• Title/Summary/Keyword: fire accident

Search Result 703, Processing Time 0.027 seconds

A Study for the Management of the Wireless Communication for Safety of Firefighteer in Fire Scene (소방공무원 현장안전을 위한 무선통신망 운영에 관한 연구)

  • Son, Eun-Soo;Park, Tae-Sun;Kim, Jong-Nak;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.60-65
    • /
    • 2013
  • From an accident at 2:00 a.m. in November 2nd, 2012 that one fire-fighter died while suppressing the E land World Inc. Fire in Bupyeong-Gu, Incheon, we concluded the problem and the improvement method of using the wireless communication (the two-way radio) that the fire safety officer and the safety crew use when identifying the safety of the fire scene. And after the investigation, we could find that the communication between the fire safety officer and the safety crew was difficult in the scene of the fire by voice because of much noise, so they could rely solely on the wireless communication. Therefore, we investigated the wireless communication and its frequency now used in Incheon Fire Safety Devision. Also, we compared with those of the military and the police. As a result, by making use of the wireless communication and its frequency currently possessed in Incheon Fire Safety Division, we found that the fire safety officer and the safety crew rescuing people at the risk of their own life in the various fire scene can communicate effectively.

A Study on Ship Evacuation Safety Consequent on the Size and Sort of Fire (화재의 크기와 종류에 따른 선박 피난 안전 연구)

  • KIM, Won-Ouk;KIM, Dae-Hee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1358-1364
    • /
    • 2016
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crewmen are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. According to the ship fire survey, about 50% of the total fire accidents occurred at an engine room, and the main fire origin was analyzed to be oil. In addition, ship fire breaks out in the order of baggage racks and living quarter. In short, the survey indicates that all sorts of fires belonging to A, B, C and D-class have occurred. This study, targeting an actual passenger ship 'A', found the response time to evacuation, during which the people on board a ship recognize the outbreak of fire, and act, and the travel time for evacuation which is the actual travel time. In addition, this study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of passengers and crew based on the collected simulation data by fire size and sort. As a result of the analysis, it was found that when examining the only actual evacuation movement time excepting the response time to evacuation, people are safe by completing evacuation before the effective evacuation time only in case fire size is 100Kw among all sorts of fires. In other words, in case of the outbreak of fire more than 1 MW, it was found to fail to meet evacuation safety regardless of fire size.

A Study on the Improvement Plan of Electrostatic Safety Management Level through Injury Analysis (재해분석을 통한 정전기 안전관리 수준 향상 방안 연구)

  • Choi, Sang-won;Jeong, Seong-Choon;Park, Jae Suk;Yang, Jeong Yeol;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.37-45
    • /
    • 2019
  • The characteristic of fire and explosion related to electrostatic discharge is that it is difficult to reproduce the electrostatic charge and discharge phenomenon in addition to the large human and material damage. Therefore, in order to prevent accidents and disasters related to electrostatic in fire and explosion hazard areas, it is important to manage the level of electrostatic in a safe manner from the perspective of system between industrial facilities and human bodies. Rule 325 of the Occupational Safety and Health Regulations, "Prevention of Fire / Explosion due to Electrostatic", requires the use of grounding, conductive materials, humidification and electrification in order to prevent the risk of disaster caused by static explosion and electrostatic in the production process. In order to comply with these measures, related technologies, standards and systems are needed from the viewpoint of preventive measures related to electrostatic in fire and explosion hazard areas, but in Korea, it is still insufficient. Therefore, technical, institutional and managerial measures are needed as a precautionary measure to improve the level of ESD safety in fire and explosion hazard areas and prevent electrostatic related injury. In Korea, we analyzed the current status and characteristics of electrostatic related disaster by using the statistics of industrial accident and fire statistics of the Ministry of Employment and Labor. We also analyzed the current status and characteristics of electrostatic related disasters in Japan using JNIOSH accidents and disasters investigation cases and JNIOSH fire accident data of Japan Fire Bureau. The purpose of this study is to compare and analyze the current status of electrostatic related accidents and disasters in Korea and Japan in order to improve the safety management of electrostatic in fire and explosion hazard areas. In order to prevent accidents and disasters in the industrial field, The technical, institutional, and managerial measures to manage the level of electrostatic in a safe state were derived from the system point of view.

A Study on the Development of ICT-based Disaster Prevention Monitoring System for Shipbuilding Safety (선박 안전 건조를 위한 ICT 기반 재해방지 감시시스템 개발에 관한 연구)

  • Kim, Gi-Back;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.785-788
    • /
    • 2014
  • Even though Korea is No.1 shipbuilding country around the world, there have been a lot of accident and man-made calamity incurring in shipyards these days. Therefore most of Korea major shipyard and mid-small size shipyard deeply agonize about safety management countermeasure. As a result of it, many shipyards pour their effort on developing man watching system, PF wireless communication system, portable measuring system to prevent from accident such as fire, suffocation incurring. In this paper, analyze conventional accident & man-made calamity preventing system adopted by most of shipyard and enable the user to watch accident for 24 hours and notify it to user when it is incurring through state of the art ICT technology. And as a result of it the user can prevent the accident and man-made calamity at the beginning.

  • PDF

Investigation Study of Information Improvement in Chemical Accident by Extraordinary Chemical Reaction (이상반응 화학사고 정보제공 개선 연구)

  • Kim, Sungbum;Lim, Myunghee;Park, Joongdon
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.219-225
    • /
    • 2015
  • Hydrofluoric acid leakage accident was occurred on Dec. 2012 in Hube Global. That accident has bought many changes of response in national organizations. Chemical companies respond quickly even when small quantities leakage of chemicals and response agencies were put a lot of manpower and equipment in incident response. Incident response to the response activities of the agents is difficult if the accident substance was not identified. Unknown chemicals can be generated by the water for fire-fighting during the emergency response process. In this case, an additional information was needed for response of chemical accident to prevent of great damage. In this study, we investigated the improvement of chemical accident information by extraordinary chemical accident.

A Study on the Fire Resistance of Korean Cellulose Insulation (국내 섬유질 단열재의 내화성능에 관한 연구)

  • Kwon, Young-Cheol;Hwang, Jung-Ha;Yu, Hyung-Kyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.10-16
    • /
    • 2008
  • The fire resistance of thermal insulation and interior finishing materials is recently much emphasized after the fire accident at the Icheon Cold Store in January 2008. Three kinds of thermal insulation are used in buildings. They are Organic, Non-organic and cellulosic insulation. Organic insulation such as polystyrene foam board and urethane foam has high thermal resistance but it has no fire resistance. While non-organic insulation such as rockwool and glassfiber has high fire resistance, it has lower thermal resistance than organic insulation. Cellulose insulation is primarily manufactured from recycled newsprint or cardboard using shredders and fiberizers. Despite of its environmental friendliness and high thermal resistivity, its domestic use has not much increased because of the prejudice that paper can easily burn. However, the cellulose insulation as a product is about 80 wt.% cellulosic fiber and 20 wt.% chemicals, most of which are fire retardants such as boric acid and ammonium sulfate. It is required to secure its fire safety for more consumption as a building insulation in Korea. Therefore, this study investigates the fire resistance of Korean cellulose insulation according to the rate of fire retardant and finally presents the optimum rate of fire retardant in cellulose as building insulation. The fire safety test was conducted according to the ASTM C 1485-00. The test results indicate that above 18 wt% of fire retardant is necessary to secure the fire safety of cellulose insulation.

A Study on the Fire Risk of ESS through Fire Status and Field Investigation (화재현황 및 현장조사를 통한 ESS의 화재 위험성 연구)

  • Park, Kwang-Muk;Kim, Jae-Hyun;Park, Jin-Yeong;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.91-99
    • /
    • 2018
  • Recently, the spread of ESS in Korea has increased and a fire accident has also occurred. By July 2018, there were a total of 7 cases. All 7 cases were ESS systems consisting of lithium-ion batteries and were burned down. Both the automatic fire extinguisher and the fire department were not able to digest. In this paper, the characteristics of ESS fire are analyzed based on recent ESS fire situation and field investigation, and the cause of fire is divided into environmental, electrical and thermal factors. As a result, it was found that the ESS fire was correlated with the installation environment of the system. In the domestic and overseas lithium ion battery test standard and ESS facility standard survey, the trends and differences of domestic and overseas facilities standards were identified. Based on the fire status and field investigationy, and domestic and overseas facility standard survey, measures were suggested to prevent and prevent the spread of fire in ESS fire.

Study of the Improvement Method of a Hazardous Materials Classification System for the Introduction in GHS (GHS제도 도입에 따른 위험물 분류체계의 개선방안)

  • Lee, Bong-Woo;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.108-115
    • /
    • 2017
  • This study evaluated a preventive information communication system for the storage, handing, and transportation of hazardous materials according to the hazardous materials safety management law of Korea. At present, the chemical management system has very little information on accident responses due to a problem in the initial response. Therefore, this study was designed to improve the hazardous materials safety management law as an advanced method for simultaneous accident prevention and response, such as GHS system. This can also cause confusion in industry, such as manufacturing and import-export companies, because safety management laws and the GHS system are very different from the hazard classification systems. This study suggests a harmonization plan between the hazardous materials safety management law and the GHS classification system through an analysis of the hazardous materials classification system of major advanced countries.

Alteration of mechanical properties of tunnel structural members after a tunnel fire accident (화재 후 터널구조물 시공재료의 역학적 특성변화)

  • Chang, Soo-Ho;Choi, Soon-Wook;Kwon, Jong-Wook;Kim, Sang-Hwan;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.2
    • /
    • pp.157-169
    • /
    • 2007
  • This study aimed to quantify the deterioration of tunnel structural members such as concrete lining and shotcrete lining after a tunnel fire accident by measuring their mechanical properties between $300^{\circ}C$ and $1,000^{\circ}C$. From the experiments, it was revealed that the critical temperature where mechanical properties start to decrease linearly was approximately $300^{\circ}C$. In addition, the other critical temperature where macro-cracks are induced in specimens was around $600^{\circ}C$. From a series of regression analysis, the optimum regression function with correlation coefficients over 0.99 for mechanical properties at different temperature levels was obtained as the Boltzmann function. Finally, a schematic diagram to estimate temperature distribution inside structural members as well as their mechanical properties at corresponding temperature levels quantitatively was newly proposed for RABT and RWS fire scenarios.

  • PDF

A Study on the Improvement of Safety Management of Hazardous Chemicals Handling in the Workplace (유해화학물질 취급작업장의 안전관리 개선에 관한 연구)

  • Jeong, Gyeong-Sam;Baik, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.12-19
    • /
    • 2014
  • Workplaces handling hazardous chemicals are scattered, because of old-aging facilities are have been operating for more than 20 years, there is still has the risk of an accident. Advanced countries including the UN and strengthen regulation of chemicals, but the frequent leak accidents have become a big issue socially. In the case of subsequent domestic accidental chemical accident, the government and related departments for the overall prevention, preparedness, response system has been checked and improved. In this study, improvements of the related system and the plan of safety management for on the prevention of accidents and the initial response were suggested throughout the analysis of problems on the actual condition of safety management and such as standard of the related systems for handling, management for occurring the main cause of the leak and chemical accidents from hazardous chemicals handling in the workplace.