• Title/Summary/Keyword: fire effects

Search Result 860, Processing Time 0.028 seconds

Realtime Fire Simulation and Rendering on Mobile Environment (모바일 환경에서 불꽃의 실시간 시뮬레이션과 렌더링)

  • Woo, Sang-Hyuk;Jo, Mi-Ri-Na;Park, Dong-Gyu
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.7
    • /
    • pp.934-943
    • /
    • 2007
  • This paper presents a real-time fire simulation on the mobile phone using stable fluid animation techniques. Stable and fast fluid simulation methods are developed in PC and console games, but fluid simulation and interactive fluid models require too much system resources for applying on mobile environment. We studied and implemented physics-based models for fluids like fire and smoke effects using billboard and stable fluids simulation method on mobile 3D system. The mobile platform of our system is WIPI, which is the standard mobile platform in Korea, also we adopted NF3D API for our 3D programming API. We implemented real-time fire simulation and added it in mobile 3D game, "Rupee Story".

  • PDF

Development of Packed Bed Lung Model for the Deposition Studies of Fire Smoke (흡입연기의 침착 실험을 위한 충전층 폐모델 개발에 관한 연구)

  • Goo, Jae-Hark
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.121-128
    • /
    • 2008
  • Adverse health effects of inhaled smokes are associated with the amount of the particles deposited in human lung. Lung model is needed to simulate smoke deposition because of the hardness of the in vivo deposition experiment. However, it is hard to realize the successively decreasing bifurcations in the model. In this work, an experimental lung model was developed to simulate the smoke deposition in the lung. Instead of bifurcating airways, the lung model was made of packed beds of which size decreased downwards. The experimental results using this model showed good agreements with existing results for real lung in the deposition characteristics. The model could be applied to the studies of health risk assessment of the inhaled smoke particles generated by fire.

Simulation of the Brownian Coagulation of Smoke Agglomerates in the Entire Size Regime using a Nodal Method (결절법을 이용한 전영역에서의 연기입자 응집체에 대한 브라운응집현상 해석)

  • Goo, Jae-Hark
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.681-691
    • /
    • 2011
  • The size distributions of smoke particles from fire are prerequisite for the studies on fire detection and adverse health effects. Above the flame of the fire, coagulation dominates and the smoke particles grow from 1 to 50 nm up to 100 to 3,000 nm, sizes ranging from the free-molecular regime to the continuum regime. The characteristics of the agglomeration of the smoke particles are well known, independently for each of the free-molecular and continuum regimes. However, there are not many systematic studies in the entire regime by the complexity of the mechanisms. The purpose of this work is to find the characteristics of the development of the size distribution of smoke particles by agglomeration in the entire size range covering the free-molecular regime, via transition regime, to the near-continuum and continuum regime for each variation of parameters such as fractal dimension, primary particle size and dimensionless coagulation time. In this work, the dynamic equation for the discrete-size spectrum of the particles was solved using a nodal method based on the modification of a sectional method. In the calculation, the collision frequency function for the entire regime, which is derived by using the concept of collision volume and general enhancement function, was applied. The self-preserving size distribution for the entire regime is compared with the ones for the free-molecular or continuum regimes for each variation of the parameters.

Russian Forest Fire Smoke Aerosol Monitoring Using Satellite and AERONET Data (인공위성 자료와 AERONET 관측자료를 이용한 러시아산불 시 발생한 에어로졸의 중장거리 모니터링)

  • 이권호;김영준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.437-450
    • /
    • 2004
  • Extensive forest fire activities occurred across the border in Russia, particularly east of Lake Baikal between the Amur and Lena rivers in May 2003. These forest fires released large amounts of particulates and gases into the atmosphere, resulting in adverse effects on regional air quality and the global radiation budget. Smoke pollution from the Russian fires near Lake Baikal was transported to Korea through Mongolia and eastern China. On 20 May 2003, a number of large fires were burning in eastern Russian, producing a thick, widespread pall of smoke over much of Northeast Asia. In this study, separation technique was used for aerosol retrieval application with imagery from MODIS aboard TERRA satellites. MODIS true-color image shows the location of fires and the grayish color of the smoke plumes over Northeast Asia. Aerosol optical thckness (AOT) retrieved from the MODIS data were compared with fire hot spots, ground-based radiation data and TOMS -based aerosol index data. Large AOT, 2.0-5.0 was observed on 20 May 2003 over Korea due to the influence of the long range transport of smoke aerosol plume from the Russian fires, while surface observed fine mode of aerosol size distribution increased.

Optimum Management Plan of the HVAC Equipments with LCC Analysis (LCC 분석을 통한 공기조화 열원설비의 최적 관리방안)

  • Kim, Yong-Ki;Woo, Nam-Sub;Kang, Sung-Ju;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.556-562
    • /
    • 2008
  • The building HVAC systems have very different qualities of performance and durability with the superintendent's ability for management and maintenance. The poor management of these systems finally lead to the shortening of the life expectancy and result in the increase of operating costs and energy consumptions due to low efficiencies. This study presents an example of appropriate use of the LCC(Life Cycle Cost) analysis in a process of maintaining and repairing old HVAC equipments, by demonstrating the difference of optimal economic life, decrease of running cost, and energy consumption according to the management level of the HVAC equipments. But there are no reliable life expectancy and performance history data at present for optimal management of various building service equipments. Therefore, it is necessary to construct long-term database on operation results of them for more accurate and optimized LCC analysis.

Effects of Different Restoration Practices on Nutrient Loss from Sediments after a Forest Fire in Two Watersheds

  • Hwang, Tae-Hwan;Lee, Kyu-Song;Park, Sang-Deog;Choung, Yeon-Sook
    • Journal of Ecology and Environment
    • /
    • v.30 no.3
    • /
    • pp.265-269
    • /
    • 2007
  • The loss of nitrogen and phosphorus from sediments in two watersheds, one naturally regenerating and one artificially planted, in Sacheon-myun, Gangneung-si, Gangwon Province, were measured two years after a forest fire in 2000. Sediment losses occurred five times in the course of the year. In the artificially planted watershed, $50{\sim}140$ times more nitrogen and $54{\sim}139$ times more phosphorus were lost with sediments during heavy rains, from July to August, than in the naturally regenerating watershed. When the typhoon Rusa struck the country, 1,389 times more nitrogen and 1,647 times more phosphorus were lost from the artificial watershed. In spite of the limited scope of this study, these results suggest that artificially planted watersheds are extremely vulnerable to catastrophic natural disasters such as typhoons. Elevated loss of nutrients in the artificially planted watershed might have resulted from the mechanized silvicultural practices employed immediately after the fire. To maximize soil preservation, the timing and necessity of plantation practices should be reconsidered, and rapidly regenerating vegetation should be protected to promote nutrient uptake and to mitigate nutrient loss from burned forests.

Simplified robustness assessment of steel framed structures under fire-induced column failure

  • Jiang, Binhui;Li, Guo-Qiang;Yam, Michael C.H.
    • Steel and Composite Structures
    • /
    • v.35 no.2
    • /
    • pp.199-213
    • /
    • 2020
  • This paper proposes a Global-Local Analysis Method (GLAM) to assess the progressive collapse of steel framed structures under fire-induced column failure. GLAM obtains the overall structural response by combining dynamic analysis of the heated column (local) with static analysis of the overall structure (global). Test results of two steel frames which explicitly consider the dynamic effect during fire-induced column failure were employed to validate the proposed GLAM. Results show that GLAM gives reasonable predictions to the test frames in terms of both whether to collapse and the displacement verse temperature curves. Besides, several case studies of a two-dimensional (2D) steel frame and a three-dimensional (3D) steel frame with concrete slabs were conducted by using GLAM. Results show that GLAM gives the same collapse predictions to the studied cases with nonlinear dynamic analysis of the whole structure model. Compared with nonlinear dynamic analysis of the whole structure model, GLAM saves approximately 70% and 99% CPU time for the cases of 2D and 3D steel frame, respectively. Results also show that the load level of a structure has notable effects on the restraint condition of a heated column in the structure.

Strength Characteristics of Passive Fire Protection Material Applied Structural Members on Fire Load (수동화재보호 재료가 적용된 구조부재의 화재하중에 대한 강도 특성)

  • Jo, Sang Chan;Yu, Seung Su;Seo, Jung Kwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.1
    • /
    • pp.29-38
    • /
    • 2022
  • In offshore installations, fires cause the structure to lose its rigidity and it leads to structural integrity and stability problems. The Passive Fire Protection (PFP) system slows the transfer rate of fire heat and helps prevent the collapse of structures and fatality. Especially, intumescent epoxy coating is widely used in the offshore industry, and not only is the material cost expensive, but it also takes a lot of time and cost for construction. Several studies have been conducted on the efficient application and optimal design of the PFP system. However, the mechanical properties and the strength of the PFP material have not been considered. In addition, researches on the correlation between the thickness of PFP and the structural behavior were insufficient. Therefore, this study aims to analyze the thermal and mechanical effects of the PFP on the structure when it is applied to the structural member. In particular, it is intended to resolve the change in strength characteristics of the structural members as the thickness of the PFP increases.

Fire Damaged Behavior of Real Sized Normal Strength RC Columns (화해를 입은 실물크기 보통강도 RC 기둥의 거동)

  • Lee, Cha-Don;Shin, Yeong-Soo;Hong, Sung-Gul;Lee, Kyung-Ku;Lee, Seung-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.866-876
    • /
    • 2003
  • Experiments were performed for the real sized 12 reinforced concrete columns of 350${\times}$350${\times}$3350 mm with normal concrete in order to observe the fire-damaged behavior of these columns. Columns were heated according to the ISO heating curve. Main experimental parameters were: magnitude of axial load, heating time, cover thickness, and eccentricity. Effects of these parameters on the axial expansion and contraction, rotation, buckling, ISO fire resistance, and structural stability were experimentally quantified. It has been observed that the contraction rate of axial deformation was affected mostly by the duration of heating time and buckling of reinforcement or member by the magnitude of axial load, duration of heating time, cover thickness and eccentricity in order. Based on the experimental observations, ISO fire resistance criteria were qualiatively criticized.

Study on Reality of Field Practice and Improvements by Students of Dep. of Emergency Medical Technology (응급구조과 학생 현장실습의 실제와 개선방안 연구)

  • Kwon, Hayrran
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.15-26
    • /
    • 2002
  • As a result of analyzing problems in field practice and its effects, the following conclusions can be obtained. Man students were more satisfied with their choice of this department than woman students and woman students recognized the importance of hospital practice although they felt the need of fire fighting station practice and man students felt the necessity of hospital practice, but they answered the fire fighting station practice was important. Departments of field practice are emergency and nurse departments in hospitals and emergency aid section in fire fighting stations. And it is found that field practice was performed well in relation to major subject. Areas of practice included emergency room, operation room and extensive cure unit and the experience of ambulance was more in fire fighting station than in hospital. Clinical guidance of professor was preferred to once a week and the students answered they felt satisfaction with practice through conference. Answer that field practice was helpful in understanding class was very high as 96.8% and its connection with employment was low as 12.8%. It is found that a proper timing of field practice was winter vacation for hospital practice after completing the second semester of the first year and summer vacation for fire fighting station practice after the first semester of the second year. The most difficult department in field practice was nurse department in hospital because 'respondents were practice students' and administrative department in fire fighting stations because 'they lacked recognition of paramedic'. In making practice diary, 'describing measure results' was difficult most and the respondents wanted to keep the diary in their custody.

  • PDF