• Title/Summary/Keyword: filter material

Search Result 747, Processing Time 0.058 seconds

Water Treatment Application of a Large Pore Micro-Filtration Membrane and Its Problems (대기공 정밀여과막의 수처리 응용 및 문제점)

  • Yun, Chang-Han;Kim, Jeong-Hak;Lee, Kang Won;Park, Sung Ho
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.194-200
    • /
    • 2014
  • The purpose of this study was to evaluate the performance of newly developed Large Pore Micro-Filtration (LPMF) membrane in Lab size for the application of water treatment, and to find its problems with solutions. The out-to-inside filtration hollow fiber LPMF membrane of which average pore size was $5{\mu}m$ was used at this study and its material was the PET braid reinforced PVDF. Filtration tests were done through gravity with 30 cm water head difference or pressure below 1.5 bar, and the backwash was done instantaneously with the filtrate after pressurizing it to about 4 bar. The water flux of the LPMF membrane with 0.2 bar TMP (Trans Membrane Pressure) was 2 times higher than $0.4{\mu}m$ MF membrane with $0.05{\mu}m$ UF filtrate of the tap water and it was measured also with 20~30 cm water head difference which showed over 800 LMH at 30 cm water head difference. And Time-To-Filter (TTF) was performed by using $5{\mu}m$ filter paper to optimize coagulants and dosage which enhanced filtrate's turbidity and stabilized filtration flux. When the LPMF was operated with 30 cm gravity with very high dose of inorganic coagulants, the flux was maintained over 80 LMH with 93.5~99.5% turbidity removal. Especially, the filtration was maintained stably in the flux and about 97% of the recovery rate by instantaneous pressurized backwash with about 4 bar of the filtrate when the packing density was about 19%. But there was instability in filtration, since the TMP was continuously going up by inefficient backwash when the packing density was 43%.

Identification of the Environmentally Problematic Input/Environmental Emissions and Selection of the Optimum End-of-pipe Treatment Technologies of the Cement Manufacturing Process (시멘트 제조공정의 환경적 취약 투입물/환경오염물 파악 및 최적종말처리 공정 선정)

  • Lee, Joo-Young;Kim, Yoon-Ha;Lee, Kun-Mo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.449-455
    • /
    • 2017
  • Process input data including material and energy, process output data including product, co-product and its environmental emissions of the reference and target processes were collected and analyzed to evaluate the process performance. Environmentally problematic input/environmental emissions of the manufacturing processes were identified using these data. Significant process inputs contributing to each of the environmental emissions were identified using multiple regression analysis between the process inputs and environmental emissions. Optimum combination of the end-of-pipe technologies for treating the environmental emissions considering economic aspects was made using the linear programming technique. The cement manufacturing processes in Korea and the EU producing same type of cement were chosen for the case study. Environmentally problematic input/environmental emissions of the domestic cement manufacturing processes include coal, dust, and $SO_x$. Multiple regression analysis among the process inputs and environmental emissions revealed that $CO_2$ emission was influenced most by coal, followed by the input raw materials and gypsum. $SO_x$ emission was influenced by coal, and dust emission by gypsum followed by raw material. Optimization of the end-of-pipe technologies treating dust showed that a combination of 100% of the electro precipitator and 2.4% of the fiber filter gives the lowest cost. The $SO_x$ case showed that a combination of 100% of the dry addition process and 25.88% of the wet scrubber gives the lowest cost. Salient feature of this research is that it proposed a method for identifying environmentally problematic input/environmental emissions of the manufacturing processes, in particular, cement manufacturing process. Another feature is that it showed a method for selecting the optimum combination of the end-of-pipe treatment technologies.

A study of Conjunctival Cellular Changes in Dry Eye Patients by Impression Cytology (Impression cytology를 이용한 건성안의 결막 세포변화에 관한 연구)

  • Kim, Jai-Min;Kho, Eun-Gyung;Chae, Soo-Chul;Kim, Soon-Ae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.333-343
    • /
    • 2004
  • Impression cytology refers to application of cellulose acetate filter material to the ocular surface to remove the superficial layers of the conjunctival epithelium. The technique is non-invasive, is easy to perform, causes minimal discomfort to the patient, and can be used to follow changes in the conjunctival ocular surface over time. With this method, the morphology of the conjunctival ocular surface can be studied and the degree of squmaous metaplasia assessed. This study was performed to evaluate the conjunctival surface by impression cytology in dry eye patients. A total of 70 students with no contact lens wearing history were recruited. Subjects were required to fill in a McMonnies dry eye symptom questionnaire. The non-invasive tear thinning time(TIT) test of each subject was measured, followed by Schirmer tear test(STI), tear film break-up time(TBUT) tests and Rose-bengal staining were performed as a baseline. Conjunctival epithelial cells from the inferior bulbar conjunctiva were harvested by the impression cytology technique. The specimens collected were labelled and stained with PAS(Periodic Acid Schift)-haematoxylin. The goblet cells and conjunctival epithelial cells were observed under a light microscope of 400x magnification. The specimens were classified according to the Nelson Grading scale which was based on the degree of squamous metaplasia such as changes of goblet cells density, size/form, N:C(nucleus : cytoplasm) ratio. Dry eye patients were observed morphological changes of the epithelial cells, different nuclear alterations, decrease of the goblet cells density. The degree of cytological changes was related to severity of dry eye conditions. When the epithelial cell morphology was graded according to the system described by Nelson, specimens from the control group revealed 91.43% of the eyes to be grade 0 and 8.57% to be grade 1, whereas of the dry eye patients, 20% were grade 0, 42.86% grade 1, 34.29% grade 2 and 2,86% grade 3. Impression cytology represents a non- or minimally invasive biopsy of the ocular surface epithelium with no side effects or contraindications. It has demonstrated to be a useful diagnostic aid for a wide variety of processes involving the ocular surface. This technique is a safe, simple method and may help increase understanding of various ocular surface alterations in dry eye patients.

  • PDF

A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3) (Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kae-Woo;Park, Jeong-Seo;Cho, Byoung-Ho;Yoo, Byeang-Jea;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.311-318
    • /
    • 2010
  • U. S. NRC Regulation Guide 1.52 regulating ESF ACS in nuclear power plants has been revised to revision 3. To apply reduction of operability test time, allowance of alternative challenge agents for in-place leak test of HEPA filters, and upgrade of Methyl Iodide penetration acceptance criterion in activated carbon performance test suggested in Reg. Guide 1.52(Rev.3) on Yonggwang units 5 and 6 ESF ACSes, technical feasibility study was carried out with on-site experiments as well as experiments with a lab-scale model. It was confirmed that the moisture in the system returned to the level before the test in 1 or 4 days even though the moisture was removed during the operability test lasting more than 10 hours. Therefore, it is appropriate to perform monthly operability test in 15 minutes just long enough to check the operability of equipment. To change challenge material for in-place HEPA filter leak test, size of aerosol, production rate, and leak detection capability were compared for DOP and PAO. It was concluded that PAO can be substituted for DOP in nuclear power plants. The upgrade of Methyl Iodide penetration acceptance criterion from 0.175 % to 0.5 % in active carbon filter bed deeper than 4 inches was to conform to the change of activated carbon performance test method to ASTM D3803(1989). It was confirmed that Methyl Iodide penetration acceptance criterion of 0.5 % under $30^{\circ}C$, relative humidity 95 % condition was conservatively good enough for testing performance of active carbon insitu. The licence change of Yonggwang units 5 and 6 has been completed based on this study.

A Survey of Staphylococcus aureus Contamination and Antibiotic Susceptibility in Retail Meat (국내유통 축산물에서의 Staphylococcus aureus 오염도 및 항생제 감수성 조사)

  • Yang, Jung-Im;Lee, Sun-Min;Lee, Gil;Lee, Hwan-Ju;Kim, Min-Kyu;Jeong, Eun-Jeong;Cha, Yong-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.4
    • /
    • pp.528-533
    • /
    • 2008
  • Staphylococcus aureus is a pathogene of major concern in livestock products. This study was conducted to test imported and domestic meat sold by retail stores for the presence S. aureus. In addition, the antibiotic susceptibility of any S. aureus found was also evaluated. The overall isolation rate of S. aureus was 20.2% (13.9% in pork and 33.8% in beef) in retail meats. The percentage of imported meats found to contain S. aureus (33.3% in pork and 40.4% in beef) was higher than that of domestic meat (13.0% in pork and 14.7% in beef). In addition, the detection rate of S. aureus was higher in raw material meat than in ready to cook packaged meat. When the antibiotic susceptibility of S. aureus isolated from the meat products was evaluated, ampicillin was found to be the highest (76.5%), followed by penicillin (75.3%), tetracycline (27.1%) and erythromycin (21.2%). Penicillin and tetracycline resistant were detected in 55.6% and 13.3% of the beef isolates, respectively, and 97.5% and 42.5% of the pork isolates, respectively. The tetracycline and erythromycin resistant plasmids of the isolated strain were transferred into S. aureus DPRMM2429 by the filter mating method and the frequencies of transfer was found to be $1.1{\times}10^{-5}{\sim}1.9{\times}10^{-9}$ and $1.2{\times}10^{-5}{\sim}4.0{\times}10^{-8}$ respectively.

A comparative study of dose distribution for whole brain with field-in-field technique (전뇌(Whole Brain)치료 시 Field-in-Field Technique 적용에 관한 고찰)

  • Kim Bo Kyoum;Lee Je Hee;Jung Chi Hoon;Pack Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 2005
  • Purpose : Uniform dose distribution of the target volume is very important in the radiation treatment. We will evaluate the usefulness of Field-in-Field Technique use to get uniform dose distribution of the target volume and try to find Apply possibility out to a whole brain treatment patient of various thickness. Material and method : We compare the dose distribution when we applied Field-in-Field Technique and parallel opposed fields technique. establish the treatment plan to a phantom(acryl 16cm spheral phantom) and do the measurement, assessment use the TLD and Low sensitivity film. Also the assessment did Apply possibility of Field-in-Field Technique to 20 patient object of various thickness. Result : In the case to use the parallel opposed fields at the whole brain treatment $10-12\%$ high dose region appeared but reduce to $3-4\%$ lesses when we used the Field-in-Field technique. We could get similar numerical value the film and TLD measurement result also. The change of the dose distribution appeared to its ${\pm}1{\sim}2\%$ although it applied such Field-in-Field technique to various patient so that we were identical. Conclusion : We can get uniform dose distribution of in the treatment region if we apply the Field-in-Field technique at the whole brain treatment. Also alternate can play the role of the wedge filter and 3D compensator and We are thought by minimizing the obstacle to be happened due to the high dose region when radiation treatment.

  • PDF

Comparison of Filtering Abilities of Korean Freshwater Bivalves and Their Filtering Effects on Water Quality (국내 담수산 조개의 섭식활동이 호수 수질에 미치는 영향)

  • Kim, Ho-Sub;Choi, Kwang-Hyun;Park, Jung-Hwan;Shin, Jae-Ki;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.2 s.98
    • /
    • pp.92-102
    • /
    • 2002
  • This study was conducted to compare filtering abilities of three species of freshwater mussels (Cobicula fluminea, Corbicula leana and Unio douglasiae) and to evaluate their filter feeding effects on water quality change in experimental enclosure systems. Mussel feeding in both laboratory and enclosure resulted in decrease of particulate material, such as chlorophyll, total P, SS. In the treatment with 600 individuals of mussels, chllorophyll concentration and net primary productivity decreased from $87.3{\pm}4.5\;{\mu}g/L$ and $106.3{\pm}8.8\;{\mu}gC\;L^{-1}\;hr^{-1}$ to nearly the same level as the mussel-free enclosure ($25.0{\pm}0.5\;{\mu}g/L$ and $15.6{\pm}13.3\;{\mu}gC\;L^{-1}\;hr^{-1}$, respectively)(P< 0.05, n = 6, ANOVA). In concert with the decrease of chlorophyll concentration, not only was the transparency enhanced from 0.48 m to 1.2m but also the suspended solids and total phosphorus decreased from $22.0{\pm}1.0\;mg/L$ to $7.5{\pm}0.5\;mg/L$ and $133{\pm}0.8\;{\mu}g/L$ to $70{\pm}0.0\;{\mu}g/L$, respectively (P<0.001, $r^2$>0.71, n = 11). Although slight decrease of SRP concentration and the increase of inorganic nitrogen ($NH_3-N$ and $NO_2-N$) were observed in the mussel addition enclosure, there was no statistical difference between two enclosures. Based on the filtering rate on phytoplankton and nutrient release rate in forms of feces and pseudofeces, Corbicula leana appeared to be the most efficient filter-feeder among three mussel species. These results inidicate that Cobicula play an important role in controlling particulate sestons and thus it could be applied as a biocontroler for the water quality management in lakes and reservoirs with algal blooms.

Pharmaco-mechanical Thrombectomy and Stent Placement in Patients with May-Thurner Syndrome and Lower Extremity Deep Venous Thrombosis (May-Thurner 증후군과 동반된 하지 심부정맥혈전환자에서 혈전제거술과 스텐트삽입술)

  • Jeon, Yonh-Sun;Kim, Yong-Sam;Cho, Jung-Soo;Yoon, Yong-Han;Baek, Wan-Ki;Kim, Kwang-Ho;Kim, Joung-Taek
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.757-762
    • /
    • 2009
  • Background: Compression of the left common iliac vein by the overriding common iliac artery is frequently combined with acute deep vein thrombosis in patients with May-Thurner Syndrome. We evaluate the results of treatment with thrombolysis and thrombectomy followed by stenting in 34 patients with May-Thurner Syndrome combined with lower extremity deep venous thrombosis. Material and Method: The authors retrospectively reviewed the records of 34 patients (mean age: $65{\pm}14$ year old) who had undergone stent insertion for acute deep vein thrombosis that was caused by May-Thurner syndrome. After thrombectomy and thrombolysis, insertion of a wall stent and balloon angioplasty were performed to relieve the compression of the left common iliac vein. Urokinase at a rate of 80,000 to 120,000 U/hour was infused into the thrombosed vein via a multi-side hole thrombolysis catheter. A retrieval inferior vena cava (IVC) filter was placed to protect against pulmonary embolism in 30 patients (88%). Oral anticoagulation with warfarin was maintained for 3 months, and follow-up Multi Detector Computerized Tomography (MDCT) angiography was done at the date of the patients' hospital discharge and at the 6 months follow-up. Result: The symptoms of deep venous thrombosis disappeared in two patients (4%), and there was clinical improvement within 48 hours in twenty eight patients (82%), but there was no improvement in four patients (8%). The MDCT angiography at discharge showed no thrombus in 9 patients (26%) and partial thrombus in 21 (62%), whereas the follow-up MDCT at $6.4{\pm}5.5$ months (32 patients) revealed no thrombus in 23 patients (72%), and partial thrombus in 9 patients (26%). Two patients (6%) had recurrence of DVT, so they underwent retreatment. Conclusion: Stent insertion with catheter-directed thrombolysis and thrombectomy is an effective treatment for May-Thurner syndrome combined with acute deep vein thrombosis in the lower extremity.

Simultaneous Determination of Ultra-Trace Pesticides and Synthetic Materials in Surface Water by LC-ESI-MS/MS (하천수에서 LC-ESI-MS/MS에 의한 극미량 농약류 및 합성원료의 동시분석법)

  • Hong, Seon-Haw;Lee, Jun-Bae;Lee, Soo-Hyung;Cho, Young-Hwan;Shin, Ho-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • A liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) was used for determining seven pesticides (2,4-dichlorophenoxyacetic acid, methomyl, aldicarb, 2-methyl- 4-chlorophenoxy- acetic acid, molinate, carbaryl and carbofuran) and two synthetic materials (quinoline and bisphenol-A) in surface water. The analytes were extracted using solid-phase extraction (SPE). The eluate was concentrated by nitrogen gas. 100 microliters of 30% (v/v) methanol aqueous solution were used to dissolve the residue and an aliquot of the reconstituted solution was directly injected into LC-ESI-MS/MS after the filtration using 0.2 μm polytetrafluoroethylene (PTFE) syringe filter. Under the established condition, the calibration curves of the analytes were linear with correlation coefficients of above 0.997. The quantification limit was 0.002~0.011 μg/L and the relative standard deviations were less than 16.4%. In addition, accuracy was in the range of 84~107% and the recoveries were values between 56.2 and 98.6%. In this study, the developed method was applied to the analysis of real surface water samples.

General Steady-State Shape Factors in Analyzing Slug Test Results to Evaluate In-situ Hydraulic Conductivity of Vertical Cutoff Wall (순간변위시험(slug test)시 연직차수벽의 현장투수계수를 산정하기 위한 형상계수 연구)

  • Lim, Jee-Hee;Lee, Dong-Seop;Nguyen, Thebao;Choi, Hang-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.10
    • /
    • pp.105-116
    • /
    • 2011
  • No analytical solution exists for evaluating in-situ hydraulic conductivity of vertical cutoff walls by analyzing slug test results. Recently, an analytical solution to interpret slug tests has been proposed for a partially penetrated well in an aquifer. However, this analytical solution cannot be directly applied to the cutoff wall because the solution has been developed exclusively for an infinite aquifer instead of a narrow cutoff wall. To consider the cutoff wall boundary conditions, the analytical solution has been modified in this study to take into account the narrow boundaries by introducing the imaginary well theory. Two boundary conditions are considered according to the existence of filter cakes: constant head boundary and no flux boundary. Generalized steady-state shape factors are presented for each geometric condition, which can be used for evaluating the in-situ hydraulic conductivity of cutoff walls. The constant head boundary condition provides higher shape factors and no flux boundary condition provides lower shape factors than the infinite aquifer, which enables to adjust the in-situ hydraulic conductivity of the cutoff wall. The hydraulic conductivities calculated from the analytical solution in this paper give about 1.2~1.7 times higher than those from the Bouwer and Rice method, one of the semi-empirical formulas. Considering the compressibility of the backfill material, the analytical solution developed in this study was proved to correspond to the case of incompressible backfill materials.