• 제목/요약/키워드: finger-joint

Search Result 203, Processing Time 0.035 seconds

Research of Controlled Motion of Dual Fingers with Soft-Tips Grasping (Soft-Tip을 가진 Dual Finger의 파지운동제어에 관한 연구)

  • 박경택;양순용;한현용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.670-673
    • /
    • 2000
  • This paper attempt analysis and computer simulation of dynamics of a set of dual multi-joint fingers with soft-deformable tips which are grasping. Firstly, a set of differential equation describing dynamics of the fingers and object together with geometric constraint of tight area-contacts is formulated by Euler-Lagrange's formalism. Secondly, problems of controlling both the internal force and the rotation angle of the grasped object under the constraints of area-contacts of tight area-contacts are discussed. The effect of geometric constraints of area-contacts on motion of the overall system is analyzed and a method of computer simulation for overall system of differential-algebraic equations is presented. Finally, simulation results are shown and the effects of geometric constraints of area-contact is discussed.

  • PDF

A case report on a patient with Dupuytren's contracture improved by acupuncture, moxibustion and bee venom pharmacopuncture (침, 뜸, 봉약침으로 호전된 듀피트렌 구축 환자 증례 보고)

  • Bang, Chan Hyuck;Sohn, Soo Ah;Lee, Kyung Yun;Ok, So Yoon;Choi, Yu Na
    • Journal of Acupuncture Research
    • /
    • v.33 no.2
    • /
    • pp.173-180
    • /
    • 2016
  • Objectives : To treat the progression of fibroproliferative disease that affects the flexion contracture of the fingers for patients with Dupuytren's contracture, the purpose of this study is to report a case of a patient with Dupuytren's contracture after complex Korean medical treatment. Methods : A patient was treated with acupuncture, moxibustion and bee venom pharmacopuncture on their left palmar aponeurosis. Six rounds of acupuncture and moxibustion were administered from November 30, 2015 through to January 2, 2016. Three rounds of bee venom pharmacopuncture was administered from December 14, 2015 through to January 2, 2016. The degree of flexion contracture and the Tubiana's stage were measured to evaluate the clinical improvement. Results : After 30 treatment sessions the flexion contracture degrees of the 4th finger's metacarpophalangeal joint and proximal interphalangeal joint improved as much as $25^{\circ}$, $15^{\circ}$, respectively. And the flexion contracture degrees of the 5th finger's metacarpophalangeal joint, proximal interphalangeal joint and distal interphalangeal joint improved as much as $15^{\circ}$, $10^{\circ}$, $5^{\circ}$, respectively. The Tubiana's stage of each finger decreased from 4 to 3. Conclusion : This study suggests that acupuncture, moxibustion and bee venom pharmacopuncture could be effective for patients with Dupuytren's contracture.

Tenolysis after the reconstruction of PIP joint of the finger using second toe PIP joint free flap (제 2족지 근위지관절 유리피판술을 이용한 수지 근위지관절 재건 후 시행한 건박리술)

  • Park, Hyoung Joon;Lee, Dong Chul;Kim, Jin Soo;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.450-457
    • /
    • 2009
  • Purpose: The second toe PIP joint free flap is a method of reconstruction used for abnormalities of the PIP joint of the finger. We report the results of the additional tenolysis in patients with a difference between passive ROM and active ROM after second toe PIP joint free flap. Methods: From March 2001 to July 2008, tenolysis was performed in patients with a difference in their active and passive ROM after second toe PIP joint free transfer, performed on 14 fingers. We performed a retrospective analysis of the medical records, noting the clinical and radiological findings. In addition, we measured the preoperative and postoperative range of motion of the PIP joint. Results: The average active ROM was $22.5^{\circ}$ at the three months after the joint transfer surgery, and was $38^{\circ}$ after additional tenolysis between five months and twelve months after the joint transfer. Conclusions: Additional tenolysis, after the second toe PIP joint free flap, might be a good option for improved results in patients with difference in active and passive ROM of a transferred PIP joint.

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.

Arterial or venous free flaps for volar tissue defects of the proximal interphalangeal joint: A comparison of surgical outcomes

  • Choi, Min Suk;Roh, Si Young;Koh, Sung Hoon;Kim, Jin Soo;Lee, Dong Chul;Lee, Kyung Jin;Hong, Min Ki
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.451-459
    • /
    • 2020
  • Background For volar soft tissue defects of the proximal interphalangeal (PIP) joint, free flaps are technically challenging, but have more esthetic and functional advantages than local or distant flaps. In this study, we compared the long-term surgical outcomes of arterial (hypothenar, thenar, or second toe plantar) and venous free flaps for volar defects of the PIP joint. Methods This was a single-center retrospective review of free flap coverage of volar defects between the distal interphalangeal and metacarpophalangeal joint from July 2010 to August 2019. Patients with severe crush injuries (degloving, tendon or bone defects, or comminuted/intra-articular fractures), thumb injuries, multiple-joint and finger injuries, dorsal soft tissue defects, and defects >6 cm in length were excluded from the study, as were those lost to follow-up within 6 months. Thirteen patients received arterial (hypothenar, thenar, or second toe plantar) free flaps and 12 received venous free flaps. Patients' age, follow-up period, PIP joint active range of motion (ROM), extension lag, grip-strength ratio of the injured to the uninjured hand, and Quick Disabilities of Arm, Shoulder & Hand (QuickDASH) score were compared between the groups. Results Arterial free flaps showed significantly higher PIP joint active ROM (P=0.043) and lower extension lag (P =0.035) than venous free flaps. The differences in flexion, grip strength, and QuickDASH scores were not statistically significant. Conclusions The surgical outcomes of arterial free flaps were superior to those of venous free flaps for volar defects of the PIP joint.

Precise Control Law Design of Robot Finger Embedding Distributed Actuation Mechanism (분산 구동 메커니즘을 내장한 로봇 핑거의 정밀 자세 제어기 설계)

  • Shin, Young-June;Kim, Kyung-Soo;Kim, Soo-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.9
    • /
    • pp.846-851
    • /
    • 2010
  • In this paper, we newly propose a novel control strategy of a three joints-robot finger for the purpose of artificial hands. The robot finger is specifically modeled by using a 3D CAD program (CATIA), considering human fingers, and then the proposed control method is verified through the dynamic simulation tool (Simulink and Recurdyn R2). Each slider is individually controlled to be located at the optimal positions where the maximal joint torque can be generated. To prove the effectiveness of the proposed control method, we devise two cases for the reference position of sliders. By comparing the control performance of two cases, the validity of the proposed control method will be verified.

Design and Experiment of a miniature 413-way proportional valve for a servo-pneumatic robot hand (공압구동식 로봇손을 위한 소형 4/3-Way 비례제어밸브의 설계 및 실험)

  • 류시복;김상만;홍예선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.331-336
    • /
    • 1995
  • In this past decade, industrial robot have substituted human workers successfully in certain areas, however, the applications are limited due to the shortcoming in their mechanism and control strategies. Many researchers, therefore, have focused on improving the mechanical and sensory capabilities. Developing mult-degree-of-freedom end effectors, in other words robot hands, is one of the topics that researchers have begun to improve the limitation. A set of direct drive type servo-pneumatic finger joint has been developed for a dexterous robot hand. To control the pneumatic finger joints, a prototype 4/3-way proportional control valve has been designed and tested as a preliminary, research for the control of the pneumatic finger joints. A series of experiments have been conducted to verify the performance characteristics of the valve and the conventional proportional error contral with minor-loop compensation has been used to control the anguar position of the finger joints.

  • PDF

Multisensor System Integrating Optical Tactile and F/T Sensors for Determination of Type and Position of 3D Contact Surface (3차원 접촉면의 인식 및 위치의 결정의 위한 광촉각센서와 역각센서의 다중센서시스템)

  • 한헌수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.2
    • /
    • pp.10-19
    • /
    • 1996
  • This paper presents a finger-shaped multisensor system which can measure the tyep and position of a target surface by contactl. The multi-sensor system consists of a sphere-shpaed optical tactile sensor located at the finger tip and a force/torque sensor located at the joint of a finger. The optial tactile sensor determines the type and position of the target surface using the shape and position of the CCD image of the touching area generated by a contact between the sensor and the taget surface. The force/torque sensor also determines the position and surface normal vector by applying the distributionof forces and torques t the contact point to the equations of finger shape. The measurements on the position and surface normal vector at a contact point obtined by two individual sensors are fused using a statistical method. The integrated sensor system has 0.8mm error in position measurement and 1.31$^{\circ}$ error in normal vector measurement. The developed sensor system has many applications, such as autonomous compliance control, automatic grasping and recognition, etc.

  • PDF

Research of Stable Grapsing in Field Robot (Field-Robot의 안정적 파지운동 제어에 관한 연구)

  • 박경택;심재군;한현용;양순용;이병룡
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.492-495
    • /
    • 1997
  • This paper aims to derive a mathematical model of the dynamics of handling task in field robot which stable grasping and manipulates a rigid object with some dexterity. Firstly, a set of differential equation describing dynamics of the manipulators and object together with geometric constraints of tight area-contacts on motion of the overall system is analyzed and a method of computer simulation for overall system of differential-algebraic equations is presented. Thirdly, simulation results are shown and the effects of geometric constraints of contact-area are discussed. Finally, it is shown that even in the simplest case of dual single D.O.F. manipulators there exists a sensory feedback from sensing data of he rotational angle of the object to command inputs to joint actuators and this feedback connection from sensing to action eventually realizes secure grasping of the object, provided that he object is of rectangular shape and motion is confined to a horizontal

  • PDF

Dextrous Manipulation Planning of Soft-Fingered Hands (소프트핑거 로봇손의 물체 운용계획)

  • 정낙영;최동훈;서일홍
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2016-2025
    • /
    • 1994
  • A hierarchical planning strategy for dextrous manipulation of multifingered hands with soft finger contact model is proposed. Dextrous manipulation planning can be divided into a high-level stage which specifies the position/orientation trajectories of the fingertips on the object and a low-level stage which determines the contact forces and joint trajectories for the fingers. In the low-level stage, various nonlinear optimization problems are formulated according to the contact modes and integrated into a manipulation planning algorithm to find contact forces and joint velocities at each time step. Montana's contact equations are used for the high-level planning. Quasi-static simulation results are presented and illustrated by employing a three-fingered hand manipulating a sphere to demonstrate the validity of the proposed low-level planning strategy.