• Title/Summary/Keyword: fire curve

Search Result 200, Processing Time 0.03 seconds

Studies on the Residual Bending Strength of burned Douglas-fir and Western Hemlock soaked with Fire Retardant Chemicals (내화처리(耐火處理) 미송(美松) 및 미삼재(美杉材)의 연소후(燃燒後) 잔유(殘留)휨강도(强度)에 관한 연구(硏究))

  • Lee, Phil-Woo;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.15-24
    • /
    • 1984
  • The $3{\times}3{\times}30\;cm^3$ sized specimens of Douglas-fir(Pseudotsuga menziesii) and western hemlock(Tsuga heterophylla) in this study were soaked in four fire-retardant solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, and aluminium chloride for 1, 24, 72, 168, and 336 hours. Subsequently they were air-dried and burned at high temperature of ca. $1,800^{\circ}C$ and for short time of 5 minutes. This study estimated the relationship between the adsorbed chemicals and the residual weight ratio or residual bending strength of these partly burned lumbers. The results were as follows; 1) In average amount of chemical adsorption, diammonium phosphate showed the largest and aluminium chloride the smallest regardless of species but monoammonium phosphate was larger in Douglas-fir than that of western hemlock. 2) The amount of chemical adsorption was larger in western hemlock than Douglas-fir on the whole. 3) The amount of chemical adsorption was increased with the increase of soaking time but the rate of increase began to decrease at 200hrs. 4) Residual weight ratios showed no difference between species but showed differences among the chemicals treated i.e. monoammonium phosphate, diammonium phosphate, ammonium sulfate and aluminium chloride in turn from the largest to the smallest. 5) MOR values showed linear increase with the increase of residual weight ratios but showed no difference in species and chemicals respectively. 6) In the relationship between amount of chemical adsorption and MOR, only diammonium phosphate showed the curve of secondary degree with significance in Douglas-fir. 7) The MOE value of burned Douglas-fir lumber increased and showed significance of 99% as the adsorbed chemical amount increased, but among the chemicals only monoammonium phosphate showed significance. The MOE value of burned western hemlock lumber didn't show significance. 8) In only Douglas-fir, the correlation between adsorbed chemical amount and work to proportional limit showed significance in only monoammonium phosphate. And in both Douglas-fir and western hemlock, the correlation between adsorbed chemicals and work to maximum load showed significance in monoammonium phosphate.

  • PDF

Response Characteristic of HVDC System According to Frequency Sensing Methods (주파수 측정방법에 따른 HVDC시스뎀의 응답특성)

  • Kim C,K;Yang B.M;Park J.G.;Jeong G.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.299-303
    • /
    • 2003
  • This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system areto fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the synchronous machine and the second method is from AC network. Two methods have advantages and disadvantage each other. For the extreme case of a receiving system of zero inertia (no generation), synchronous machine is essential. In this situation, the frequency information received from the synchronous machine shaft. However, the speed of synchronous machine is oscillated when a disturbance in AC network occurs, and HVDC may be oscillated due to an oscillation speed. To solve this drawback, in this paper, new frequency sensing method is proposed. A proposed method that is use a modified curve-fitting algorithm, has a robust characteristics against a harmonics and unbalanced faults. Consequently, A proposed method is verified by PSCAD/EMTDC Program and experimental test.

  • PDF

A Comparison of Spinosin Content in Zizyphi Semen and Its Processed Products by Roasting (산조인의 수치에 따른 Spinosin 함량 비교)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Kim, Byoung-Soo
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.4
    • /
    • pp.360-365
    • /
    • 2016
  • The aim of this study was to compare the amount of spinosin in the 70% ethanol extracts of non-processed Zizyphi Semem (ZS) and processed ZS by roasting using a high-performance liquid chromatography equipped with photodiode array detector. Separation of the spinosin was used $SunFire^{TM}$ $C_{18}$ analytical column ($5{\mu}m$, $4.6{\times}150mm$) using two mobile phase consisting of distilled water and acetonitrile, both with 1.0% (v/v) acetic acid. The flow rate was 1.0 mL/min and injection volume was $10{\mu}L$. Calibration curve of the spinosin was y = 22339.45x+483.99 in tested concentration range ($1.28-20.00{\mu}g/mL$) and correlation coefficient was 1.0000. In non-processed ZS sample, the amount of the spinosin was 0.94 m/g, while, the amount of the marker compound in processed ZS samples were 0.66-1.10 mg/g.

The Measurement and Estimation of Lower Flash Point for o-Xylene+n-Pentanol and m-Xylene+n-Hexanol Systems Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 o-Xylene+n-Pentanol 계와 m-Xylene+n-Hexanol 계의 하부인화점 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sung-Jin;Jeong, Kee-Sin
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.19-25
    • /
    • 2010
  • The flash points for the systems, o-xylene+n-pentanol and m-xylene+n-hexanol, were measured by using Tag open-cup tester(ASTM D1310-86). The experimental data were compared with the values calculated by the Raoult's law and the optimization method using van Laar and Wilson equations. The calculated values based on the optimization method were found to be better than those based on the Raoult's law. The predictive curve of the flash point prediction model based on the van Laar equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the Wilson equation.

Methodological Consideration on the Prediction of Electrochemical Mechanical Polishing Process Parameters by Monitoring of Electrochemical Characteristics of Copper Surface

  • Seo, Yong-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.346-351
    • /
    • 2020
  • The removal characteristics of copper (Cu) from electrochemical surface by voltage-activated reaction were reviewed to assess the applicability of electrochemical-mechanical polishing (ECMP) process in three types of electrolytes, such as HNO3, KNO3 and NaNO3. Electrochemical surface conditions such as active, passive, transient and trans-passive states were monitored from its current-voltage (I-V) characteristic curves obtained by linear sweep voltammetry (LSV) method. In addition, the oxidation and reduction process of the Cu surface by repetitive input of positive and negative voltages were evaluated from the I-V curve obtained using the cyclic voltammetry (CV) method. Finally, the X-ray diffraction (XRD) patterns and energy dispersive spectroscopy (EDS) analyses were used to observe the structural surface states of a Cu electrode. The electrochemical analyses proposed in this study will help to accurately control the material removal rate (MRR) from the actual ECMP process because they are a good methodology for predicting optimal electrochemical process parameters such as current density, operating voltage, and operating time before performing the ECMP process.

A Study on Risk Assessment and Risk Mitigation Measures of Liquefied Chlorine Leak (액화염소 누출의 위험도 분석 및 위험경감조치에 대한 연구)

  • Lee, Ju-Youn;Chon, Young-Woo;Hwang, Yong-Woo;Lee, Ik-Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • As the chemical industry becomes more advanced, the awareness of chemical accidents is rising, and legal systems for chemical safety management are strengthened. In this study, quantitative risk assessment of liquid chlorine leak was conducted. Risk assessment was performed in the order of frequency analysis, consequence analysis, and risk calculation. The individual risk was presented in the form of contour lines. The social risk was expressed by the FN curve. The risk of day and night was in an unacceptable area, so it was required to mitigate risk. Therefore in-building, which could trap the pool, was selected as a risk mitigation measure. As a result of the cost benefit analysis, it was concluded that this measure should be reasonably implemented.

Rocking Behavior of Steel Dampers according to Strut Shapes and Heights of Steel dampers (강재 댐퍼의 스트럿 형상과 높이에 따른 록킹 거동)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.45-52
    • /
    • 2019
  • In this study, the seismic strengthening technique considering the rocking behavior of the wall was developed. The rocking system rotates left and right around the vertical axis of the wall. The development system is a method of dissipating energy by installing a damper which was attached at a large displacement portion. The damper was made of a steel material, and the shape and height of the strut were selected as variables. Experimental results showed that in case of shorter strut make strength capacity increasement and in case of longer strut make deformation capacity increasement. As a result of comparing the abilities according to I and S type strut shapes, it was evaluated that S type has better seismic performance.

A novel risk assessment approach for data center structures

  • Cicek, Kubilay;Sari, Ali
    • Earthquakes and Structures
    • /
    • v.19 no.6
    • /
    • pp.471-484
    • /
    • 2020
  • Previous earthquakes show that, structural safety evaluations should include the evaluation of nonstructural components. Failure of nonstructural components can affect the operational capacity of critical facilities, such as hospitals and fire stations, which can cause an increase in number of deaths. Additionally, failure of nonstructural components may result in economic, architectural, and historical losses of community. Accelerations and random vibrations must be under the predefined limitations in structures with high technological equipment, data centers in this case. Failure of server equipment and anchored server racks are investigated in this study. A probabilistic study is completed for a low-rise rigid sample structure. The structure is investigated in two versions, (i) conventional fixed-based structure and (ii) with a base isolation system. Seismic hazard assessment is completed for the selected site. Monte Carlo simulations are generated with selected parameters. Uncertainties in both structural parameters and mechanical properties of isolation system are included in simulations. Anchorage failure and vibration failures are investigated. Different methods to generate fragility curves are used. The site-specific annual hazard curve is used to generate risk curves for two different structures. A risk matrix is proposed for the design of data centers. Results show that base isolation systems reduce the failure probability significantly in higher floors. It was also understood that, base isolation systems are highly sensitive to earthquake characteristics rather than variability in structural and mechanical properties, in terms of accelerations. Another outcome is that code-provided anchorage failure limitations are more vulnerable than the random vibration failure limitations of server equipment.

Axial compression mechanical properties of steel reinforced recycled concrete column exposure to temperatures up to 800℃

  • Chen, Zongping;Liang, Yuhan;Mo, Linlin;Ban, Maogen
    • Steel and Composite Structures
    • /
    • v.41 no.5
    • /
    • pp.731-746
    • /
    • 2021
  • The purpose of this paper is to investigate the axial bearing capacity and residual properties of steel reinforced recycled aggregate concrete (SRC) column after elevated temperature. A total of 48 SRC columns were designed for the static loading test after elevated temperature. The variables include replacement ratios, designed temperature, target duration, thicknesses of cover concrete, steel ratios and stirrup spacing. From this test, the mass loss ratio and stress load-deformation curve were obtained, and the influence of various parameters on residual bearing capacity were analyzed. ABAQUS was used to calculate the temperature field of specimens, and then got temperature damage distribution on the cross-section concrete. It was shown that increasing of the elevated temperatures leaded to the change of concrete color from smoky-gray to grayish brown and results in reducing the bearing capacity of SRC columns. The axial damage and mechanism of SRC columns were similar to those of reinforced natural aggregate concrete columns at the same temperatures. Finally, the calculation method of axial compressive residual bearing capacity of SRC columns recycled concrete columns after high temperature was reported based on the test results and finite element analysis.

Studies on Press Drying of Fire-Retardant Treated Plywood (내화처리합판(耐火處理合板)의 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Kim, Jong Man
    • Journal of Korean Society of Forest Science
    • /
    • v.56 no.1
    • /
    • pp.1-25
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable and can cause fire accidents. causing destruction of human life and property. To diminish the fire disaster, fire retardant plywood is indeed required. In the methods of manufacturing the fire retardant plywood, a soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions redrying of soaked plywood is of the utmost importance. In this study 3.5mm and 5.0mm thickness plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid minalith, and water solution, 1-, 3-, 6-, and 9 hour-soaking treatments in borax-boric acid and minalith, and 6- and 9 hours in the other chemicals were applied and after the treatment hot drying was applied to treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$ of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1) In the 9 hours-soaking treatment of fire retardants by hot and cold bath method, the chemical retentions of 3.5mm thickness plywood could be attained within the range ($1.125-2.25kg/(30cm)^3$) of minimum retention specification as follows: $1.353kg/(30cm)^3$ in monoammonium phosphate, $1.331kg/(30cm)^3$ in diammonium phosphate, $1.263kg/(30cm)^3$ in ammonium sulfate, $1.226kg/(30cm)^3$ in borax-boric acid. But the chemical retention, $0.906kg/(30cm)^3$, in minalith could not be attained within the range of minimum retention specification. And also in case of 5.0mm thickness plywood, chemical retentions, as $1.356kg/(30cm)^3$ and $1.166kg/(30cm)^3$ respectively, of ammonium sulfate and diammonium phosphate could be attained within the range minimum retention specification, but the other fire retardant chemicals could not. 2) In the 6- and - hours-soaking treatments of 3.5mm and 5.0mm thickness plywood, the drying curve sloped of chemical treated plywood was smaller than that of water treated. The drying rate related to thickness of treated plywood, was about three times as fast in 3.5mm thickness plywood compared with 5.0mm thickness plywood. 3) In the treatment at $120^{\circ}C$ of hot platen temperature, the drying rates of chemical-treated plywood showed the highest quantity in diammonium phosphate of 3.5mm and 5.0mm thickness plywood. But the drying rate of water treated plywood was highest during the 6- and 9 hours-soaking treatments. 4) The drying rate remarkably increased with proportion to increase of the platen temperature, and the values were respectively 1.23%/min., 6.54%/min., 25.75%/min. in hot platen temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in 3.5mm thickness plywood and 0.55%.min., 2.49%/min., 8.19%/min. in hot platen temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in 5.0mm thickness plywood. 5) In the fire retardant degree of chemical treated plywood, the loss in weight was the smallest in diammonium phosphate, next was in monoammonium phosphate and ammonium sulfate, and the greatest was in borax-boric acid and minalith. And the fire-retardant effect in burning time, flame-exhausted time and carbonized area were greatest in diammouniun phosphate, next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric acid and minalith.

  • PDF