• Title/Summary/Keyword: fire accident

Search Result 703, Processing Time 0.027 seconds

A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes - (필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 -)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.48-54
    • /
    • 2016
  • Pilotis are support columns that lift a building above the ground. Thus, they can elevate the lowest floor to the secondfloor level and, in Korea, are used to leav a parking area below multifamily housing. However, if there is a fire in the piloti area, the cars and main entrance door are wrapped in flames. Due to the inflammability of the materials, the combustion of the cars and insulation at the ceiling of the pilotis, having a high heat release rate, can quickly destroy the front entrance of the building and spread heat, flames and a poisonous gas to the stairs and elevator pit. Therefore, the fire can quickly spread to the whole building, putting the lives of the residents in danger. This study was an in-depth accidental case study of the "Uijeongbu Fire Accident" that killed 5 residents and injured 139 others. The study identified the relationships between the fire at the piloti structure of multifamily housing and the vulnerability of this structure and its inherent weaknesses.

New Input Keyword Extraction of Equipments Involved in Ignition Using Morphological Analysis (형태소 분석을 이용한 발화관련 기기의 새로운 입력 키워드 추출)

  • Kim, Eun Ju;Choi, Jeung Woo;Ryu, Joung Woo
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • New types of fire accidents appear or the existing types disappeared because of rapidly changing society. We proposed a methodology of extracting new nouns from fire investigation data each of which is an accident report producted by fire investigators. The new nouns could be used in modifying the existing categories for classifying fire accidents. We analysed morphology of the product names and the ignition summaries using the proposed method for the fire accidents classified as the etc sub-category of the category of equipments involved in ignition. In this paper, we found "dryer" as a new sub-category of the agricultural equipment category and "boiler" in the seasonal appliance category from the product names of the fire accidents. We also extracted the new input keywords of "aquarium" and "monitor" in the commercial facilities category and the video, audio apparatus category from the ignition summaries respectively. Using the four subcategories, we reclassified 548 (14.39%) of 3,808 fire accidents assigned to the etc sub-category.

Thermal-Structure Interaction Parallel Fire Analysis for Steel-Concrete Composite Structures under Bridge Exposed to Fire Loading (화재에 노출된 교량하부 강합성 구조물에 대한 열-구조 연성 병렬화재해석)

  • Yun, Sung-Hwan;Gil, Heungbae;Lee, Ilkeun;Kim, Wooseok;Park, Taehyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.283-292
    • /
    • 2013
  • The objective of this research is to evaluate of global and local damage for steel-concrete composite structures under highway bridge exposed to fire loading. To enhance the accuracy and efficiency of the numerical analysis, the proposed transient nonlinear thermal structure interaction(TSI) parallel fire analysis method is implemented in ANSYS. To validate the TSI parallel fire analysis method, a comparison is made with the standard fire test results. The proposed TSI parallel fire analysis method is applied to fire damage analysis and performance evaluation for Buchen highway bridge. The result of analysis, temperature of low flange and web are exceed the critical temperature. The deflection and deformation state show good agreement with the fire accident of buchen highway bridge.

A Case of Sprinkler Non-Working by Programming Error (프로그래밍 오류에 의한 스프링클러 미작동 사례)

  • Seo, Young-Il;Cho, Young-Jin;Moon, Byung-Seon;Park, Jong-Jin;Park, Jong-Chan;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.116-120
    • /
    • 2008
  • According to the Fire Services Act revised in 2005, it has been required to set up sprinkler systems to all floors to the newly builded apartments having above 11 floors. But, according to the Fire Services Act before 2005, it had been required to set up sprinkler systems from 16 floors to the top floors to the apartments having above 16 floors. This case is the accident that a victim was dead by the fire which is inferred as an accidental fire by a cigarette butt in a 17th floor apartment unit in an apartment having 17th floors and that the bereaved family called in question why the sprinklers non worked at the fire. Through the field investigation, we checked that the sprinklers worked well when the fire detectors at the 16th floor of the apartment were operated and that the sprinklers non worked when the fire detectors at the 17th floor of the apartment were operated. We made clear that the cause of the sprinkler non-working at the 17th floor is the programming error of the sprinkler controller.

A Study on the Properties Analysis and Estimation of Odor Detection System (향 검지 시스템의 특성 해석 및 평가에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.1-5
    • /
    • 2009
  • We studies wish to investigated establishment form of cabinet board, and confirm possibility of electrical disaster prevention through reappearance experiment of odor detection system. Established breaker consists of MCCB, RCD order in cabinet board for house, but industry is used together with. When imposed shock using shaker to terminal block that contact becomes in appropriate, flame was made sure. According to result that experiment attaching odor capsule in terminal block, capsule commissioned exactly by occurred heat. According to establishment position of sensor, difference of inspection time was about 10 seconds. Estimate odor inspection system by thing which electrical device accident prevention is available. When there is abnormal generated heat in connection of electric wire, accident prevention estimates that is possible by giving an alarm state of overheat to administrator.

A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident (결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

Analysis on Chemical Accident Characteristics of Facilities Handling Hydrochloric Acid (염산 취급시설 화학사고 특성분석에 관한 연구)

  • Shin, Chang-Hyun;Lee, Hyun-Seung;Kim, Tae-Hong;Park, Jai Hak
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.14-22
    • /
    • 2016
  • This study analyzed the chemical accidents of hydrochloric acid which is the most frequent chemical in order to make safety management improvement plans. 28 Cases have occurred for the last 4 years, 8 cases of which were casualty accidents, and more efficient plans are needed to minimize the accidents. For this purpose, this study investigated the problems through yearly statistics of the chemical accidents, and suggested appropriate measures of facility management, safety culture and management plans. It is important for businesses to make and implement the improvement measures according to time schedule.

A constitution plan of national safety management system applied by systems engineering (시스템 엔지니어링을 적용한 국가 안전관리 체계 구성 방안)

  • Cho, Yun-Ok;Yoon, Hyuk-Jin;Kim, Sang-Ahm;Kwak, Sang-Log;Han, Soon-Woo
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1199-1203
    • /
    • 2007
  • As technologies are developed and systems are complicated, hazards embedded in the system are also increasing. proving safety and managing the safetyis more scientific and organizational domain so that safety management system is pursuing to be activeformation detecting the factors of hazard and managing them beyond passiveway. In the future, in order to establish and manage national safety management system, it is important to have effective system and manage it and also more important that all the people related to target system has to change their recognition and to playroles in it. Many railway safety measures reduce railway fatalities into half for last 10 years. But more improvement in railway safety is required to meet the social need after railway fire accident in Daegue. After the Daegue subway train fire accident, the Korean government has been trying to prepare a nation-wide railway safety program, a safety organization, and a Safety Act. To construct a nation-wide railway safety management program, system architecture was established.

  • PDF

Layout Optimization of FPSO Topside High Pressure Equipment Considering Fire Accidents with Wind Direction (풍향에 따른 화재영향을 고려한 FPSO 상부구조물 고압가스 모듈내부의 장비 최적배치 연구)

  • Bae, Jeong-Hoon;Jeong, Yeon-Uk;Shin, Sung-Chul;Kim, Soo-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.404-410
    • /
    • 2014
  • The purpose of this study was to find the optimal arrangement of FPSO equipment in a module while considering the economic value and fire risk. We estimated the economic value using the pipe connections and pump installation cost in an HP (high pressure) gas compression module. The equipment risks were also analyzed using fire scenarios based on historical data. To consider the wind effect during a fire accident, fuzzy modeling was applied to improve the accuracy of the analysis. The objective functions consisted of the economic value and fire risk, and the constraints were the equipment maintenance and weight balance of the module. We generated a Pareto-optimal front group using a multi-objective GA (genetic algorithm) and suggested an equipment arrangement method that included the opinions of the designer.