• Title/Summary/Keyword: fire disaster

Search Result 1,918, Processing Time 0.021 seconds

DB Construction of Activation Temperature and Response Time Index for Domestic Fixed-temperature Heat Detectors in Ceiling Jet Flow (천장제트기류에 대한 국내 정온식 열감지기의 작동온도 및 반응시간지수(RTI)에 관한 DB 구축)

  • Yoon, Ga-Yeong;Han, Ho-Sik;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.35-42
    • /
    • 2020
  • The accurate prediction of fire detector activation time is required to ensure the reliability of fire modeling during the safety assessment of performance-based fire safety design. The main objective of this study is to determine the activation temperature and the response time index (RTI) of a fixed heat detector, which are the main input factors of a fixed-temperature heat detector applied to the fire dynamics simulator (FDS), a typical fire model. Therefore, a fire detector evaluator, which is a fire detector experimental apparatus, was applied, and 10 types of domestic fixed-temperature heat detectors were selected through a product recognition survey. It was found that there were significant differences in the activation temperature and RTI among the detectors. Additionally, the detector activation time of the FDS with the measured DB can be predicted more accurately. Finally, the DB of the activation temperature and RTI of the fixed-temperature heat detectors with reliability was provided.

A Study on the Risks Factors of Fire Occurrence and Expansion for Traditional Markets (전통시장 화재 발생 및 확대 위험요인에 관한 연구)

  • Kim, Jung-Gon;Park, Chang-Il;Jung, Jae-Wook;Kim, Seong-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • Purpose: Traditional markets often have irregular space utilization patterns because the spaces are created and divided as time passed. Internally, there is high risk of fire due to problems such as aging facilities and high-density of stores and externally, there is high risk of fire spread since it is often adjacent to deteriorated residential and commercial facilities. Method: In this paper, on-site investigations were carried out to check fire risk factors and fire spread risk, and fire occurrence and expansion risk factors were investigated for traditional markets in Hwanghak-dong and Dong-daemun by using large-scale fire data from existing traditional markets. Result: As a result of the analysis, there are likely to be various problems such as high fire load and lack of safety awareness due to aging facilities and high-density of stores. In particular, it is necessary to prepare countermeasures because deteriorated residential facilities with narrow alleys around traditional markets have high fire spread. It is situation that while traditional markets mainly are managing for fire and disaster centering on the merchant association, the surrounding residential areas are not properly managed. Conclusion: It is necessary to manage deteriorated residential facilities with traditional markets, also to be linked early warning system and information to evacuate rapidly in case of fire there.

A Study on the Thermal Characteristics Depending on Poor Contact of Wire Connection Part in Terminal Block (단자대 전선접속개소의 접촉불량에 따른 발열특성에 관한 연구)

  • Park, Sang-Min;Jee, Seung-Wook;Kim, Si-Kuk;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.48-51
    • /
    • 2011
  • 본 논문은 나사조임 단자대 내에 접속되는 전선의 접촉불량에 따른 발열특성을 분석하고자 단자대 접속개소의 조임토크를 KS C 2625에서 규정한 정상조임토크와 인위적인 불량조임토크를 변수로 설정하여 조임토크의 크기별로 동일한 부하를 인가한 후, 열화상카메라를 이용하여 접속불량에 따른 발열특성을 비교 분석하였다.

  • PDF

A Case Analysis and Research Trends of FDS in Domestic (국내 FDS연구동향 및 적용사례분석)

  • Kim, Bong-Chan;Lee, Rang;Kim, Dong-Eun;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.15-18
    • /
    • 2011
  • 본 연구는 국내 FDS연구동향 및 적용사례를 분석한 것으로서, 분석한 결과 FDS는 법의 개정 및 화재사고와 밀접한 관계를 가지는 것으로 판단되었다. 또한 FDS 수치해석시의 격자 민감도, 벽면의 난류유동 등의 문제점이 파악되어, 향후 개선되어야 할 것으로 판단된다.

  • PDF

A Study on Fluidized Bed Process Powder Coating Insulation and Electrical Degradation Properties for Bus Duct (부스닥트용 유동침적방식의 절연 및 열화 특성연구)

  • Kang, Chul-Hwa;Choi, Ji-Hyun;Park, Ji-Kun;Ju, Hyun-Don;Kim, Hyun-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.413-416
    • /
    • 2011
  • 대용량 기기의 효율적인 전력 공급을 위해 부스닥트의 수요가 급증하고 있으며, 특히 컴팩트형 부스닥트는 케이블에 비해 무게와 부피가 가볍고 전력 효율도 25% 이상 우수하며, 기술의 핵심은 에폭시분체도료의 절연 특성 향상과 제작공정의 최적화와 안정화이다. 따라서 본 연구에서는 유동침적방식(Fluidized Bed Process)에 대한 최적화와 에폭시 분체도료의 절연설계 및 열화특성에 대해 실험 검토 하였다. 또한 전기화재의 주된 원인인 아크방전특성과 절연파괴 특성에 대한 분석과 더불어 다양한 상용제품들의 특성을 비교하였다.

  • PDF

A Study on the Cone Calorimeter and Furniture Calorimeter using Residential Combustible Combustion Characteristics (Cone Calorimeter와 Furniture Calorimeter를 활용한 주거시설의 대표적 가연물 연소 특성)

  • Kim, Dong-Eun;Kim, Bong-Chan;Lee, Jae-Won;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.193-196
    • /
    • 2011
  • 본 연구는 주거시설의 대표적인 가연물을 고정가연물과 적재가연물로 구분하여 가연물의 연소특성을 실험결과에 대한 연구이다. 고정가연물은 7종에 대하여 Cone Calorimeter로 적재가연물은 2종 Furniture Calorimeter로 실험을 실시하였다. 고정가연물의 경우 접착성분을 지니고 있는 시트지의 경우가 HRR등이 높게 측정되었으며, 적재가연물의 경우 섬유성분과 플라스틱으로 구성되어 있는 의자가 높게 측정되는 것을 알 수 있었다.

  • PDF