• Title/Summary/Keyword: fire effects

Search Result 860, Processing Time 0.025 seconds

Problem Analysis of Power Capacity and Main Line Voltage Drop of Electric Power System for Fire Protection (소방전원계통의 전원용량과 간선의 전압강하에 대한 문제점 분석)

  • Choi, Seung-Kyou;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.53-58
    • /
    • 2015
  • The number of high-rise buildings and skyscrapers has increased drastically, and accordingly, the power capacities and main line lengths of electric power systems for fire protection are also rapidly increasing. This is generating new of problems like shortages in power capacities and increases of main line voltage drops outside of the rated voltage range. This problem can have serious effects on fire protection systems and a variety of electric devices may not work properly in emergencies. As such, theoretical calculations were performed for these systems in an actual fire protection facility. The problems in the electric power system were extracted and analyzed, and the results show that it is necessary to search for new measures for the safe and rational design and operation of electric power systems for fire protection.

Prediction of the Effects of the Ship's Heel and Trim Conditions on the Fire Development Characteristics (선박의 종경사 및 횡경사 변화가 화재 확산에 미치는 영향 예측)

  • Kim, Byeol;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.42 no.4
    • /
    • pp.283-290
    • /
    • 2018
  • Due to the environmental factors of the sea, ship accidents always contain an inclination angle. The change in the ship affects not only the evacuation speed of passengers but also the fire growth in the ship. For this reason, when analyzing the fire, it is necessary to analyze the risks by considering conditions of inclination. In this study, the temperature that affects the fire was calculated by alteration of ship's heel and trim angle and analyzed using FLUENT. Based on fire occurrence position, evacuation should be done within 37 seconds under the condition of $-10^{\circ}$ heeling angle and 36 seconds under the condition of $-10^{\circ}$ trim angle. However, it was predicted that the evacuation will not be affected under the conditions of $+10^{\circ}$ heel angle and $+10^{\circ}$ trim angle. For these reasons, it is confirmed that when the ship is on fire, evacuation measures should be considered based on the heel and trim conditions as per the location of the fire.

A Comparative Study on the Toxicity Evaluation for Fire Smoke by FDS (FDS를 이용한 화재시 연소가스의 독성평가에 관한 비교 연구)

  • Jeong, Beom Jin;Lee, Keun Won
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • FDS (Fire Dynamics Simulator) is the most widely used computational fluid dynamics software in the fire safety engineering community, and it is applicable to various evaluations of fire growth and its effects. This study made use of a range of outputs from FDS simulation to predict FED (Fractional Effective Concentration) and FEC (Fractional Effective Concentration) levels which are often adopted to evaluate toxicity of fire smoke. As it is not possible to calculate these values directly from outputs of FDS, it was necessary to produce them by means of additional calculation procedures incorporating results of evacuation simulation. In this study, the latest version of FDS, which was recently updated in November 2013, was utilized for the purpose of quantitative comparison with the old version of FDS. As a result, it was found that they make about 10 percent difference on average in predicting FED and FEC levels for the cable fire case study.

Analysis of restrained steel beams subjected to heating and cooling Part I: Theory

  • Li, Guo-Qiang;Guo, Shi-Xiong
    • Steel and Composite Structures
    • /
    • v.8 no.1
    • /
    • pp.1-18
    • /
    • 2008
  • Observations from experiments and real fire indicate that restrained steel beams have better fire-resistant capability than isolated beams. Due to the effects of restraints, a steel beam in fire condition can undergo very large deflections and the run away damage may be avoided. In addition, axial forces will be induced with temperature increasing and play an important role on the behaviour of the restrained beam. The factors influencing the behavior of a restrained beam subjected to fire include the stiffness of axial and rotational restraints, the load type on the beam and the distribution of temperature in the cross-section of the beam, etc. In this paper, a simplified model is proposed to analyze the performance of restrained steel beams in fire condition. Based on an assumption of the deflection curve of the beam, the axial force, together with the strain and stress distributions in the beam, can be determined. By integrating the stress, the combined moment and force in the cross-section of the beam can be obtained. Then, through substituting the moment and axial force into the equilibrium equation, the behavior of the restrained beam in fire condition can be worked out. Furthermore, for the safety evaluation and repair after a fire, the behaviour of restrained beams during cooling should be understood. For a restrained beam experiencing very high temperatures, the strength of the steel will recover when temperature decreases, but the contraction force, which is produced by thermal contraction, will aggravate the tensile stresses in the beam. In this paper, the behaviour of the restrained beam in cooling phase is analyzed, and the effect of the contraction force is discussed.

State-of-the-Art Research and Experimental Assessment on Fire-Resistance Properties of High Strength Concrete (고강도 콘크리트의 내화 특성에 관한 기존연구 고찰 및 실험적 연구)

  • Kim, Woo-Suk;Kang, Thomas H.K.;Kim, Wha-Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.28-39
    • /
    • 2014
  • This paper reviews past literatures relevant to fire-resistance properties of high strength concrete and investigates spalling mechanism of high strength concrete in fire. First, literatures were reviewed on spalling occurrence and fire-resistance methods. Second, a chemical change of concrete components in an elevated temperature was presented. Finally, the mechanism of the spalling occurrence and spalling resistance were examined in terms of hybrid fiber content. The focus of the experimental study as part of this research is to investigate the effects of fire on the variation of thermal properties of high strength concrete, which tends to be used in super tall buildings. This experimental study was devised to investigate the fire-resistance performance of high strength concrete containing hybrid fibers. A total of 48 test specimens were exposed to high temperature ranging from $100^{\circ}C$ to $700^{\circ}C$, including room temperature (${\sim}20^{\circ}C$). Test results provide valuable information regarding fire-resistance properties of strength concrete with 100 MPa or greater.

The Transfer Characteristics of $CO_2$ Extinguishant According with the Location of Fire Plume (화재위치에 따른 $CO_2$소화제 전달특성)

  • 박찬수;최주석
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2003
  • To analyze the transfer characteristics of $CO_2$ extinguishant when extinguishant is injected into a closed space similar to a marine engine room, a numerical simulation was performed. Flow and Concentration fields are calculated according with the variation of the fire plume,s location. The results show that tile variation of fire plumes, location greatly effected on the flow patterns and the characteristics of $CO_2$ extinguishant transfer. In case of the fire plume located at left region of the 2nd floor center in the engine room consisted of first and second floor, The effects similar to the air curtain is found and cut off the mass transfer. In the characteristics with hight, the iso-concentration line below the extinguishable limit is formed in the left region of the 1st and 2nd floor center after the $CO_2$ extinguishant is completely injected. therefore I think that the results of this study are considered to arrange the $CO_2$ injection nozzles for the $CO_2$ fire fighting equipments.

Numerical Modeling of Residual Behavior of Fire-Damaged Reinforced Concrete Interior Columns (화해를 입은 철근콘크리트 내부기둥의 잔존거동 수치해석 모델)

  • Lee Chadon;Shin Yeong-Soo;Lee Seung-Whan;Lee Chang-Eun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.893-902
    • /
    • 2005
  • Reasonable prediction of residual capacity of fire-damaged reinforced columns is important for both the safety measurement and the rehabilitation of the reinforced concrete structures suffered from exposure to extensive fire. In order to predict the residual behavior of fire-damaged reinforced concrete columns, its predictive model must be able to take into account the amount of heat transferred into the column, the level of deterioration of constituent materials and various column geometries. The numerical model presented in this research includes all these factors. The model has been shown to reasonably predict the residual behavior of fire-damaged columns. Parametric studies were performed using this model for the effects of cover thickness, exposure time to fire and column geometries on the residual behavior of reinforced concrete columns. It was found that serious damage on the residual capacity of column resulted from a longer exposure time to fire but only marginal differences from other factors.

Effects of job satisfaction and spouse support on parenting stress in female fire fighters with preschool-aged children (취학 전 자녀를 둔 여성소방공무원의 직무만족도와 배우자 지지가 양육스트레스에 미치는 영향)

  • Che, Ga-Young;Baek, Mi-Lye
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.1
    • /
    • pp.87-98
    • /
    • 2015
  • Purpose: Job satisfaction, spouse support, parenting stress, and the factors that influence parenting stress in female fire fighters with preschool-aged children were examined. Methods: Data were collected from 180 female fire fighters who worked at the fire station from June to July 2013 and had preschool-aged children. Data were analyzed using SPSS WIN 21.0. Results: Average job satisfaction was 2.81, spouse support was 3.54, and parenting stress was 3.61. Parenting stress was negatively correlated with spouse support and job satisfaction. Job satisfaction and spouse support were positively correlated. Factors influencing parenting stress included employment period (${\beta}$=0.093, p <.05), a husband who is not a fire fighter (${\beta}$=-8.971, p <.05), having three children (${\beta}$=27.395, p <.05), delegating childcare to relatives (${\beta}$=9.605, p <.05), income (${\beta}$=-0.920, p <.05), and spouse support (${\beta}$=-0.589, p <.05). Conclusion: To reduce parenting stress and increase job satisfaction, female fire fighters with preschool-aged children should be assigned to stable administrative work instead of stressful on-site work. Husbands who are fire fighters should take advantage of paternity leave, implemented by the Ministry of Public Safety and Security, to increase their active participation in parenting.

Some Effects of Fire on Vegetation, Soil and Soil Microflora adjacent to DMZ in Korea (식생, 토양 및 토양미생물에 미치는 불의 효과에 대하여)

  • 홍순우
    • Journal of Plant Biology
    • /
    • v.11 no.4
    • /
    • pp.9-20
    • /
    • 1968
  • In general there are few cases which were caused by lightening and no fire was observed to have been caused but by artificial or accidental fires during preliminary survey. And then the most scales of burning in Korea are like the fig. 2. Temperature 5 cm apart from flame at the burning site were known to range from 165$^{\circ}$to 20$0^{\circ}C$ in surface fire on Myozangdong, pine-quercus dominant community and from 120$^{\circ}$ to 145$^{\circ}C$ in surface fire of Wolwoonni, Mischanthus dominant area and from 120$^{\circ}$ to 14$0^{\circ}C$ in ground fire of Wangzinkun, Mischanthus dominant, respectively. Through the preliminary survey, fire indicater plants in Korea were confirmed as Mischanthus coreensis Hack and Carex alterifolia Franch. The plants of highest frequency appeared in the burnt sites were known to as Potentilla cryptotaeniae Max, Mischanthus coreensis Hack, Carex alterifolia Franch and Artemisia brachyphylla Kitamura. Lespedezas were proved as one of the fire tolerant and Pinus densiflora was found out as the lowest intolerant plant to fire. The acidity of burnt soil was decreased according to the considerable amount of ash left on the ground. The acidity of surface soil was more decreased than the below 10cm of soil. The chemical composition(NO3, P, K, Mg, Total-N and Organic-C) of burnt soil was more increased than those of the unburnt sites. And the population changes of soil microflora seemed to have a certain tendency. The population of soil microflora was increased a little according to climatic conditions. Also there was an initial decrease in the population of microflora followed immediately by a significant increase.

  • PDF

Fire Resistance Performance of Load Bearing Hybrid Panel Infilled with Light-weight Formed Mortar (복합스터드에 경량기포모르터를 충전한 내력벽체의 내화성능 비교연구)

  • Park, Keum Sung;Bae, Kyu Woong;Kang, Hyun Sik;Lim, Seo Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2007
  • The purpose of this paper is to evaluate the fire resistant performances of load-bearing wall using both composite and steel stud panel infilled with light-weight formed mortar under axial loading according to KS F 2257(1999). The minimum requirement of 2 hours fire resistant rating is needed for the residential and commercial buildings under the fire regulation of Korea. From test results, it is found that two types of specimen composed of the hybrid stud and steel stud panel filled with light-weight formed mortar fited in with the requirement of 2 hours fire resisting rate for the load-bearing wall. In the conclusions, the specimen with hybrid stud shows predominating fire-resistant performance on the adiabatic effects rather than that of the steel stud specimen.