• Title/Summary/Keyword: finger-joint

Search Result 203, Processing Time 0.029 seconds

A Case Report of Korean Medicine Rehabilitation Treatment after Sauve-Kapandji Procedure (Sauve-Kapandji 수술 후 한방재활치료에 대한 증례보고)

  • Cho, Eun-Byul;Geum, Ji-Hye;Baek, Dong-Gi;Lee, Jung-Han
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.14 no.1
    • /
    • pp.49-59
    • /
    • 2019
  • Objectives : The purpose of this study was to report the clinical progress of a patient exposed to a Sauve-Kapandji procedure after being diagnosed with dislocation of distal radioulnar joint and was treated using Korean medicine rehabilitation treatment. Methods : During the admission period, the patient was treated with acupuncture, cupping, herbal medicine, and Chuna therapy. The clinical progress was assessed by using range of motion(ROM), manual muscle test(MMT), numeric rating scale(NRS), and pain disability index(PDI). Results : After receiving the above treatments, the active ROM and motor grade of the elbow, wrist, and finger joints were improved; the NRS and PDI were decreased. Conclusions : Although this is a single case report, Korean medicine rehabilitation treatment, including Chuna manual therapy, might be an effective intervention for a patient after being exposed to a Sauve-Kapandji procedure.

A STUDY ON THE DIFFERENCE OF THE SKELETAL MATURITY IN NORMAL OCCLUSION AND MALOCCLUSION (정상교합자와 부정교합자의 골성숙도 차이에 관한 연구)

  • Kim, Suk Hoon;Chung, Kyu Rhim
    • The korean journal of orthodontics
    • /
    • v.20 no.1
    • /
    • pp.111-122
    • /
    • 1990
  • To investigate the relationship of skeletal maturity among the normal occlusion group and each malocclusion groups, the author used hand and wrist X-ray of 133 Korean 13 year old boys (normal occlusion 30, Class I malocclusion 35, Class II malocclusion 35 and Class III malocclusion 33) and assessed their skeletal maturity. In this study, fourteen skeletal maturity stages were selected from; Radius, Hamate, Pisiform, Ulnar sesamoid of the metacarpophalangeal joint of the first thumb, proximal phalanges of the first, second and third finger, middle and distal phalanx of the third finger. The difference of skeletal maturity of each malocclusion groups in relative to normal occlusion group and that of each malocclusion groups were analyzed. The findings of this study can be summerized as follows: 1. Average skeletal maturity stage of each groups were MP3cap stage in normal occlusion group, H-2 stage in Class I malocclusion group, midstage between S and H-2 stage in Class II malocclusion group, MP3cap stage in Class III malocclusion group. 2. There was no significant difference in skeletal maturity of Class I malocclusion and Class III malocclusion groups in relative to normal occlusion group. 3. There was significant retardation of skeletal maturity in Class II malocclusion group in relative to normal occlusion group. 4. There was no significant difference in skeletal maturity between Class I and Class II malocclusion groups. 5. There was no significant difference in skeletal maturity between Class I and Class III malocclusion groups. 6. There was significant retardation of skeletal maturity in Class II malocclusion group in relative to Class III malocclusion group.

  • PDF

Seymour's Fracture of the Base of the Distal Phalanx in a Child (소아 원위지골 기저부에서 발생한 Seymour씨 골절의 치험례)

  • Kim, Cheol Hann;Tark, Min Sung
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.776-779
    • /
    • 2006
  • Purpose: Prior to closure of the epiphysis of the distal phalanx, fracture usually occurs through the growth plate, Salter-Harris type I or II, or through the juxtaepiphyseal region 1 to 2 mm distal to the growth plate. The terminal tendon of extensor inserts into the epiphysis only, while insertion site of the flexor digitorum profundus spans both the epiphysis and metaphysis. Because of the difference between these tendon insertions, this injury mimics a mallet deformity. But, this type of injury does not involve a tear or avulsion of the extensor, unlike mallet finger of adults. Seymour was the first to describe this type of injury in children and called after his name, Seymour's fracture. This fracture is prone to infection or remain the residual deformity unless adequate treatment. Methods: We report a case of Seymour's fracture. A 9-year-old boy presented a laceration of the nail matrix, with the nail lies degloved from the nail fold on the right middle finger gotten from an impact against a door. An X-ray examination showed the fracture line lying 1 mm distal to the growth plate. The injury was treated with debridement and the fracture was reduced by applying hyperextension force. Under the C-arm, a single 0.7 mm K-wire was used to immobilize the distal interphalangeal joint. Intravenous antibiotics were applied for 5 days after surgery. Results: The K-wire was removed in the 3rd week. No infection or significant deformity was found until follow-up of 12 months. Conclusions: Seymour's fracture may be at first classically mallet deformity by its appearance. But it is anatomically different and more problematic injury. If it isn't corrected at the time of injury, derangement of the extensor mechanism, and growth deformity of the distal phalanx may occur. The fracture site should be debrided, removed of any interposed soft tissue, and the patient should be given appropriate antibiotics. Reduction should be maintained by K-wire fixation. We experienced no infection or premature epiphyseal closure.

Changes in Sensory Function After Transcranial Direct Current Stimulation on Primary Motor Cortex Area

  • Min, Dong-Ki
    • Physical Therapy Korea
    • /
    • v.21 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • Transcranial direct current stimulation (tDCS) is a neuromodulatory technique that delivers low-intensity direct current to cortical areas, thereby facilitating or inhibiting spontaneous neuronal activity. This study was designed to investigate changes in various sensory functions after tDCS. We conducted a single-center, single-blinded, randomized trial to determine the effect of a single session of tDCS with the current perception threshold (CPT) in 50 healthy volunteers. Nerve conduction studies were performed in relation to the median sensory and motor nerves on the dominant hand to discriminate peripheral nerve lesions. The subjects received anodal tDCS with 1 mA for 15 minutes under two different conditions, with 25 subjects in each groups: the conditions were as follows tDCS on the primary motor cortex (M1) and sham tDCS on M1. We recorded the parameters of the CPT a with Neurometer$^{(R)}$ at frequencies of 2000, 250, and 5 Hz in the dominant index finger to assess the tactile sense, fast pain and slow pain, respectively. In the test to measure CPT values of the M1 in the tDCS group, the values of the distal part of the distal interphalangeal joint of the second finger statistically increased in all of 2000 Hz (p=.000), 250 Hz (p=.002), and 5 Hz (p=.008). However, the values of the sham tDCS group decreased in all of 2000 Hz (p=.285), 250 Hz (p=.552), and 5 Hz (p=.062), and were not statistically significant. These results show that M1 anodal tDCS can modulate sensory perception and pain thresholds in healthy adult volunteers. The study suggests that tDCS may be a useful strategy for treating central neurogenic pain in rehabilitation medicine.

Wearable Force Sensor Using 3D-printed Mold and Liquid Metal (삼차원 프린트된 몰드와 액체 금속을 이용한 웨어러블 힘 센서 개발)

  • Kim, Kyuyoung;Choi, Jungrak;Jeong, Yongrok;Kim, Minseong;Kim, Seunghwan;Park, Inkyu
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.198-204
    • /
    • 2019
  • In this study, we propose a wearable force sensor using 3D printed mold and liquid metal. Liquid metal, such as Galinstan, is one of the promising functional materials in stretchable electronics known for its intrinsic mechanical and electronic properties. The proposed soft force sensor measures the external force by the resistance change caused by the cross-sectional area change. Fused deposition modeling-based 3D printing is a simple and cost-effective fabrication of resilient elastomers using liquid metal. Using a 3D printed microchannel mold, 3D multichannel Galinstan microchannels were fabricated with a serpentine structure for signal stability because it is important to maintain the sensitivity of the sensor even in various mechanical deformations. We performed various electro-mechanical tests for performance characterization and verified the signal stability while stretching and bending. The proposed sensor exhibited good signal stability under 100% longitudinal strain, and the resistance change ranged within 5% of the initial value. We attached the proposed sensor on the finger joint and evaluated the signal change during various finger movements and the application of external forces.

Thoracoscopic Thoracic Sympathectomy for Reflex Sympathetic Dystrophy -One Case Report - (반사성 교감신경 위축증의 흉강경하 흉추교감신경절제술 - 치험 1례 -)

  • Kim, Tae-Sik;Kim, Kwang-Taik;Kim, Hyoung-Mook;Kim, Hak-Jei;Lee, Gun
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.208-211
    • /
    • 1998
  • Reflex sympathetic dystrophy is an important clinical entity that is characterized by excessive or prolonged pain, vasomotor and other autonomic disturbances, delayed recovery of function, and trophic changes. This syndrome is among the most frequently encountered problems in clinical medicine, and proper diagnosis and therapy are critical. Accidental or surgical trauma or one of a variety of disease states may become a precipitating factor. Proper recognition and treatment result in rapid elimination of symptoms and complete recovery. A 56-years old male accidented total amputation of the proxomal part of the left index finger in May, 1996. Emergently, complete replantation procedure was successfully performed in the department of reconstructive surgery, medical center, Korea University. Afterward, he began to suffer from uncontrolled, prolonged pain in left index finger, proximally spreading pain to the left upper extremity and limited joint movement of the left shoulder. Although many treatments were used for this syndrom, not all of them were effective. Furthermore, the treatments which proved effective had detrimental side effects. However, thoracoscopic left thoracic sympathectomy was performed in our department. This therapy successfully relieved the pain and improved shoulder joint movement.

  • PDF

Usefulness of Venous Graft in Hand Injury (수부 손상에서 정맥이식의 유용성)

  • Lee, Hak-Sung;Kim, Youn-Hwan;Kim, Chang-Yeon;Kim, Jeong-Tae;Ahn, Hee-Chang
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.396-399
    • /
    • 2010
  • Purpose: In hand injury, pedicle is usually damaged by avulsion injury or crushing injury. Because of postoperative pedicle obliteration, it is often hard to save the injured hand and fingers, even after successful replantation. The author introduces three cases of extensive hand injury, and successful results after applicatoin of multiple venous grafts to these patients. Methods: In all cases there was no circulation in any finger. In the first case, some vessels were extracted, so venous graft was applied to two sites of severely damaged venous sites. In the second case, venous grafts were applied to all four digital arteries of all fingers except thumb which got severely crushed, and two sites of dorsal veins. In the third case, venous graft was applied to all four digital arteries of all five fingers, and two sites of dorsal veins and palmar veins each. Results: In all cases, survival of hands and fingers was successful. In the second case, however, amputation in thumb and little finger at DIP joint level was inevitable, because of its severe damage, and the large dorsal defect on index finger was filled with DIEP free flap. Thumb was reconstructed with toe-to-thumb free flap, and additional debulking procedures and contracture release is furtherly needed. In the first case, additional surgery was done, as FDP tendon got re-ruptured, but in long term follow-up, satisfactory range of motion was attained. In the third case, FTSG on dorsal skin region was planned. as flap on dorsal area got partial necrosis. Conclusion: In hand injury, there are many structures to be repaired, but sometimes venous graft is avoided for its long operating time. Even though the length of damaged vessel is enough for anastomosis, the endothelium is often damaged (zone of injury). In extensive hand injury, successful reconstruction would be possible with active venous graft to all vessels suspicious for damage.

Reduction Loss after Extension Block Kirschner Wire Fixation for Treatment of Bony Mallet Finger (골성 추지 신전제한 K 강선 고정술 시행 후 정복소실)

  • Kim, Byungsung;Nho, Jae-Hwi;Jung, Ki Jin;Yun, Keonhee;Park, Eunseok;Park, Sungyong
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.239-247
    • /
    • 2018
  • Purpose: We investigated occurrence of reduction loss after extension block (EB) Kirschner wire fixation or additional interfragmentary fixation (AIF) and clinical results including extension lag of the distal interphalangeal joint for treating bony mallet finger. Methods: Forty-six patients were included with a mean follow-up of 28 months (range, 12-54 months). Twenty-seven patients were treated with EB K-wire fixation (Group A) while 19 patients were treated with AIF (Group B). We checked radiologic factors, such as amount of articular involvement, volar subluxation, mallet fragment angle, reduction loss, range of motion including extension lag, and functional outcomes using Crawford's criteria. Results: Reduction loss occurred in eight patients (17%). Differences in mean extension lag, age, preoperative volar subluxation and mallet fragment angle between patients with reduction loss and those with reduction maintaining were significant. However, there were no significant differences in gender, hand dominance, amount of articular involvement, AIF, or further flexion between reduction loss and reduction maintaining. As for patterns of displacement, there was a significant relationship between gap or step-off and extension lag. Using Crawford's evaluation criteria, functional outcomes were excellent in 31, good in 10, fair in 3, and poor in 2 patients. Conclusion: Reduction loss should be careful in older age, smaller mallet fragment angle and preoperative volar subluxation.

A Study on the Design and Implementation of a Camera-Based 6DoF Tracking and Pose Estimation System (카메라 기반 6DoF 추적 및 포즈 추정 시스템의 설계 및 구현에 관한 연구)

  • Do-Yoon Jeong;Hee-Ja Jeong;Nam-Ho Kim
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.5
    • /
    • pp.53-59
    • /
    • 2024
  • This study presents the design and implementation of a camera-based 6DoF (6 Degrees of Freedom) tracking and pose estimation system. In particular, we propose a method for accurately estimating the positions and orientations of all fingers of a user utilizing a 6DoF robotic arm. The system is developed using the Python programming language, leveraging the Mediapipe and OpenCV libraries. Mediapipe is employed to extract keypoints of the fingers in real-time, allowing for precise recognition of the joint positions of each finger. OpenCV processes the image data collected from the camera to analyze the finger positions, thereby enabling pose estimation. This approach is designed to maintain high accuracy despite varying lighting conditions and changes in hand position. The proposed system's performance has been validated through experiments, evaluating the accuracy of hand gesture recognition and the control capabilities of the robotic arm. The experimental results demonstrate that the system can estimate finger positions in real-time, facilitating precise movements of the 6DoF robotic arm. This research is expected to make significant contributions to the fields of robotic control and human-robot interaction, opening up various possibilities for future applications. The findings of this study will aid in advancing robotic technology and promoting natural interactions between humans and robots.

Repercussions to the musculoskeletal system of the Upper Limb caused by scaling training exercise (치위생학과 스케일링 실습수업이 상지 근골격계에 미치는 영향)

  • Ro, Hyo-Lyun;Yoo, Ja-Hea;Lee, Min-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.3
    • /
    • pp.45-51
    • /
    • 2008
  • Purpose: We evaluated the physical stress and pain to the musculoskeletal system of a dental practitioner when engaging in a dental scaling training exercise to prevent the development of musculoskeletal injuries. Methods: The 18 female (average age: 21$\pm$1 years) subjects were voluntarily picked from a group of juniors who have completed a one-and-a-half year training course that includes training exercises on the dentiform and on live subjects (other trainees). The test is done by measuring pain, activity, grip strength, and finger dexterity for each subject's hand and wrist. Before the test all subjects were confirmed to be right-handed and were informed of the study and its objective. Measuring was done before and after each subject performed dental scaling for one hour using the scaler and the curet. Results: Pain levels increased for both hand and shoulders, but hand pain was often greater than shoulder pain. Grip strength significantly declined in the right hand but not the left. For joint mobility, the flexion and the extension for the shoulder joint did not change; but the range of motion for both wrist joints significantly increased. For the dexterity test, both hands showed increased dexterity after the exercise. Conclusion: Dental scaling can affect the shoulders and wrists/hands. Therefore, a musculoskeletal injury prevention program for dental practitioners, which may include encouraging them to assume correct body posture when at work, must be sought. This study evaluated only the shoulders, wrists, and hands; but future studies should include areas such as the cervical area, the back, and the lower limbs.

  • PDF