• Title/Summary/Keyword: finger-joint

Search Result 203, Processing Time 0.03 seconds

A Study on Design of Flexible Gripper for Unmanned FA (무인 FA를 위한 플렉시블 그리퍼 설계에 관한 연구)

  • Kim, Hyun-Gun;Kim, Gi-Bok;Kim, Tae-Kwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.3
    • /
    • pp.167-172
    • /
    • 2015
  • In this paper, we propose a new approach to design and control a smart gripper of robot system. A control method for flexible grasping a object in partially unknown environment was proposed, where a proximate sensor detecting the distance between the fingertip and object was used. Based on the proximate sensor signal the finger motion controller could plan the grasping process divided in three phases. The first step is scanning process which two first joints were moved to mid-position of the detected range by a state-variable feedback position controller, after the scanning was finished. The contact force of fingertip was then controlled using the detection sensor of the servo controller for finger joint control. The proposed grasping planning was tested on rectangular bar.

Expansion Joints for Vibration and Noise Test (신축이음장치의 진동소음 실험)

  • Kwark, Jong-Won;Kim, Young-Jin;Lee, Jung-Woo;Choi, Eun-Suk;Chin, Won-Jong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.513-516
    • /
    • 2004
  • Consistency in design, manufacture, installation and performance test of expansion joints is insufficient for guarantee of reliability because they are imported from various foreign countries as America, Japan and Europe. In addition to that, the regulations or codes of expansion joint should be revised and established for levels of vibration and noise generated from riding vehicles especially. Regulation on the noise neighboring traffic roads is established by ministry of environment. Therefore, Field tests on the vibration and the noise at expansion Joints, especially rail-type and finger-type joints which are typical ones in bridge with short or middle span, are performed and performance of expansion joints are analyzed. And so, the results of the investigation will be utilized as basic data for the regulation on the vibration and the noise.

  • PDF

Arduino-based Flex Sensor Device for Smart Healthcare (아두이노 기반의 구부림센서를 이용한 가상현실 손가락 모델링)

  • Moon, Jae-ung;Cho, Young-bok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.102-103
    • /
    • 2021
  • With the development of medical IT technology, personalized medical services are increasing in the silver industry era through the development of smart healthcare business. Therefore, in this paper, using various sensors in the Arduino environment, we implemented a finger modeling that can perform joint rehabilitation exercise that can provide personalized smart healthcare services. By measuring the activity of each individual finger joint using an Arduino-based flex sensor, it is intended to be used for personalized rehabilitation exercise in the smart healthcare field in the future.

  • PDF

A Case Study of 2 Trigger Finger Patients using Burning Acupuncture Therapy (가열식 화침(火鍼)을 이용한 방아쇠수지 치험 2례)

  • Lee, Chul-Hwi;Park, Min-Kyu;Kang, Il-A;Shin, Min-Geun;Seo, Sang-Kyung;Yoon, Gwang-Sik;Lee, Chang-Hi;Lee, Jae-Min
    • Journal of Acupuncture Research
    • /
    • v.28 no.6
    • /
    • pp.169-175
    • /
    • 2011
  • Objectives : The purpose of this case study is to observe the effect of burning acupuncture therapy on the trigger finger. Methods : 2 patients were treated by burning acupuncture therapy to recover from trigger finger. The symptoms were evaluated by visual analog scale(VAS) and Tanaka score. Results : In both cases, VAS decreased to 0 and 1. Patients were evaluated as excellent and good by Tanaka score. Conclusions : Burning acupuncture therapy is effective to trigger finger.

A Case of Isolated Collagenoma on the Finger (손가락에 발생한 고립성 교원종)

  • Yun, Young Mook;Kang, Nak Heon;Suh, Kwang Sun
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.309-311
    • /
    • 2008
  • Purpose: Collagenoma is an intradermal harmatomatous collagen proliferation among connective tissue nevi of the skin. Although there are some reports of isolated collagenomas that occurred on the sole and the palm, collagenoms at the finger has not been reported in Korea. Methods: An 11-year-old girl presented with a growing mass on the distal interphalangeal joint of the left 5th finger. It was a skin-colored, oval and mild tender mass. There were no associated cutaneous or systemic abnormal findings. Results: The nodule, at the subcutaneous level on the distal phalanx, was completely removed by excision. Grossly it was covered with normal skin, and its surface was smooth having a definite margin with a size of $1.5{\times}1.2cm$. Histopathological examination, the epidermis showed to be normal, increased thickness of collagens arranged with a whirl formation was found in the dermis. No signs of cellular component increase were observed. Conclusion: Isolated collagenoma can be aroused as a solitary nodule in at any place of the body. We report a rare case of a female patient with an isolated finger collagenoma.

A Study on Stable Grasping Control of Dual-fingers with Soft-Tips (소프트-팁이 장착된 듀얼-핑거의 안정적 파지 제어에 관한 연구)

  • 심재군;한형용;양순용;이병룡;안경관;김성수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.219-224
    • /
    • 2002
  • This paper aims to derive a mathematical model of the dynamics of handling tasks in robot finger which stable grasping and manipulates a rigid object with some dexterity. Firstly, a set of differential equation describing dynamics of the manipulators and object together with geometric constraint of tight area-contacts is formulated by Lagrange's equation. Secondly, problems of controlling both the internal force and the rotation angle of the grasped object under the constraints of area-contacts of tight area-contacts are discussed. The effect of geometric constraints of area-contacts on motion of the overall system is analyzed and a method of computer simulation for overall system of differential-algebraic equations is presented. Thirdly, simulation results are shown and the effects of geometric constraints of area-contact is discussed. Finally, it is shown that even in the simplest case of dual single D.O.F manipulators there exists a sensory feedback from sensing data of the rotational angle of the object to command inputs to joint actuators and this feedback connection from sensing to action eventually realizes secure grasping of the object, provided that the object is of rectangular shape and motion is confined to a horizontal plane.

  • PDF

Biomechanical Model of Hand to Predict Muscle Force and Joint Force (근력과 관절력 예측을 위한 손의 생체역학 모델)

  • Kim, Kyung-Soo;Kim, Yoon-Hyuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.1-6
    • /
    • 2009
  • Recently, importance of the rehabilitation of hand pathologies as well as the development of high-technology hand robot has been increased. The biomechanical model of hand is indispensable due to the difficulty of direct measurement of muscle forces and joint forces in hands. In this study, a three-dimensional biomechanical model of four fingers including three joints and ten muscles in each finger was developed and a mathematical relationship between neural commands and finger forces which represents the enslaving effect and the force deficit effect was proposed. When pressing a plate under the flexed posture, the muscle forces and the joint forces were predicted by the optimization technique. The results showed that the major activated muscles were flexion muscles (flexor digitorum profundus, radial interosseous, and ulnar interosseous). In addition, it was found that the antagonistic muscles were also activated rather than the previous models, which is more realistic phenomenon. The present model has considered the interaction among fingers, thus can be more powerful while developing a robot hand that can totally control the multiple fingers like human.

A Study on Furniture Terminology (I) -For Traditional Korean Furniture- (가구 용어 연구 I -소목 관련 용어 중심으로-)

  • Moon, Sun-Ok
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.1
    • /
    • pp.61-70
    • /
    • 2009
  • This study intended to explore English of furniture tenn in relation to the joints and moldings in traditional Korean wood furniture, a base of Korean wood furniture, for the development of Korea furniture in the future. The joints such as butt joint, rabbeted joint, mitered joint, mortise-and-tenon joint, fist joint, and finger joint, and the moldings such as a piece of thread molding, half-circle molding, cove molding, flat molding, and triangle molding were analyzed between English and Korean language. The results were only basic terms which must be researched and unified in the traditional Korean furniture. Therefore, the terms in relation to the types, the details, the hardware, and so on, will have to be studied in terms of the meaning originated from the traditional craftsmen.

  • PDF

Development of Exoskeleton-Type Data Glove for Position/Force Feedback (위치/힘 피드백이 가능한 외골격 구조의 데이터 글로브 개발)

  • Kim, Min-Jeong;Kim, Dae-Gyeong;Park, Han-Gil;Kim, Ui-Kyum;Choi, Byung-June;Choi, Hyouk-Ryeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1585-1591
    • /
    • 2011
  • In this paper, we present a new exoskeleton-type data glove that can sense the movement of the human finger and reflect the force to the finger. The data glove is designed on the basis of the skeletal structure of the human hand, and the finger module has 1 degree-of-freedom because it includes three four-bar mechanism joints in series and a wire-coupling mechanism. In addition, the transmission ratio of the finger module is maintained at 1:1.4:1 over the entire movement range, and hence, the module can perform both extension and flexion. In addition, to enable adduction/abduction motion of the human hand, a unique MCP joint is designed by using two universal joints. To validate the feasibility of the data glove, master-slave control experiments based on force-position control between the data glove and the robot hand are conducted.

Anatomical Direct Reduction of Bony Mallet Finger Using Modified-Intrafocal Pinning Technique (변형-내초점 핀 고정술을 이용한 골성 망치 수지의 해부학적 직접 정복)

  • Kang, Sang-Woo;Park, Ji-Kang;Jung, Ho-Seung;Cha, Jung-Kwon;Kim, Kook-Jong
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.248-253
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the clinical results of anatomic reduction of bony mallet finger using modified-intrafocal pinning technique. Methods: From March 2014 to October 2017, 18 patients with bony mallet finger were treated with modified-intrafocal pinning technique. Kirschner-wire was used to directly reduction the bony fragment, and extension block pinning and distal interphalangeal joint fixation were additionally performed to minimize the loss of reduction. Postoperative pain, range of motion, and radiological evaluation were performed. Duration of bone healing, functional recovery and complication rate were evaluated and Crawford's criteria was used to determine functional outcome after surgery. Results: Bone union was achieved in all cases after a postoperative mean of 6 weeks (5-7 weeks). An average of $2.8^{\circ}$ ($0^{\circ}-10^{\circ}$) extension loss occurred in all patients. All patients showed satisfactory joint congruency and reformation of the joint surface, the mean flexion angle of the distal interphalangeal joint at the final follow-up was $72.2^{\circ}$ ($70^{\circ}-75^{\circ}$). According to Crawford's classification, 12 patients (66.7%) were excellent and 6 patients (33.3%) were good. Conclusion: Modified-intrafocal pinning technique is a method of obtaining anatomical bone healing by directly reduction and fixation of the bony fragment. Combined with other conventional percutaneous pinning procedures, it is expected that good results can be obtained if applied to appropriate indications.