• Title/Summary/Keyword: fire accident

Search Result 697, Processing Time 0.026 seconds

The Optimal Design of Explosion Prevention for LPG Storage Tank (폭발방지를 고려한 LPG 저장탱크 최적설계)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Son, Seok-Woo;Lim, Jae-Ki
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.949-952
    • /
    • 2010
  • The utilization of LPG(Liquefied Petroleum Gas) is increasing as an environmental-friendly fuel in all countries making green growth new paradigm, and use of gas is spread fast as motor fuels to decrease air pollution. Loss of lives by explosion and fire is happening every year as gas use increases, and gas accident in large scale storage property is causing serious problems socially. To minimize this problem, underground containment type storage tank is being presented as an alternative recently. In this study, to minimize explosion occurrence in underground containment type storage tank, the suitable storage tank is designed to consider explosion prevention that makes exposure surface area minimize in confined contents volume and flame to construct storage tank by the most suitable condition in the underground containment room. As a result of the design of storage tank having the most suitable condition by this research, underground containment space was minimized on diameter 3m, length 4.83m in 20 tons storage tank and its safety was improved as exposure surface area in flame decreased by 89.4%, compared with the existent storage tank.

  • PDF

Prior Research and Case Study on Overseas Assessment Models for Developing Risk Assessment Model on Domestic Customer Products (국내 소비자 제품의 위해성 평가 모델 개발을 위한 해외 평가 모델 선행조사 및 사례 비교)

  • Han, Shinho;Lee, Jongmin;Kim, Heongkee;Seo, Kum-hee
    • Journal of Applied Reliability
    • /
    • v.15 no.3
    • /
    • pp.207-215
    • /
    • 2015
  • Safety' can be used in a variety of ways and may also have different meanings when used in theoretical field and routinely used. In this paper, the 'safety' means that human injury, fire or physical accident condition does not occur while used by the end-user. The meaning of safety may be different by era and culture. Even in contemporary era, the meaning can be used differently by country, region and culture. As the rights of consumers are increasingly reinforced, we can expect the acceptable risk or safety level can rise higher. In this paper, the R-map of Japan and the European risk assessment guidelines (RAPEX) were reviewed considering domestic incidents database status and its applicability. Because it is difficult to make a model based on a R-map, a revised model was developed mainly based on European Assessment Model with a combination of the important characteristics of Japan model R-map. Also utilizing this revised model, the availability as a new risk assessment model was confirmed by comparing the test results for the same scenarios to the other risk assessment model (RAPEX/RAG).

Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault (지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구)

  • Kim, Jin-Tae;Lee, Seung-Yong;Park, Sang-Jin;Cha, Han-Ju;Kim, Soo-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

A study on the current status of prehospital emergency care for pregnant women, knowledge related to pregnant women, and self-confidence in emergency care among paramedics (119 구급대원의 임산부 응급처치 실태 및 임산부에 대한 지식과 응급처치 수행자신감에 대한 연구)

  • Park, Jong-Min;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.2
    • /
    • pp.133-153
    • /
    • 2020
  • Purpose: This study aimed to identify the status of emergency care of pregnant women transported by paramedics, to analyze the knowledge of paramedics related to pregnant women and their self-confidence in emergency care, and to provide foundational data to improve the quality of emergency care for pregnant women. Methods: We received a total of 1,798 rescue logs from 119 paramedics, who had transported pregnant women, in I city from January 1, 2016 to December 31, 2018. For survey analysis, we used the 164 questionnaires received from these paramedics from June 15 to August 14, 2019. Results: The analysis of the rescue logs revealed that 85.5% (1,537 individuals) either had disease symptoms or were pregnant, whereas only 14.5% (261 individuals) had traffic accidents or accident-related injuries. The mean knowledge of the paramedics related to pregnant women was 23.73 (±2.98) points, and the mean self-confidence in emergency care was 3.19 (±0.74) points. Knowledge of the paramedics about pregnant women and their self-confidence in emergency care of these women had a statistically significant positive correlation (r=.306, p=.000). Conclusion: Paramedics should be provided theoretical and practical training through various programs about the emergency care of pregnant women.

Analysis of Disaster for Common Utility Tunnel & Schemes of Establishing Construction criteria (공동구 재해사례와 건설기준 제정방안)

  • Yoo, Jai-Sung;Lim, Jong-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1236-1245
    • /
    • 2009
  • 공동구는 도시생활을 영위하는 데 필요한 전기, 가스, 상 하수도, 전화, 통신 등의 공공시설물을 지하매설물 형태로 설치하여 시민들의 일상생활 및 사회 경제활동의 편의성을 제공하고 안전하고 안락한 도시환경을 유지시키며, 효율적인 도시운영이 가능케 하는 공공시설물이다. 그러나, 최근 들어 여의도 공동구 화재(2000년), 여수 공동구 침수(2003년), 구리시 전력구 화재(2006)등과 같이 공동구 및 전력구에서의 화재, 혹은 침수 등에 의해 재해가 발생하여 이로 인한 국가적 경제적, 사회적 손실이 늘어가고 있다. 하지만 국내에서는 공동구내 설비를 화재 및 재해로부터 보호하기 위한 법적 장치가 미비한 실정이며, 현재 운영되고 있는 공동구의 관리 또한 시설관리공단이나 위탁관리기관 등으로 분산되어 있어 일정한 시설물 설치기준이나 유지관리제도가 정립되지 못하여 효율적인 운영이 이루어지지 않다고 판단된다. 본 연구에서는 근래 국내에서 발생한 공동구 재해사례와 공동구 관련 법규를 검토 분석하였으며, 다양화되어 가는 공동구 수용시설 조건에 부합하고 체계적이고 효율적인 공동구의 시공을 위한 공동구 건설기준 제정방안을 도출하였다.

  • PDF

High Voltage Wiring System Evaluation Methode of FCEV (Fuel Cell Electric Vehicle) (수소연료전지 자동차용 고전압 배선 시스템 평가 기술 개발)

  • Lim, Ji-Seon;Lee, Jeong-Hun;Lee, Hyo-Jeong;Na, Joo-Ran
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.330-336
    • /
    • 2012
  • FCEV uses 250 ~ 450 V instead of using 12 V battery. High voltage vehicle can cause electric shock, fire and explosion accident. Therefore, it has potential factors that can cause hazard of safety for users. United states of America and Europe legislate regulations such as ECE R100, FMVSS 305 for regulating electrical safety during driving or after collision. The company manufacturing high voltage components must do advanced R&D about Method for improving and confirming the safety of high voltage. We develop the specific hardware components of high voltage wiring system for the power train system and power supply system of Hyundai Motors FCEV. This paper shows test method of insulative performance for securing the electrical safety of high voltage components such as power cable, connectors and buss-bar, and proposals the guide line value for human safety of FCEV according to the test result of our development components.

A Study on ground fault at low voltage line and apparatus in urban railway station (도시철도역사의 저압선로 및 기기에서의 지락사고 방지 방안에 관한 검토)

  • Min Kyung-Yun;Kim Jin-Ho;Han Hag-Su
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.699-704
    • /
    • 2005
  • In the station of the railway and the subway various illumination equipment and a general power equipment for a passenger convenience, the signal equipment and the communication equipment which is necessary to the train operation provided. At the all of like this equipment from the electric room which is established in each station by changing from high voltage to low voltage and it supplies from the illumination transformer, the power transformer and the signal transformer. If it supplies to the equipment from the high voltage to the low voltage, it must be established to contact protection device in between the high voltage coil and the low voltage coil. Also it must do the grounding faulting device at the low voltage lines, the earthing devices at apparatus for the protection of an electric shock and an electric fire by the electric relation law. Compared the related regulations between the facilities which require protective functions such as grounding fault or earthing in public utilities like subway stations, and the facilities which do not require line earthing or protective functions such as electricity supplied for signalling the train. Also, will describe a countermeasure for the accident from a grounding fault.

  • PDF

A Case Study for SMRT Train Open Doors Control System (도시철도의 열차출입문제어에 관한 연구)

  • Won, Yu-Duck;Shim, Won-Sub
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.941-946
    • /
    • 2006
  • It followed in system development and SMRT(Seoul Metropolitan Rapid Transit Co)System reached to an automatic train operation(ATO) and driverless operation(DLM) from the manual operation due to the train driver. The train like the general bus or the car vehicle was not serial riding in a car and the Parallel concept which the numerous passenger rides in a car simultaneously occur frequently the charge of the train driver unmanned bitterly from existing manual handling was a possibility of doing, train open door control(ODM) which bites also ATO, it handles it minimized. Like this ATO/DLM, the control system which bites being a Wayside to Train communication for immediacy, it is a system of the Vital concept the immediacy of the citizen Data evil the radio information transmission and the train of the interface which is accurate from unmanned operation and, will decipher, will accomplish it will guarantee. It respects the passenger accident prevention and an air question environment improvement from subway platform and phul leys the screen door of Platform(PSD) with the fire tube frost it refers and part it treats and to sleep it does, ODM which bites is accuracy and immediacy of altitude and when seeing from the viewpoint which demands the trust of altitude, ODM system the trust of car incest interface in the equipment construction which is safe and the comparative analysis back of the system analysis against the control which bites and case study and other subway system it leads from the research which it sees and signal - train in base grudge to sleep it contributes it does.

  • PDF

Analysis of Electric Shock Accident on 4.16 kV Class Circuit breaker for Power Plant (발전소용 4.16 kV급 차단기에서 감전사고 사례 분석)

  • Park, Nam-Kyu;Song, Jae-Yong;Kim, Jin-Pyo;Goh, Jae-Mo
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.54-60
    • /
    • 2014
  • This paper describes electric shock accidents on a 4.16 kV class circuit breaker for power plant. Electric shock accidents mostly involve damage of human life, in comparison with electrical fire, rate of human death tend to be higher in electric shock accidents. Specially, in a high voltage facilities rate of human death comprised about 43.7% by electric shock accidents. If electric shock accidents happen in a 4.16 kV class circuit breaker for power plant, then the power plant discontinue power production. Electric shock accidents in a power plant have a great ripple effect such as an electric power shortage. In this paper, we analyzed electric shock accidents on a 4.16 kV class circuit breaker for power plant. From the analysis results, we confirmed a cause of electric shock accidents on a 4.16 kV class circuit breaker, it happened by defect of interlock equipment or occurrence of breakdown between first feeder contactor and shielding plate. In order to reduce electric shock accidents on a 4.16 kV class circuit breaker, the power plant should consider improvement of interlock equipment and insulation of feeder contactor in circuit breaker.

A Study on the Thermal Flux Estimation of Fireball (Fireball로 인한 Thermal flux 예측에 관한 연구)

  • Kim In-Tae;Kim In-Won;Song Hee-Oeul
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.46-52
    • /
    • 2000
  • In order to evaluate the risk assessment of Fireball, a program, FIRESTOR, was developed. With this program, thermal fluxes due to the fireball of propane and n-butane were predicted to analyze the damage of Puchen gas explosion accident and thermal fluxes compared with the BLEVE ESTIMATOR, and commercial program SAFER Dupont Co. Thermal fluxes with variation of distance from the explosion source by BLEVE ESTIMATOR, SAFER and FIRESTOR was made a comparative analysis each other for the constant pressure of propane and n-butane. The values calculated by FIRESTOR were between those by BLEVE ESTIMATOR and SAFER. Consequently FIRESTOR is proved to be an good program to analyze the damage of Fireball.

  • PDF