• Title/Summary/Keyword: filling imbalance

Search Result 53, Processing Time 0.021 seconds

Injection Molding 3D CAE Applications for Estimating Filling Imbalance Using a New Runner system meshing (새로운 3D 멧싱 기법으로 충전 불균형을 예측할수 있는 사출성형 CAE 활용)

  • Go, Seung-Woo;Jung, Su-Jung;Seo, Sang-Hun;Jeong, Yeong-Deug
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.121-127
    • /
    • 2008
  • Nowdays CAE has been used for almost all injection molding designs in order to find the best injection conditions. Almost all CAE use 2-D mesh, but the CAE with 2-D mesh can't indicate such as jetting, flow-mark and filling imbalance in multi cavity mold. In this study, we suggested a new 3D meshing. the method which can indicate the filling imbalance in geometrically balanced runner system with Mold Flow MPI 6.1 and we found out that the calculation times are saved. As a feasibility study, we verified that Melt Flipper, RC Pin etc appeared the balanced filling behaviors. of geometrically balanced runner system and Melt Flipper, filling imbalance was indicated more accurately.

  • PDF

The Filling Imbalance in Multi-Cavity Injection Molds with Unary Branch Type Runner Lay-out (편측 분기형 러너 배열을 가진 다수 캐비티 사출금형에서의 충전 불균형도)

  • 강철민;정영득
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.72-75
    • /
    • 2003
  • Almost all injection molds have multi-cavity runner system for productivity and are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, filling imbalances have been observed though geometrically balanced runner lay-out are used. Generally, these filling imbalances are due to thermal unbalance, viscosity, characteristic of polymers and so on. These kinds of filling imbalances has already been reported by Beaumont[1] since 1997. In this study, we presented filling imbalaces in balanced runner that has unnary branch type lay-out through experimental tests. As a result of experiments, we could present the processing conditions for the balanced filling in geometrically balanced runner that has unnary branch type lay-out

  • PDF

Development of Runner System for Filling Balance in Multi Cavity Injection Mold (다수 캐비티 사출금형에서 균형 충전용 러너 시스템 개발)

  • Jeong Y. D.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.09a
    • /
    • pp.13-16
    • /
    • 2005
  • For mass production, usually injection mold has multi-cavity which is filled through geometrical balanced runner system. Despite geometrical balanced runner system, filling imbalances between cavity to cavity have always been observed. These filing imbalances are one of the most significant factors to affect quality of plastic parts when molding plastic parts in multi-cavity injection mold. Filling imbalances are results from non-symmetrical shear rate distribution within melt as it flows through the runner system. It has been possible to decrease filling imbalance by optimizing processing conditions, but it has not completely eliminated this phenomenon during injection molding processing. This paper presents a solution of these filling imbalances through using 'runner core pin'. The runner core pin which is developed in this study creates a symmetrical shear distribution within runner. As a result of using runner core pin, a remarkable improvement in reducing filling imbalance was confirmed.

  • PDF

A Closed-loop-control System for Filling Balance in the Hot Runner Mold with Multi-Cavities (다수 캐비티를 갖는 핫러너 금형에서의 균형충전을 위한 자동제어시스템)

  • Jang, Min-Kyu;Jo, Il-Kyu;Lee, Ok-Seong;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.23-26
    • /
    • 2015
  • For mass production of plastics, injection molds have multi-cavities. However, filling imbalance between cavity to cavity always has occurred in multi-cavities mold, and this has caused low quality of plastics part. In this study, the closed-loop-control system which can control temperature of hot manifold and nozzle in hot runner mold for filling balance has been suggested, and a series of experiment about difference of filling time and weight in cavity-to-cavity was conducted. As a result of using closed-loop-control system, a remarkable improvement in reducing filling imbalance was confirmed.

  • PDF

Degree of Filling Balance according to Runner Shapes in Injection Mold (사출금형의 러너시스템 형상에 따른 균형 충전도)

  • Han, Dong-Yeop;Jeong, Yeong-Deug
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.144-149
    • /
    • 2008
  • Configuration of filling imbalance which is originated from imbalanced share rate of melt on runner is changed by runner layout, runner shape, material property, injection pressure, injection speed, melt temperature and mold temperature. In this paper, we conducted a study of runner layout and shape that are main factors of filling imbalance. Other factors such as the sharp corner effect and the groove corner effect are recently released were also considered. The results of study are showed that filling rate of between inside and outside cavity was influenced on shape of runner. Especially, this study suggests a new runner system for filling balance by adapting the two effects of unary branch type runner at multi cavity mold and theoretical investigated flow in the sharp corner type runner.

The Filling Balance of LDPE/ABS/PA6,6 Resin in Variable-Runner-System (가변러너시스템에서 LDPE/ABS/PA6,6 수지의 충전균형)

  • Park, H.P.;Cha, B.S.;Kang, J.K.;Rhee, B.O.
    • Transactions of Materials Processing
    • /
    • v.15 no.9 s.90
    • /
    • pp.641-647
    • /
    • 2006
  • During the injection molding process an excessive packing can occur in the smaller volume cavity because of volumetric difference of the family-mold. It causes warpage by increased residual stress in the product and flesh by over packing. In this study, we used a variable-runner system for the filling balance of the cavities by changing the cross-sectional area of a runner, and confirmed the filling imbalance by temperature and pressure sensors. We carried out experiments to examine the influence of types of resins such as LDPE/ABS/PA6,6 on the filling balancing of the system, in order to help mold designers, who can easily adopt the variable-runner system to their design. We also examined filling imbalance in the system with CAE analysis.

A Study on the Filling Imbalance of Polyamide Molding by Taguchi Method (다구찌 방법을 이용한 폴리아미드 성형품의 충전 불균형에 관한 연구)

  • Han, Kyu-Taek;Jeong, Yeong-Deug;Goo, Yang;Kim, Byung-Tak;Kim, Hyung-Je;Han, Seong-Ryul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.4
    • /
    • pp.95-100
    • /
    • 2004
  • Plastics is used to produce precise parts with an inclusion of a reinforcement material such as glass fiber or carbon fiber to improve the dimension accuracy. The plastic goods can be produced with inaccurate dimensions, low mechanical strength, or residual stress due to the over packing of cavity inside, if the filling balance of melt resin is not accomplished. To overcome this problem, it is necessary to design the runner system with the geometrical balance at the mold design stage. However, even if the balanced runner system is achieved, a severe filling imbalance is observed practically in a multi-cavity mold. In this study, experiments were performed with Taguchi method to achieve the filling balance in multi-cavity mold with a symmetric runner system, by the use of pure PA and PA with glass fiber 33%. The experimental results were investigated to understand the effect of related molding factors on the filling imbalance for two resins.

  • PDF

Runner Design for Filling Balance in Multi-cavity Injection Mold (다수 캐비티 사출금형에서 충전 균형을 위한 런너의 설계)

  • Kang, M.A.;Lyu, M.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.329-332
    • /
    • 2008
  • Flow imbalance among the cavities was often observed in multi-cavity mold. The flow imbalance affects on the dimensions and physical properties of melded articles. First of all, the origin of flow imbalance is geometrical imbalance of delivery system. However, even the geometry of delivery system is balanced the cavity imbalance is being developed. This comes from the temperature distribution in the cross-section of runner, which is affected by the operational conditions. In this study, experimental study of flow imbalance has been conducted for various injection speeds. This study also suggests new runner design to eliminate flow imbalance in multi-cavity injection mold. Simulation and experimental results showed suggested new designed runner could eliminate or reduce flow imbalance in multi-cavity injection mold.

  • PDF

Verification of gate balancing equation using injection molding analysis (사출성형해석 연구를 이용한 게이트 밸런스 계산식의 검증)

  • Han, Seong-Ryeol
    • Design & Manufacturing
    • /
    • v.12 no.3
    • /
    • pp.55-59
    • /
    • 2018
  • In a multi-cavity mold having a runner layout of a fish bone structure, problems of unbalanced filling between cavities occur constantly. Unbalanced charging lowers the dimensional accuracy of a molded article and causes deformation after molding. To solve this problem, the gate size connected to each cavity is adjusted using the BGV (Balanced Gate Value) equation. In this paper, in order to solve the filling imbalance problem of the runner layout mold of fish bone structure through injection molding analysis study, we compared the charging imbalance phenomenon before and after improvement after adjusting the gate size by applying BGV equation. From the results of the molding analysis, the shrinkage ratio before and after the improvement of the molded article was improved by only about 0.08%. Based on these results, it was confirmed that the charging imbalance problem was not significantly improved even when the BGV equation was applied.

Development of New Runner System for Filling Balance in Multi Cavity Injection Mold (다수 캐비티 사출금형에 적용되는 새로운 균형 충전용 러너 시스템 개발)

  • Jeong Y. D.
    • Transactions of Materials Processing
    • /
    • v.15 no.1 s.82
    • /
    • pp.42-46
    • /
    • 2006
  • For mass production, usually injection mold has multi-cavity which is filled through geometrical balanced runner system. Despite geometrical balanced runner system, filling imbalances between cavity to cavity have always been observed. These filling imbalances are one of the most significant factors to affect quality of plastic parts. Filling imbalances are results from non-symmetrical shear rate distribution within melt when it flows through tile runner system. It has been possible to decrease filling imbalance by optimizing processing conditions, but it has not completely eliminated this phenomenon during injection molding processing. This paper presents a solution for these filling imbalances by using Runner Core pin (RC pin). The Runner Core pin which is developed in this study creates a symmetrical shear distribution within runner. As a result of using Runner Core pin, a remarkable improvement in reducing filling imbalances was confirmed.