• Title/Summary/Keyword: fire control time

Search Result 358, Processing Time 0.022 seconds

Full-Scale Test of Smoke-Control Performance of a Subway Tunnel (지하철 본선터널 제연성능 실물 실험)

  • Park, Won-Hee;Lee, Duck-Hee;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.94-102
    • /
    • 2011
  • Hot smoke test is done in a subway tunnel. Alcohol trays of 1.0 MW and smoke generators are used for generating hot smoke. The fans equipped with the tunnel are successively run 9 min after smoke generation. It is verified how hot smoke is controlled by fans. Velocity and direction of flow, temperature and smoke density are measured and analyzed for smoke control performance of the tunnel with fans and analyzed from the fire-safety-point of view. Velocity of smoke flow is obtained by using measured velocity and temperature at the ceiling of the tunnel. The time when smoke-control flow is builded up is different for the different positions. Velocity distributions at various positions will be used for the boundaries and the comparison data in numerical simulations for evaluation on smoke-control facilities of subway tunnel.

The Active Measure of the Operation of the Volunteer Fire Brigade in Korea (우리나라 의용소방대의 활성화 방안 고찰)

  • Jeong, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.138-142
    • /
    • 2009
  • The system of The Volunteer Fire Brigade is the Civil autonomic one which was set up from The Chosun Dynasty and has been active. Having suffered from several dificulties from Japanese control in the Chosun Dynasty, The Volunteer Fire Brigade was established by the enactment 1958 Fire Law and we have had it up to this time. The Volunteer Fire brigade played an important role in the period of the past Fire fighting personnel and equipment which we did not have. It has carried out the assistance of the Fire extinction, the early extinction of a fire in the rural region, the extinction of the forest fire, and lots of social volunteering actions etc. but, today's Fire fighting system has made the surprising developments, such as the improvement of national economic power, the increase of knowledge about the safety of the people, the openness of The Fire Fighting Department of Korea. I will try to check out the role of The Volunteer Fire Brigade which filled up the lacking part the fire fighting in the past and make the measures which can activate in these days, looking for the new field of the movement.

Smart Fire Image Recognition System using Charge-Coupled Device Camera Image (CCD 카메라 영상을 이용한 스마트 화재 영상 인식 시스템)

  • Kim, Jang-Won
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.77-82
    • /
    • 2013
  • This research suggested smart fire recognition system which trances firing location with CCD camera with wired/wire-less TCP/IP function and Pan/Tilt function, delivers information in real time to android system installed by smart mobile communication system and controls fire and disaster remotely. To embody suggested method, firstly, algorithm which applies hue saturation intensity (HSI) Transform for input video, eliminates surrounding lightness and unnecessary videos and segmentalized only firing videos was suggested. Secondly, Pan/Tilt function traces accurate location of firing for proper control of firing. Thirdly, android communication system installed by mobile function confirms firing state and controls it. To confirm the suggested method, 10 firing videos were input and experiment was conducted. As the result, all of 10 videos segmentalized firing sector and traced all of firing locations.

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Characteristics of Air Flow in the Vestibule with Multiple Fire Doors in an Apartment Building (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 공동주택 부속실내에 다수 출입문의 존재시 기류특성)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.30-36
    • /
    • 2014
  • The pressurized smoke control system in the vestibule is important for fire safety in buildings because it is concerned with egress time of people and the safety of fire fighters. The vestibule pressurization system can prevent smoke from entering the vestibule using differential pressure when fire doors are closed and using the egress velocity when fire doors are open. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule in order to assure the uniform air egress velocity through a fire door when it is open. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where multiple doors are installed and it was found that the reverse flow occurs when the damper position in vestibule is not appropriate.

A Study on improvement of plating equipment for fire prevention (도금 공장의 화재 예방을 위한 도금장비 개선에 관한 연구)

  • Kim, Sung-Jae;Kim, Sung-Gon;Yoo, Woo-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.35-42
    • /
    • 2017
  • A number of plating companies have been exposed to the risk of fire due to unexpected temperature increasing of water or other reasons in a plating bath. Since the companies are not able to forecast the unexpected temperature increasing of plating bath and most of raw materials in the bath have low ignition temperature, it is easy to be exposed to the risk of fire. Thus, in previous study, we tried to monitor and notice the dangerous change of temperature of water immediately to prevent the risk of fire from plating process. However, unfortunately previous studies were not able to shut out the fundamental cause of fire since bath temperature sensor can detect air temperature when the level sensor was malfunctioned. In this paper we developed the Teflon heater which contains a built in temperature sensor and improved plating equipment system. Teflon heater is improved using Pt $100{\Omega}$ sensor which can detect until $600^{\circ}C$. When the bath temperature sensor detects over $60^{\circ}C$ or the Teflon heater sensor detects over $240^{\circ}C$ they temporarily shut down the heater to control temperature. Also relay completely shuts down main power when detects instant temperature is detected over 5% of $240^{\circ}C$ by the heater sensor to prevent teflon melting down and fire spreads. Developed plating equipment system can monitor a real time temperature in the teflon tube and bath water. Therefore we think the proposed plating equipment can eliminate the possibility of fire in plating processes fundamentally.

A Study on Fire Protection of Chemical Plants Using FRA (Fire Risk Assessment) Method (FRA(Fire Risk Assessment)기법을 이용한 화학공장의 Fire Protection에 관한 연구)

  • Han, Seung-Hoon;Yoo, Byung-Tae;Tae, Chan-Ho;Chae, Chung Keun;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.17-26
    • /
    • 2016
  • Chemical plants and oil gas refinery facilities are intrinsically vulnerable to industrial hazards, such as explosion or fire. Especially, the fire is extremely dangerous to facility structures and plant personnel because of direct flame, radiant heat and smoke. In addition, it has the ripple effect of destroying infra-structures and polluting the environment. In an effort to tackle these potential industrial risks, the procedure of FRA techniques in chemical plants were investigated. The main focus was put on the time variation of physical properties of the main building, i.e. control rooms, warehouses and electrical substations, from a direct flame contact and radiant heat. The deformation of a building due to fire was monitored and modeled with respect to time variable. A variety of case studies, domestic and abroad, was tested in the model to verify the FRA procedure. The developed model was proven to be highly effective to reduce the possible risks at chemical plants. An accurate accident frequency prediction and damage quantification was made by the developed model.

Design and Implementation of Multi-Function Display Operational Flight Program and Middleware Using Real-Time and Embedded System Java Virtual Machine (실시간 임베디드 시스템용 자바 가상머신을 이용한 다기능 시현 비행운용 프로그램 및 미들웨어 설계 및 구현)

  • Won, Hyeon-Kwon;Jeong, Chai-Hun;Choi, Kyong-Sik;Kim, Jong-Pil;Kim, In-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.11
    • /
    • pp.1060-1068
    • /
    • 2011
  • In this paper, we present a development of an Operation Flight Program(OFP) on Real Time Operating System(RTOS) and Java Virtual Machine(JVM) of real-time and embedded system. The OFPs are consisted of Multi Function Display(MFD), Integrated Up Front Control(IUFC), Head Up Display(HUD) and Fire Control(FC) and loaded for localization Mission Computer(MC). This paper describes the structure and implementation of a MFD OFP and middleware based on Java.

A Study for the Necessity of Restructuring Korea's Emergency Management Organization - Focused on Disaster.Emergency Preparation and Civil Defence Affairs - (정부의 위기관리 조직 재설계 필요성 연구 - 재난.비상대비.민방위업무를 중심으로 -)

  • Kim, Kook-Rae
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.1-8
    • /
    • 2008
  • With a purpose to set up an efficient national security system for both at war-time and peace-time, President Lee's government transferred the emergency management function from the Office of Prime Minister to Ministry of Public Administration and Security (MOPAS). As a result national emergency management system has been changed into diversified management system ; the function of comprehensive disaster control, emergency preparation to MOPAS, fire, civil defense and disaster management to NEMA and anti-terrorism to NIS, which produce another inefficiency. For this reason, this research presents desirable improvement alternatives through scrutinizing current governmental function and structure.

Relationship between Autoigniton Temperature(AIT) and Ignition Delay Time for Acids (산(Acid)류의 자연발화온도와 방화지연시간의 관계)

  • 하동명
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.27-33
    • /
    • 2004
  • An accurate knowledge of the AIT(Autoignition temperatures) of chemicals is important in developing appropriate prevention and control measures in industrial fire protection. The AITs describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The measurement AITs are dependent upon many factors. namely initial temperature. pressure, volume, fuel/air stoichiometry. catalyst material, concentration of vapor, ignition delay time. This study measured the AITs of acids from ignition delay time by using ASTM E659-78 apparatus which was produced in the year 1994. The experiment AITs were a good agreement with the calculated AITs by the proposed equations with a few A.A.P.E.(average absolute percent error) and A.A.D.(average absolute deviation).

An Analysis of the Opening and Closing Condition with Various Fire Door Size in the Pressurized Room (부속실 출입문 크기 변화를 고려한 개방 및 폐쇄조건 분석)

  • You, Woo-Jun;Nam, Jun-Seok;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.132-137
    • /
    • 2011
  • A relationship between resisting moment and the structure of an automatic closure device is introduced for analyzing the effect of opening and closing condition on various fire door sizes in the pressurized room for smoke control system. The larger the size of fire door is, the more force is required for reaching to opening and closing conditions and there exists the design range of fire door in the pressurized room reflecting the closing time of fire door, rotative velocity, a relation between rotative angle and force and the efficiency of the automatic closure device.