• Title/Summary/Keyword: fin tube

Search Result 466, Processing Time 0.028 seconds

Prevention of local overheating of a radiant tube heater (열처리용 복사튜브의 국부 과열 해소)

  • Kim H. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.119-125
    • /
    • 2004
  • Radiant tube heaters are widely used for indirect heating in heat treatment processes such as continuous annealing line(CAL) or continuous galvanizing line(CGL). Main issues for radiant tube are temperature uniformity, lifetime, thermal efficiency. To achieve higher heat release, the radiant tubes are fired at a higher fuel rate and therefore local overheating occur. A numerical simulation based on a commercial code FLUENT has been performed to investigate local overheating of radiant tube heaters. To minimize local overheating, the effects of radiating fins, flue gas recirculation(FGR), two-stage combustion were investigated. More uniform temperature distribution was achieved in the longitudinal direction within the tube with radiating fins and this contributed to increase the life of radiant tubes. Furthermore, the radiant tube with radiating fins was proven to be more efficient than the one without fins. The effects of flue gas recirculation and two stage combustion on the efficiency of the radiant tube were also considered and the results were presented.

  • PDF

The Analysis of Optimum Design Parameters for a Flat-Plate solar Collector Through Computer Simulation (컴퓨터 시물레이션 에 의한 太陽熱 集熱器 의 最適設計 에 관한 硏究)

  • 조수원;김종보
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 1984
  • In the utilization of solar energy most often a flat solar collector is used for solar heating, system. Since solar energy is absorbed through this solar collector, it is considered to be a most important part in the whole solar heating system. The purpose of the present investigation is to evaluate the influence of varying design parameters for thermal performances of flat-plate solar collector. By analysing these parameters, optimum design of solar collector would become possible. Specification of the existing solar collector are utilized in calculation as a starting point. Analysis is carried out numerically for "Unit Solar Collector" which is composed of fin and tube. Among design parameters. such parameters as mass flow rate per unit area, tube spacing and fin thickness are selected as variables in the computer simulation model. Results are presented for thermal performances of flat-plate solar collector for each important design parameters, so that predictions become possible through numerical analysis without performing experiments whenever it is required. required.

The Study of Performance Evaluation Coefficient of Fin-and-Tube Heat Exchangers with Frosting (착상을 수반한 핀-관 열교환기의 성능평가계수에 관한 연구)

  • 최봉준;황준현;신종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.132-136
    • /
    • 2003
  • For the study of performance evaluation on different shape heat exchangers that have the same energy consumption in a refrigerator, we make performance evaluation coefficient (PEC) which can distinguish performance of different shape heat exchangers. The results were reported in order to compare with for the dry frosting and wet frosting test as various definition of PECs. Results showed that PEC of dry frosting test is higher than that of wet frosting test because attached water droplet increases pressure drop of air-side then this decreases performance of heat exchanger.

An Experimental Study on the Performance Characteristics with Height of a Fin-Tube Liquid Desiccant Dehumidifier (휜-튜브형 액체건조제 제습기의 높이에 따른 성능특성에 관한 실험적 연구)

  • Lee, Su-Dong;Park, Moon-Soo;Chung, Jin-Eun;Choi, Young-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.594-603
    • /
    • 2004
  • Several desiccant cooling systems have been developed in terms of cost and performance. In this study a fin-tube exchanger has been used for liquid desiccant dehumidification system. This dehumidifier has been designed to study the absorption characteristic of the aqueous triethylene glycol(TEG) solution which has the flow range from 20 to 50 LPM. The dehumidifier performance characteristics of working factor variables such as inlet solution flow rate, air flow rate, solution concentration and brine temperature have been analyzed. This dehumidifier has the ability to provide running while saving the latent heat load of total energy. The result of this experiment can provide useful data for hybrid air conditioning system.

An Experimental Study on the Performance Characteristic with Height of a Fin-Tube Liquid Desiccant Dehumidifier (핀-튜브형 액체건조제 제습기의 높이에 따른 성능특성에 관한 실험적 연구)

  • Lee, Su-Dong;Park, Moon-Soo;Chung, Jin-Eun;Lee, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.25-30
    • /
    • 2003
  • Several desiccant cooling systems have been developed in terms of cost and performance. In this study a fin-tube exchanger has been used for liquid desiccant dehumidification system. This dehumidifier has been designed to study the absorption characteristic of the aqueous triethylene glycol(TEG) solution which has the flow range from 20 to 50 LPM. The dehumidifier performance characteristic of working factor variables such as inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity has been analyzed. The result of this experiment can provide useful data for hybrid air conditioning system.

  • PDF

Study on the Convective Heat Transfer and Pressure Drop for the Air flow Through a Plate Fin Tube Radiator of a Heat Pipe Heat Sink (평판 Fin-tube 배열을 갖는 히트파이프 히트싱크의 라디에이터를 통과하는 공기 유동에 대한 대류 열전달 및 압력 강하 연구)

  • 이수영;홍성은;강환국;김성훈;김철주
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.212-220
    • /
    • 2000
  • 히트파이프 히트싱크의 라디에이터를 통과하는 공기 유동에 대한 열전달 및 유동 압력 강하를 구하기 위한 연구를 수행하였다. 이 라디에이터는 평판 휜-관 구조이며, 평판휜에 4개의 히트파이프가 유동 방향으로 정격 배열 되어있다. 입구 공기 속도 2.5~4m/s에 대해 열전달 성능실험과 수치해석을 수행하였다. 각 히트파이프의 단위 길이당 열속이 583.3W/m, 입구 공기 속도가 3m/s일때 총합 대류 열전달계수값은 약 32W/$m^2$K, 압력 강하는 8mmAq이었다. 전체속도범위에서 실험결과와 수치 해석 결과 사이에는 약 5%의 미만의 일치를 보였다.

  • PDF

The Frost and Defrost Performances of Fin-and-Tube Exchangers with Different Surface Characteristics (표면특성이 다른 두 핀-관 열교환기의 착상 및 제상 성능)

  • 신종민;최봉준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.525-531
    • /
    • 2002
  • The effects of different surface hydrophilicity on frosting and defrosting characteristic were experimentally investigated. Mass of frost and water hold-up was measured. Results showed that no significant difference in the frost mass was found between the two different surfaces while the water hold-up of heat exchanger court be reduced by the enhancement of surface hydrophilicity. Also, the defrosting efficiency m hydrophilic surface was improved by 76%. It was expected that hydrophilic heat exchanger could provide the improvements in both thermal-hydraulic performances and system reliability during frost/defrost operating in refrigeration systems.

The Frost and Defrost Performances of Fin-and-Tube Heat Exchangers with Different Surface Treatment Characteristics (서로 다른 표면특성을 갖는 핀-관 열교환기의 착상과 제상 성능평가)

  • 최봉준;황준현;신종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.781-785
    • /
    • 2002
  • The effects of different surfaces on dry and wet frosting test were experimentally investigated. The results of experiment were compared by the performance evaluation coefficient (PEC). Results showed that the air-side pressure drop of lacquer coated evaporator increased by 5% as compared to the plasma treated one. It was also found that the Plasma coated evaporator is lower than lacquer coated one in the PEC ratio.

A Study of Correlation between DCA and WHS in Fin-and-Tube Heat Exchanger (핀-관 열교환기에서 동적접촉각과 물맺힘량과의 상관관계에 관한 연구)

  • 황준현;고영환;신종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.786-791
    • /
    • 2002
  • An experimental study on the behavior of the water hold-up by spraying of a fin-and-tube heat exchanger with regard to the surface characteristics, i.e., contact angles, was conducted. The dynamic contact angles (DCA) were measured, and water hold-up by spraying (WHS) was conducted in the experiment. It is found that heat exchanger surface characteristics, spray pressure, spray water temperature and heat exchanger surface temperature play an important role in WHS. In order to evaluate relationship between WHS and surface characteristics, test conditions are determined through a contour analysis. A correlation was proposed to predict WHS as a function of DCA. With its test efficiency and consuming time, the prediction method can be used to evaluate WHS performance.

A Study on the Characteristics of Pressure Distribution for Heat Exchanger Types of Domestic Gas Boiler (가정용 가스보일러 열교환기 유형에 따른 압력분포특성에 관한 연구)

  • 최경석;오율권;차경옥
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.22-28
    • /
    • 2001
  • Heat transfer and pressure distribution for heat exchanger type of domestic gas boiler are different from shape, pitch, thickness of fin and array of pipe respectively. In order to measure the pressure distribution across the heat exchanger, a suction type wind tunnel was constructed and velocity distribution was measured for pilot tube(4 point) of rack type. The experiments were performed for 5 different air flow mass, rpm=3,6,9,12,15 and transverse axis of heat exchanger(x-length) is 5cm respectively. Results showed that above 9.5m/s, pressure distribution dispersion for wet type of heat exchanger is on the increase and above 5.5m/s, pressure distribution dispersion for dry type of heat exchanger is on the increase. Also, pressure distribution dispersion by comparing two different types heat exchanger, dry type of heat exchanger showed a higher augmentation than wet type of heat exchanger.

  • PDF