Tang, Qi;Su, Mei-Ni;Tan, Ji-Ke;Wang, Wei-Yong;Lan, Yong-Sen;Deng, Xiao-Wei;Bai, Yong-Tao;Luo, Wei;Li, Xiao-Hua;Bai, Jiu-Lin
    • Steel and Composite Structures
    • /
    • v.38 no.1
    • /
    • pp.17-31
    • /
    • 2021
  • Post-earthquake fire is a common disaster which causes serious safety issues to infrastructures. This study aims to investigate the residual loading capacities of circular concrete-filled steel tube (CFST) columns under post-earthquake fire experimentally and numerically. The experimental programme contains two loading steps - pre-damage cyclic loading at room temperature and transient state tests with constant compression loads. Three finite element models are developed and validated against the test results. Upon validation, a total of 48 numerical results were generated in the parametric study to investigate the effects of thickness and strengths of steel tube, axial compression ratio and damage degree on the fire resistance of circular CFST columns. Based on the analysis on experimental and numerical results, the loading mechanism of circular CFST columns is discussed. A design method is proposed for the prediction of fire resistance time under different seismic pre-damage and compression loads. The predictions by the new method is compared with the newly generated experimental and numerical results and is found to be accurate and consistent with the mean value close to the unity and a coefficient of variation around 1%.

Variation of time-dependent convection beat transfer coefficients in beat transfer analysis at various initial beating rates of tunnel fire scenarios (요소제거모델을 활용한 열전달해석에서 터널 화재이력곡선의 초기가열구배에 따른 대류열전달계수의 변화)

  • Choi, Soon-Wook;Chang, Soo-Ho;Lee, Jun-Hwan;Ahn, Sung-Yol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.223-237
    • /
    • 2010
  • The initial heating rate is well known as one of the most influencing factors on the occurrence of spalling and the loss of strength in concrete after fire initiation. In this study, a series of fire tests were carried out at different initial heating rates to find out its effects on the deterioration of tunnel structural members. Heat transfer analyses combined with an element elimination model were also carried out to verify its applicability in the same conditions as the fire tests. Moreover, the convection heat transfer coefficients compatible with fire test results were derived from parametric studies. In this course, their time-dependent variations were also analyzed at different initial heating rates. Finally, a numerical formula to estimate the heat transfer coefficients at the various initial heating rates was proposed by the interpolation of the results of numerical analyses.

Comparison of the Effects of Straight and Twisted Heat Trace Installations Based on Three-dimensional Unsteady Heat Transfer (열선의 직선시공과 감기시공의 동파방지 효과 비교를 위한 3차원 비정상 수치해석)

  • Choi, Myoung-Young;Jeon, Byoung-Jin;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This paper numerically examines, straight and twisted electrical heat trace installations for their anti-freezing effects on water inside a pipe. The unsteady incompressible Navier-Stokes equations coupled with an energy equation were solved to compare the two installation methods. The heat conduction of the pipe with a heat source interacts with the natural convection of the water, and the conjugate heat transfer was considered using a commercial code (ANSYS-FLUENT) based on a SIMPLE-type algorithm. Numerical experiments, were done to investigate the isotherms and the vector fields in the water region to extract the evolutions of the minimum and maximum temperatures of the water inside the pipe. There was no substantial difference in the anti-freezing effects between the straight and twisted. Therefore, the straight installation is recommended after considering the damage and short circuit behavior of the electrical heat trace.

Thermal Characteristic and Failure Modes and Effects Analysis for Components of Photovoltaic PCS (태양광 발전 PCS 구성부품에 대한 열적특성 및 고장모드영향분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.1-7
    • /
    • 2018
  • This paper is analyzed for the thermal characteristics(1 year) of the 6 components(DC breaker, DC filter(including capacitor and discharge resistance), IGBT(Insulated gate bipolar mode transistor), AC filter, AC breaker, etc.) of a photovoltaic power generation-based PCS(Power conditioning system) below 20 kW. Among the modules, the discharge resistance included in the DC filter indicated the highest heat at $125^{\circ}C$, and such heat resulting from the discharge resistance had an influence on the IGBT installed on the rear side the board. Therefore, risk priority through risk priority number(RPN) of FMEA(Failure modes and effects analysis) sheet is conducted for classification into top 10 %. According to thermal characteristics and FMEA, it is necessary to pay attention to not only the in-house defects found in the IGBT, but also the conductive heat caused by the discharge resistance. Since it is possible that animal, dust and others can be accumulated within the PCS, it is possible that the heat resulting from the discharge resistance may cause fire. Accordingly, there are two options that can be used: installing a heat sink while designing the discharge resistance, and designing the discharge resistance in a structure capable of avoiding heat conduction through setting a separation distance between discharge resistance and IGBT. This data can be used as the data for conducting a comparative analysis of abnormal signals in the process of developing a safety device for solar electricity-based photovoltaic power generation systems, as the data for examining the fire accidents caused by each module, and as the field data for setting component management priorities.

Economic effect analysis of flame retardant aluminum screen development

  • Park, Bum-Soon;Han, Chung-Soo;Kang, Tae-Hwan;Lee, Hee-Sook
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.3
    • /
    • pp.496-505
    • /
    • 2016
  • The purpose of this study was to investigate the economic effects of a flame retardant aluminum screen developed by a company Economic effects were analyzed in terms of micro and macro-economic aspects. In the macro-economic aspect, economic effects were analyzed under the assumptions that the total import volume of flame retardant aluminum screen was approximately $50m^2$ in 2015 and that possible import substitution rates were 100%, 80%, and 60%. Results showed economic values of 2.25 billion won (100% import substitution rates), 1.8 billion won (80% import substitution rates), and 1.35 billion won (60% import substitution rates). If existing farms which had been using imported flame retardant aluminum screen replaced it newly developed with the flame-retardant aluminum screen developed in this study at rates of 100%, 80%, and 60%, the farms could save 750 million won, 60 million won, and 45 million won, respectively. Furthermore, the social cost savings from fire prevention could be 1.184 billion won. In the micro-economic aspect, if a farm with a typical-size ($1,000m^2$) greenhouse growing red pepper wanted to install flame retardant aluminum screen instead of generic aluminum screen, the farm may only pay an additional cost of 720,000 won. In comparison, if the farm chose fire insurance instead of flame-retardant aluminum screen, then the farm would pay 21,000,000 won for fire insurance. The above results show that the economic effect of flame retardant aluminum screen developed by the company would be be very efficient compared to the imported one.