• 제목/요약/키워드: fire control time

검색결과 356건 처리시간 0.032초

A Comparative Functionality Evaluation of Paulownia Wood Storage Boxes and Acid-free Archival Boxes to Store the Annals of Joseon Dynasty - Indoor and Outdoor Temperature and Relative Humidity Controls, and Heat Release Rate -

  • Park, Hae Jin;Kim, Seong Eun;Lee, Jin Kyung;Chung, Yong Jae
    • 보존과학회지
    • /
    • 제38권1호
    • /
    • pp.72-79
    • /
    • 2022
  • A paulownia wood has been widely used with various advantages as its low weight, permeability, convenient workability and aesthetic patterns for a long time. However, the related empirical researches and simultaneous evaluations of functionality are insufficient compared with acid-free archival boxes for now. In this study, the indoor and outdoor temperature and relative humidity control and heat release rate were evaluated under the controlled and uncontrolled circumstance in 2018. The paulownia wood storage box showed superior control effect of relative humidity than the acid-free archival box in constantly uncontrolled environment. Also, the possibility of the flame diffusion from the surface of the materials was higher for the paulownia materials, and the acid-free archival box showed more dangerous patterns in the early stages of the fire.

LPG/CNG용 센서 모듈 및 관제시스템 S/W 개발 (Development of Sensor Module and Control System Software for LPG/CNG Stations)

  • 조범석;김승광;김성태;김종민
    • 한국가스학회지
    • /
    • 제22권1호
    • /
    • pp.53-59
    • /
    • 2018
  • 국내에 설치되어 있는 LPG 충전소는 약 2000개로 매년 26개씩 증가하고 있다. 이 중 15년 이상 된 노후화 된 충전소는 약 500개로 전체의약 25% 해당된다. 이 중 약 86%는 도시에 설치되어 있어 사고 발생 시 매우 큰 피해가 우려되고 있는 실정이다. 이에 따라, 본 논문에서는 LPG/CNG 충전소에서 가스 누출 및 화재 사고를 예방 및 대응 할 수 있는 가스센서 모듈 및 관제시스템을 개발하였다. 듀얼 타입 센서 모듈은 메탄, 부탄 및 수소의 센서에 측정 된 데이터를 FR433Mhz통신을 통하여 데이터를 수집하여, 전달할 수 있는 기능을 가지고 있다. 또한, 각각의 센서는 두 개씩 부착되어 안정성 및 정확도를 높였다. 통합관제시스템의 S/W는 센서에서 측정 된 장치의 실시간 데이터를 감지하고, 위험상황 발생 시 PC와 스마트폰으로 전달하여 위험 경보를 관리자가 시간과 장소에 상관없이 충전소의 상황을 확인 할 수 있도록 하였다.

가속수명시험(ALT)을 이용한 WOLED의 성능 및 신뢰성 평가 (Evaluation of Performance and Reliability of a White Organic Light-Emitting Diode(WOLED) Using an Accelerated Life Test(ALT))

  • 문진철;박형기;최충석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.13-19
    • /
    • 2012
  • The purpose of this study is to extract the major factors related to the deterioration mechanism of white organic light-emitting diodes(WOLED) by performing accelerated testing of temperature, voltage, time, etc., and to develop an accelerated life test(ALT) model. The measurement results of the brightness of the WOLED exhibited that their average brightness tended to increase as the operating voltage increased and that the half-life period of the brightness appeared after approximately 400 hours when the operating voltage was 20V and the ambient temperature was $85^{\circ}C$. It could be seen that although the WOLED showed comparatively the same brightness when the initial acceleration began after the operating voltage was applied to it, its brightness changed excessively after the WOLED's thermal storage had been made. In addition, it was observed that the half-life period was reduced as the ambient temperature and applied voltage increased. The strength of the WOLED which had been maintained in the range of visible light at the maximum load was reduced by the deterioration of the organic light emitting material due to the influence of the operating voltage and temperature, and the reduction of emitted light was small at low voltage and temperature. It could be seen that the failure of the WOLED during the ALT was caused by wear due to load accumulation over time, and that Weibull distribution was appropriate for the life distribution and acceleration was established between test conditions. From the WOLED analysis, it is thought that factors influencing the brightness deterioration are voltage, temperature, etc., and that comprehensive analysis considering discharge control, dielectric tangent margin, etc., would further increase the reliability.

건축물 마감재료 연소가스에 의한 독성평가 (A Toxicity Evaluation for the Toxic Gases of Building Finish Materials)

  • 조남욱;이동호;오은하
    • 한국응용과학기술학회지
    • /
    • 제29권1호
    • /
    • pp.129-140
    • /
    • 2012
  • 우리나라에서 건축물 내장재의 화재안전성능은 국토해양부 고시 제2011-39호에 의한 평가방법에 의해 불연성시험(KS F ISO 1182), 열방출률시험(KS F ISO 5660) 및 가스유해성시험(KSF 2271)을 실시하여 그 결과로서 분류하도록 되어 있다. 그 중 연기 및 연소독성가스에 대한 시험인 가스 유해성 시험은, 건축재료 및 내장재의 연소시 발생하는 가스의 유해성을 마우스의 평균 행동정지시간으로 측정하는 방법으로 사용하여 왔다. 이 중 연소 독성가스 4종(HCl, HF, HCN, $SO_2$) 흡입독성시험방법의 확립을 위하여 ICR계 mouse와 전신흡입노출장치를 이용하여, 독성가스 노출 및 병리검사를 수행하였다. 그 결과 호흡기관지와 가까운 폐포에서 대식세포(Macrophage)의 침윤을 유발하는 것으로 나타났고, 4종의 물질에 대한 조직의 병리검사로 전체적으로 충혈과 울혈은 확인되었다. 조직 중 폐와 신장에서 조직손상이 심하였고, 물질로는 HCN이 가장 많은 병리소견을 보였다.

영상장치 센서 데이터 QC에 관한 연구 (A study on imaging device sensor data QC)

  • 윤동민;이재영;박성식;전용한
    • Design & Manufacturing
    • /
    • 제16권4호
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

고흡수성 중합체의 자연발화와 활성화에너지 측정에 관한 연구 (A Study on Measurements of Autoignition and Activation Energy of Superabsorbent Polymers)

  • 허종만;최재욱
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.292-304
    • /
    • 2023
  • 연구목적: 일상생활의 편의를 위해 개발된 고흡수성 중합체가 생산 및 저장 사업장에서 크고 작은 발화 사고가 발생하고 있는 바, 이에 대한 화재사고 예방대책 수립을 위한 실험적인 기초자료의 확보를 위해 이 연구를 수행하였다. 연구방법: 시료용기를 가로 및 세로는 0.2m로 고정하고, 폭을 각각 3cm, 5cm, 7cm, 그리고 14cm의 크기로 직육면체 형태로 하여 무한평판에 접근하게 하였다. 미리 설정된 온도제어 프로그램에 따라 소정의 온도로 가열되게 한 항온조 중심부에 시료용기를 고정시키고 중심부의 온도가 설정하여 둔 온도보다 20℃이상 상승한 경우를 「발화」한 것으로, 시료의 중심부 온도가 설정하여 둔 온도와 유사하게 지속되었을 경우를 「비발화」한 것으로 판정하였다. 연구결과: 자연발화의 한계온도는 시료용기의 폭이 3cm일 때 212.5℃, 5cm일 때 202.5℃, 7cm일 때 192.5℃, 그리고 14cm일 때에는 177.5℃로 산출되었다. 최고의 온도에 도달되는 발화를 위한 유도시간은 3cm일 경우 약 42시간, 5cm일 경우 약 91시간, 7cm일 경우 약 151시간, 그리고 14cm일 경우 약 300시간으로 나타났다. 결론: ① 시료용기의 크기가 커질수록 자연발화온도는 낮아지고, 최고의 온도에 도달되는 발화를 위한 유도시간은 길어졌다. ② 겉보기활성화에너지는 39.30 [kcal/mol]으로 산출되었으며, 상관도는 99.5%였다.

경호행사시 초고층건물 화재 대응방안 (Action Plan of Security Service against a Fire case in a Tall Building Event)

  • 손경환
    • 시큐리티연구
    • /
    • 제39호
    • /
    • pp.37-61
    • /
    • 2014
  • 지금 전 세계는 보안이 강화된 Hard-Target(국가시설물 이나 군사시설)에 대한 테러보다는 뉴테러리즘의 등장에 의한 보안이 허술하며 접근이 용이하고 많은 민간인들이 모여 있는 Soft-Target(상업시설, 호텔, 교통시설 등)에 대한 무차별적인 테러의 공포에 휩싸여 있고, 경호대상자가 임석하는 행사는 초고층건물의 저층 혹은 고층에 위치한 장소에서 이루어지고 있는데, 이에 따른 여러 가지 위해상황에 대비한 경호적 대응방안을 준비하지만 특히 화재에 대한 대비책은 철저하게 사전 계획과 현장이 확인되어 실제 화재상황에 즉각적 대응으로 피해를 최소화할 수 있도록 완벽한 대책이 수립되어야 한다. 첫째, 경호요원은 화재와 관련된 기본적인 지식을 소유하고 있어야 하며, 바쁜 행사일정 속에서도 직무관련 교육을 주기적이고 지속적으로 시킬 수 있는 배려와 교육프로그램이 필요하다. 어느 조직이건 조직구성원의 능력은 기본적인 개인자질뿐만 아니라 조직이 지속적인 교육프로그램을 개발하고 조직구성원에게 끊임없이 교육을 실시할 수 있도록 여건을 조성해 주고 배려해 줌으로서 향상될 수가 있다. 둘째, 행사관련 여러 유관부서와의 유기적인 협조체제를 구성하고 유지하여 효율적인 지휘 통제를 실시하여야 한다. 경호행사는 어느 한 부서 혹은 기관의 노력만으로 완벽하게 이루어지는 것이 아니라는 것을 반드시 인식하여야 한다. 셋째, 초고층건물 내에서 행사가 인지되는 시점부터 대통령경호실로부터 부여받은 경호지침을 기본으로 관할 소방서에서는 화재예방활동에 중점을 두고, 화재진압대책, 피난 구조대책 등이 포함된 소방안전 대책활동 계획을 수립하고 시행하여야 한다. 넷째, 관할 소방서의 소방안전대책 활동계획을 바탕으로 하여 소방 자체의 사전 안전활동에 대한 재점검을 실시하고 화재진압 및 피난 구조계획에 대한 현장검증을 통해 실질적인 경호적 대응방안을 최종적으로 마련한다. 다섯째, 대통령경호실은 수립한 최종적인 초고층 건물 화재대비 경호행사에 동원된 모든 유관기관에 정보공유를 해야 한다. 정보공유가 되지 않은 상황에서 화재 발생시 각 유관기관들이 하나의 구심점 없이 우왕좌왕한다면 많은 혼란과 피해를 초래할 수 있기 때문이다.

  • PDF

CSMA/CA 기반 무전기를 통한 다중가입자 통신 프로토콜 (Communication protocol for multi subscribers using radio equipments based on CSMA/CA)

  • 장명진;박성진
    • 한국정보통신학회논문지
    • /
    • 제14권11호
    • /
    • pp.2385-2390
    • /
    • 2010
  • 현재 우리 군에서 많이 사용하는 PRC-999K 무전기는 반이중전송방식이며 동일망에 가입한 가입자 중 한 가입자가 데이터를 송신하면 나머지 가입자는 모두 데이터를 수신하는 브로드캐스트 빙식이다. 군 사격지휘시스템에서 무선데이터통신은 지휘소와 가입자들 사이에 1:1 유니캐스트 방식을 사용하고, 데이터 충돌을 회피하기 위해 CSMA/CA 기법을 적용하며, 효율적이고 속도가 빠른 SDLC 프로토콜을 사용한다. 본 논문은 데이터 송수신 시간 단축을 위해 각 가입자에게 순차적인 주소를 할당하고 지휘소가 데이터를 1회 브로드캐스팅 하면 지정된 가입자들 이 순차적으로 데이터 충돌을 회피해가며 응답전문을 송신하는 프로토콜과 알고리즘을 제안한다.

클라우드 서버 기반 IoT를 이용한 무선기지국 원격 감시시스템 개발 (Development of Wireless Base Station Re4mote Monitoring System Using IoT Based on Cloud Server)

  • 이양원;김철원
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 춘계학술대회
    • /
    • pp.491-494
    • /
    • 2018
  • 넓은 지역에 광범위하게 분포되어 있는 통신용 무선기지국은 관리에 많은 어려움이 있다. 특히 산간 오지에 있는 무인 통신무선 기지국은 위급한 상황 발생시에 접근에 많은 어려움을 겪고 있다. 대형 통신회사들은 송수신 정보만 원격으로 관리하고 있고 실제 시설 유지를 책임지고 있는 지역 중소기업 협력업체들은 이러한 기술을 보유하고 있지 않아서 일일이 현장 방문을 통하여 확인하고 있는 실정이다. 본 연구에서는 넓은 범위에 산재해 있는 무선기지국내의 온도, 습도, 화염 발생여부, 전원 동작 여부를 실시간으로 모니터링하여 클라우드 서버에 보내 사무실에서 실시간 모니터링을 통하여 관리 및 위급시 경고 메시지 전송 등이 수행이 가능한 시스템을 클라우스 서버 구축을 통하여 IoT 센서 기술을 이용하여 구현한 내용을 제시하고자 한다.

  • PDF

CSMA/CA 기반 반이중 전송방식 무전기를 이용한 1:N 가입자간 통신 프로토콜 (Communication protocol for 1:N subscribers using half-duplex radio equipments based on CSMA/CA)

  • 장명진;박성진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.531-534
    • /
    • 2010
  • 현재 우리 군에서 많이 사용하는 PRC-999K 무전기의 기능성은 반이중전송방식이며 동일망에 가입한 가입자 중 한 가입자가 데이터를 송신하면 나머지 가입자는 모두 데이터를 수신하는 broadcast 방식이다. 군 사격지휘시스템에서 무선데이터통신은 지휘소와 가입자들 사이에 1:1(peer to peer)방식을 사용하고, 데이터 충돌을 회피하기 위해 CSMA/CA 기법을 적용한다. 이러한 환경 하에서 데이터송수신 시간 단축을 위해서 각 가입자에게 순차적인 주소를 할당하여 지휘소가 데이터를 1회 broadcasting하면 데이터 수신이 지정된 가입자들은 순차적으로 데이터 충돌을 회피하며 응답전문을 송신하는 protocol과 알고리즘을 구현하여 제시한다.

  • PDF