• Title/Summary/Keyword: filling property

Search Result 125, Processing Time 0.025 seconds

Improvement of Physical Property of Autoclaved Light-Weight Concrete Using Admixtures and Chemical Reactants (혼화재 및 화학반응제를 혼입한 경량기포콘크리트의 물성 개선)

  • Song, Hun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.4
    • /
    • pp.87-95
    • /
    • 2012
  • Autoclaved lightweight concrete (ALC), also known as autoclaved aerated concrete (AAC), is a lightweight, precast building material that simultaneously provides structure, insulation. ALC is a unique building material. Because of its cellular nature, it is lightweight, self-insulating, as well as sound and fireproof. ALC products include blocks, wall panels, floor and roof panels, and lintels. Recently, the use of ALC has became increasingly popular. However, ALC have high water absorption, low compressive strength and popout the origin of the low surface strength in its properties. Thus, this study is to improve the fundamental strength by controls of increasing of admixtures and chemical reactants. Admixtures make use of meta kaolin and silica fume, chemical reactants make use of sodium silicate and sodium hydroxide. From the test result, the ALC using admixtures and chemical reactants have a good fundamental properties compared with plain ALC. These good fundamental properties is caused by the admixtures and chemical reactants of ALC by the reason of the micro filling effect and chemical binding of C-S-H gel, tobermolite and quartz.

Microstructure and Mechanical Properties of 3vol%CNT Reinforced Cu Matrix Composite Fabricated by a Powder in Sheath Rolling Method (분말시스압연법에 의해 제조된 3vol%CNT 강화 Cu기 복합재료의 미세조직 및 기계적 성질)

  • Lee, Seong-Hee
    • Korean Journal of Materials Research
    • /
    • v.30 no.3
    • /
    • pp.149-154
    • /
    • 2020
  • A powder-in-sheath rolling method is applied to the fabrication of a carbon nano tube (CNT) reinforced copper composite. A copper tube with outer diameter of 30 mm and wall thickness of 2 mm is used as sheath material. A mixture of pure copper powder and CNTs with a volume content of 3 % is filled in a tube by tap filling and then processed to an 93.3 % reduction using multi-pass rolling after heating for 0.5 h at 400 ℃. The specimen is then sintered for 1h at 500 ℃. The relative density of the 3 vol%CNT/Cu composite fabricated using powder in sheath rolling is 98 %, while that of the Cu powder compact is 99 %. The microstructure is somewhat heterogeneous in width direction in the composite, but is relatively homogeneous in the Cu powder compact. The hardness distribution is also ununiform in the width direction for the composite. The average hardness of the composites is higher by 8Hv than that of Cu powder compact. The tensile strength of the composite is 280 MPa, which is 20 MPa higher than that of the Cu powder compact. It is concluded that the powder in sheath rolling method is an effective process for fabrication of sound CNT reinforced Cu matrix composites.

Synthesis and Characterization of Zeolite Composite Membranes (I):Synthesis of ZSM-5 Type Zeolites (제올라이트 복합 분리막의 합성 및 특성화(I): ZSM-5계 제올라이트의 합성)

  • 현상훈;김준학;송재권
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.9
    • /
    • pp.1064-1072
    • /
    • 1996
  • The synthetic conditions and characteristics of ZSM-5 type zeolites (ZSM-5/silicalite) for the preparation of the zeolite composite membranes for gas separation were investigated. ZSM-5 zeolites could be synthesized by the hydrothermal treatment of the mixture of colloidal silica sol aluminum nitrate sodium hydroxide and TPABr at a temperature range of 150-17$0^{\circ}C$ in the autoclave. Silicalties were done from the solution of water glass water and TPABr. Their crystalline structures transformed from orthorhombic to monoclinic from and their pore structures of three-dimensional channels were opened as TPABr filling channels was burned off at the calcination temperature of 50$0^{\circ}C$. The specific surface area of the calcined zeolite was about 360 m3/g and its surface property was hydrophobic. Crystal sizes of ZSM-5 and silicalite were 0.5-1.0${\mu}{\textrm}{m}$ and 8-10${\mu}{\textrm}{m}$ respectively having no change due to the calcination. In particular the shape and the size of the ZSM-5 type zeolite were sensitively varied with silica sources and concentrations of reaction solutions/sols.

  • PDF

A Study on the Optimal Installation Technology of LPG Storage Tank through Taguchi Method (다구찌 기법을 통한 LPG 저장탱크시공방법의 최적화에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Paek, Seung-Cheol;Lee, Jong-Rark
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.98-102
    • /
    • 2010
  • LPG (Liquefied Petroleum Gas) vehicles in metropolitan area are being applied to improve air quality and have been proven effective for the reduction of air pollutant. In addition, the demand of gas as an eco-friendly energy source has being increased. With the LPG filling station is also increasing every year. These gas stations are required to install the securest storage tank because of possibility of causing huge loss of life and property. Therefore, in this paper, underground containment type is proposed as installation of the LPG storage tank using Taguchi method, which is considered to be more safe, economical, efficient, easy checking and simple construction method than any other. If leakage, economics, real estate utilization rate, safety, easy to check, simple construct about above ground, buried underground and underground containment storage tank are analyzed by Taguchi method, real estate utilization rate, economic and safety in turn are improved. Therefore, the underground containment storage tank is a optimal installation technology.

The self-compacting property of concrete as to specific gravity and mixing proportion of lightweight coarse aggregate (경량 굵은골재 비중 및 혼합률에 따른 콘크리트의 자기충전성)

  • Choi, Yun-Wang;Kim, Yong-Jic;Choi, Wook;Lee, Sang-Ho;Cho, Sun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.747-750
    • /
    • 2004
  • Lightweight concrete is known for its advantage of reducing the self-weight of the structures, reducing the areas of sectional members as well as making the construction convenient. Thus the construction cost can be saved when applied. to . structures such as long-span bridge and high rise buildings. However, the lightweight concrete requires specific design mix method that is quite different from the typical concrete, since using the typical mix method would give rise the material segregation as well as lower the strength by the reduced weight of the aggregate. In order to avoid such problems, it is recommended to apply the design mix method of high performance self-compacting concrete for the lightweight concrete. Therefore, this study introduces a production of self-compacting concrete, PF-modified and improved version of Nan-Su's design mix method of self-compacting concrete. Through a series of test mixes conducted during the study, the quality of the concrete at its fresh condition has been evaluated per the 2nd class rating standards of self-compacting concrete published by JSCE, especially focused in its fluidity, segregation resistance ability, and filling ability.

  • PDF

Hydro-mechanical coupling algorithm of reinforced concrete lining in hydraulic pressure tunnel using cohesive elements

  • Li Zhou;Kai Su;Ding-wei Liu;Yin-quan Li;Hong-ze Zhu
    • Structural Engineering and Mechanics
    • /
    • v.86 no.1
    • /
    • pp.139-156
    • /
    • 2023
  • The reinforced concrete lining in the hydraulic pressure tunnel tends to crack during the water-filling process. The lining will be detached from the surrounding rock due to the inner water exosmosis along concrete cracks. From the previous research achievements, the cohesive element is widely adopted to simulate the concrete crack but rarely adopted to simulate the lining-rock interface. In this study, the zero-thickness cohesive element with hydro-mechanical coupling property is not only employed to simulate the traditional concrete crack, but also innovatively introduced to simulate the lining-rock interface. Combined with the indirect-coupled method, the hydro-mechanical coupling algorithm of the reinforced concrete lining in hydraulic pressure tunnels is proposed and implemented in the finite element code ABAQUS. The calculated results reveal the cracking mechanism of the reinforced concrete lining, and match well with the observed engineering phenomenon.

Characterization of Surface Deterioration for Stone Property around the Hyeonleung (Royal Tomb of Joseon Dynasty) in Guri, Korea (구리 현릉 능상석물의 표면 손상특성 평가)

  • Oh, Jeong Hyun;Kim, Sa Dug;Lee, Chan Hee;Lee, Tae Jong
    • Journal of Conservation Science
    • /
    • v.32 no.3
    • /
    • pp.353-364
    • /
    • 2016
  • The materials of sculptured stone property around the Hyeonleung Royal Tomb in Guri consist mainly of high weathered of granitic rocks with magnetite-series. Deterioration characteristics occurred highly with microorganism, soil inflow and black contaminants at the burial mound zone. As a result of deterioration evaluation, stone surface around the burial mound zone show serious comprehensive damage of soil inflow (50.5%) and lichen coverage (47.6%) which are the major damaging factors, and there are about 8.6% of biological growth noticeably in the north side. Surface contaminants and the discoloration had the complex causes. Gypsum occurred between joints of stones and the major contaminant type, darkening which was analyzed organic bodies caused discoloration. From result of ultrasonic velocity measurements, there are mean value of 2,195 m/s with highly weathered (HW) grade. Most of the stone properties showed 4 to 5 weathered grade. Therefore, it turned out that sculpture stone properties require conservation treatments. To remove soil accelerating damage factors and lichen occupying high percents, the cleaning process is necessary and consolidation, rejoining and filling are needed as well. Also, consideration on removing conservation materials containing Ca and e fflorescence is required and retreatments need to be considered.

Property Changes of Anion Exchange Pore-filling Membranes According to Porous Substrates (지지체 종류에 따른 음이온 교환 함침막 특성 변화)

  • Jeon, Sang Hwan;Choi, Seon Hye;Lee, Byeol-Nim;Son, Tae Yang;Nam, Sang Yong;Moon, Sun Ju;Park, Sang Hyun;Kim, Ji Hoon;Lee, Young Moo;Park, Chi Hoon
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.344-349
    • /
    • 2017
  • Alkaline fuel cells using polymer electrolyte membranes are expected to replace proton exchange membrane fuel cells, which have similar system configurations. In particular, in alkaline fuel cells, a low-cost non-platinium catalyst can be used. In this study, to fabricate high performance and high durability anion exchange membranes for alkaline fuel cell systems, two kinds of supports, polybenzoxazole and polyethylene supports, were impregnated with Fumion FAA ionomer, by which we tried to fabricate the support-impregnated membrane which has higher mechanical strength and higher ion conductivity than the Fumion series. Finally, the Pore-filling membranes were successfully fabricated and ionic conductivity and mechanical properties were different depending on the properties of the supports. In the pore-filling membranes with Fumion ionomer on the PE support, excellent mechanical properties were obtained, but ionic conductivity decreased. On the other hand, when the PBO support was impregnated with Fumion ionomer, high ionic conductivity was shown after impregnation due to high basicity of PBO, but the mechanical strength was relatively low as compared with Fumion-PE membrane. As a result, it was concluded that it is necessary to consider the characteristics of the support according to the operating conditions of the alkaline fuel cell during the preparation of the pore-filling membranes.

A New Method for Enhancement of Right-Left Pump Output Balance in the Totally Implantable Artificial Heart (완전이식형 인공심장의 좌,우 심박출량 균형의 개선에 관한 연구)

  • Choe, Won-U;Kim, Hui-Chan;Kim, Won-Gon;No, Jun-Ryang;Kim, In-Yeong;Min, Byeong-Gu
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.385-391
    • /
    • 1998
  • A new balancing method of atrial pressures balancing for the moving actuator total artificial heart(TAH) without an extra compliance chamber was developed. The asymmetric operation of the pendulous moving actuator have made it possible to compensate the left and right pump output difference by utilizing the interventricular air space as an internal compliance chamber in a pump housing. Furthermore, the balancing performance between left and right pump outputs is increased through the improvement of the flexibility of part of the polyurethane housing. However, the increase of the flexibility of the pump housing causes a little loss of the cardiac output due to the reduction of active filling property. In this paper., a good condition between the balance and pump output performance is evaluated by adjusting the air volume in the interventricular space through a series of in vitro experiments. This new pump was implanted in a sheep weighting 63kg, and it survived for 3 days and the average cardiac output during postoperative days was about 4.2 L/mim with the atrial pressures under 15 mmHg.

  • PDF

CHEMICAL INVESTIGATION ON THE REACTION BETWEEN CALCIUM HYDROXIDE INTRACANAL MEDICAMENT AND ZINC OXIDE-EUGENOL (수산화칼슘 근관약제와 산화아연-유지놀의 반응에 관한 화학적 분석)

  • Park, Sook-Hyung;Park, Joon-Chol;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.272-288
    • /
    • 2000
  • Calcium hydroxide is used as a root canal medicament with its several pharmacological effects. However, it has been known that the usage of calcium hydroxide in the root canal system before canal filling with gutta-percha and zinc oxide eugenol-based cement induced change in the properties of root canal cement which might adversely affect sealing ability of the canal filling. The purpose of this study was to identify the reactivity of calcium hydroxide-eugenol compound made from chemical interaction of between calcium hydroxide and zinc oxide eugenol. Chemical properties of calcium hydroxide, eugenol, zinc oxide eugenol, calcium hydroxide-eugenol and calcium hydroxide-zinc oxide eugenol compound were analyzed using XRD. FT-IR Spectrophotometer and FT-NMR Spectrometer. The results were as follows: 1. The compound made from interaction between calcium hydroxide and zinc oxide eugenol was as follows : 2. Calcium hydroxide was shown to make chemical bond (ionic bond) with eugenol. 3. Since bonding between $Ca^{2+}$ and eugenol is simple ionic nature, under water existence, calcium hydroxide-eugenol compound may be ionized easily and its physical property be deteriorated.

  • PDF