• Title/Summary/Keyword: filed measurements

Search Result 40, Processing Time 0.024 seconds

Towards high-accuracy data modelling, uncertainty quantification and correlation analysis for SHM measurements during typhoon events using an improved most likely heteroscedastic Gaussian process

  • Qi-Ang Wang;Hao-Bo Wang;Zhan-Guo Ma;Yi-Qing Ni;Zhi-Jun Liu;Jian Jiang;Rui Sun;Hao-Wei Zhu
    • Smart Structures and Systems
    • /
    • v.32 no.4
    • /
    • pp.267-279
    • /
    • 2023
  • Data modelling and interpretation for structural health monitoring (SHM) field data are critical for evaluating structural performance and quantifying the vulnerability of infrastructure systems. In order to improve the data modelling accuracy, and extend the application range from data regression analysis to out-of-sample forecasting analysis, an improved most likely heteroscedastic Gaussian process (iMLHGP) methodology is proposed in this study by the incorporation of the outof-sample forecasting algorithm. The proposed iMLHGP method overcomes this limitation of constant variance of Gaussian process (GP), and can be used for estimating non-stationary typhoon-induced response statistics with high volatility. The first attempt at performing data regression and forecasting analysis on structural responses using the proposed iMLHGP method has been presented by applying it to real-world filed SHM data from an instrumented cable-stay bridge during typhoon events. Uncertainty quantification and correlation analysis were also carried out to investigate the influence of typhoons on bridge strain data. Results show that the iMLHGP method has high accuracy in both regression and out-of-sample forecasting. The iMLHGP framework takes both data heteroscedasticity and accurate analytical processing of noise variance (replace with a point estimation on the most likely value) into account to avoid the intensive computational effort. According to uncertainty quantification and correlation analysis results, the uncertainties of strain measurements are affected by both traffic and wind speed. The overall change of bridge strain is affected by temperature, and the local fluctuation is greatly affected by wind speed in typhoon conditions.

Time-lapse Geophysical Monitoring of $CO_2$ Sequestration (시간 경과에 따른 반복적 물리탐사 기법을 이용한 이산화탄소의 지중처리 모니터링)

  • Kim, Hee-Joon;Choi, Ji-Hyang;Han, Nu-Ree;Nam, Myung-Jin;Song, Yoon-Ho;Lee, Tae-Jong;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.4
    • /
    • pp.280-286
    • /
    • 2005
  • Geological sequestration of carbon dioxide ($CO_2$) is one of the most effective strategies far long-term removal of greenhouse gas from atmosphere. This paper reviews three projects for the $CO_2$ sequestration in geological formation. A unique $CO_2$ injection into a marine aquifer has been successfully monitored with repeated surface seismic measurements in the North Sea Sleipner West field. The seismic images reveal the extent and internal shape of the $CO_2$ bubble. Massive miscible $CO_2$ has been injected into a complex fractured carbonate reservoir at the Weyburn oil filed. High-resolution time-lapse P-wave data were successfully obtained to map the features of $CO_2$ movements within the two thin zones of different lithology. From the time-lapse crosswell EM imaging at the Lost Hills oil field in central California, U.S.A., the replacement of brine with $CO_2$ has been confirmed through a decrease of conductivity. The conductivity image was successfully compared with induction logs observed in the two wells.

Study on the Measurements of Flow Field around Cambered Otter Board Using Particle Image Velocimetry (PIV를 이용한 만곡형 전개판의 유동장 계측에 관한 연구)

  • 박경현;이주희;현범수;노영학;배재현
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.1
    • /
    • pp.43-57
    • /
    • 2002
  • This paper introduces an analysis method to predicting the flow characteristic of flow field around otter board In order to develope a high performance model. In this experiment, it is used a numerical analysis of flow field through CFD(Computational Fluid Dynamic), PIV method in which quantitative, qualitative evaluation is possible. In this experiment, it is used PIV method with flow filed image around otter board in order to analysis of flow characteristic. The result compared flow pattern with analysis result through CFD and also measurement result of lift and drag force coefficient carried out in CWC(Circulating Water Channel). The numerical analysis result is matched well with experiment result of PIV in the research and it is able to verify In the physical aspect. The result is as follows ; (1) It was carried out visibility experiment using laser light sheet, and picture analysis through PIV method in order to analysis fluid field of otter-board. As a result, the tendency of qualitative fluid movement only through the fluid particle's flow could be known. (2) Since PIV analysis result is quantitative, this can be seen in velocity vector distributions, instantaneous streamline contour, and average vorticity distributions through various post processing method. As a result, the change of flow field could be confirmed. (3) At angle of attack 24$^{\circ}$ where It Is shown maximum spreading force coefficient, the analysis result of CFD and PIV had very similar flow pattern. In both case, at the otter-board post edge a little boundary layer separation was seen, but, generally they had a good flow (4) As the result of post processing with velocity vector distributions, instantaneous streamline contour and average vorticity distributions by PIV, boundary layer separation phenomenon started to happen from angle of attack 24$^{\circ}$, and from over angle of attack 28$^{\circ}$, it happen at leading edge side with the width enlarged.

Gravity monitoring of $CO_2$ storage in a depleted gas filed: A sensitivity study (채굴후 가스전내 $CO_2$ 저장소의 중력 모너터링: 감도 연구)

  • Sherlock, Don;Toomey, Aoife;Hoversten, Mike;Gasperikova, Erika;Dodds, Kevin
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2006
  • In 2006, the Cooperative Research Centre for Greenhouse Gas Technologies (CO2CRC) plans to undertake (subject to receiving the necessary approvals) a Pilot program for $CO_2$ storage within a depleted gas reservoir. The Otway Basin Pilot Program (OBPP) aims to demonstrate that subsurface $CO_2$ storage is both economically and environmentally sustainable in Australia. This will be the first $CO_2$ storage program in the world to utilise a depleted gas reservoir and, hence, the experience gained will be a valuable addition to the range of international $CO_2$ storage programs that are underway or being planned. A key component of the OBPP is the design of an appropriate geophysical monitoring strategy that will allow the subsurface migration of the $CO_2$ plume to be tracked and to verify that containment has been successful. This paper presents the results from modelling the predicted gravity response to $CO_2$ injection into the Otway Basin reservoir, where the goal was to determine minimum volumes of $CO_2$ that may be detectable using non-seismic geophysical techniques. Modelling results indicate that gravity measurements at 10 m spacing within the existing observation well and the planned $CO_2$ injection well would provide excellent vertical resolution, even for the smallest $CO_2$ volume modelled (10000 tonnes), but resolving the lateral extent of the plume would not be possible without additional wells at closer spacing.

Design of a pen-shaped input device using the low-cost inertial measurement units (저가격 관성 센서를 이용한 펜 형 입력 장치의 개발)

  • Chang, Wook;Kang, Kyoung-Ho;Choi, Eun-Seok;Bang, Won-Chul;Potanin, Alexy;Kim, Dong-Yoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.247-258
    • /
    • 2003
  • In this paper, we present a pen-shaped input device equipped with accelerometers and gyroscopes that measure inertial movements when a user writes on 2 or 3 dimensional space with the pen. The measurements from gyroscope are integrated once to find the attitude of the system and are used to compensate gravitational effect in the accelerations. Further, the compensated accelerations are integrated twice to yield the position of the system, whose basic concept stems from the field of inertial navigation. However, the accuracy of the position measurement significantly deteriorates with time due to the integrations involved in recovering the handwriting trajectory This problem is common in the inertial navigation system and is usually solved by the periodic or aperiodic calibration of the system with external reference sources or other information in the filed of inertial navigation. In the presented paper, the calibration of the position or velocity is performed on-line and off-line. In the on-line calibration stage, the complementary filter technique is used, where a Kalman filter plays an important role. In the off-line calibration stage, the constant component of the resultant navigational error of the system is removed using the velocity information and motion detection algorithm. The effectiveness and feasibility of the presented system is shown through the experimental results.

Skeletal Factors Related to Open Lock of the Temporomandibular Joint (측두하악관절의 개구성 과두걸림 환자의 골격적 특성에 관한 연구)

  • Nam, Ji-Na;Lee, Jeong-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.3
    • /
    • pp.267-274
    • /
    • 2013
  • This study was performed to investigate the skeletal factors related to open lock of the temporomandibular joint(TMJ). We compared the skeletal measurements on the cephalogram and transcranial radiograph among 3 groups, open lock group consisting of consecutively filed 50 patients with at least one open lock episode within recent 1 year, temporomandibular disorder(TMD) group of 50 TMD patients without open lock diagnosed by Research Diagnostic Criteria for TMD (RDC/TMD) Axis I, and normal group of 50 patients without TMD or open lock. The patients of TMD and normal group were randomly selected in an age-and-gender-matched way with ones of open lock group. Open lock group showed smaller saddle angle than normal group on cephalograms and steeper inclination of the articular eminence than TMD and normal groups on transcranial radiographs. These results imply that the patients with the joint located more anterior and the articular eminence with steeper inclination might be riskier to TMJ open lock.

Flow Visualization in the Branching Duct by Using Particle Imaging Velocimetry (입자영상유속계를 이용한 분기관내 유동가시화)

  • No, Hyeong-Un;Seo, Sang-Ho;Yu, Sang-Sin
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.29-36
    • /
    • 1999
  • The objective of this study is to analyse the flow field in the branching duct by visualizing the flow phenomena using the PIV system. A bifurcation model is fabricated with transparent acrylic resin to visualize the whole flow field with the PIV system. Water was used as the working fluid and the conifer powder as the tracer particles. The single-frame and two-frame methods of the PIV system and 2-frame of the grey level correlation method are applied to obtain the velocity vectors from the images captured in the flow filed. The velocity distributions in a lid-driven cavity flow are compared with the so-called standard experimental data, which was obtained from by 4-frame method in order to validate experimental results of the PIV measurements. The flow patterns of a Newtonian fluid in a branching duct were successfully visualized by using the PIV system and the sub-pixel and the area interpolation method were used to obtain the final velocity vectors. The velocity vectors obtained from the PIV system are in good agreement with the numerical results of the 3-dimensional branch flow. The results of numerical analyses and the PIV experiments for the three-dimensional flows in the branch ing duct show the recirculation zone distal to the branching point and the sizes of the recirculation length and height of the tow different methods are in good agreement.

  • PDF

Evaluation of OSLD and EBT3 film for dose, energy, and angular dependence (OSLD와 EBT3 필름의 선량, 에너지, 방향의존성에 대한 평가)

  • Lee, Ju-seong;Kang, Bo-ram;Kwon, Hyeon-Kyung;Park, Ji-Young;Kim, Ju-Hye;Choi, Young-Se;Kim, Daehong
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • A radiation dosimeter is important to assess quality assurance (QA) of radiation therapy devices and to estimate the radiation dose in vivo dosimetry. Recently, optically stimulated luminescence detector (OSLD) is widely used in clinical filed. Therefore, the purpose of this study is to evaluate dose, energy, and angular dependence of OSLD and EBT3 film. The absorbed dose in clinical linear accelerator (Linac) beam is calibrated for dose per monitor unit (MU). Dose, energy, and angular dependence of OSLD and EBT3 film are estimated after the calibration procedure. The absorbed dose is measured at 50, 100, 150, and 200 cGy in an 6 MV X-ray beam for dose dependence. A dose of 150 cGy is delivered to OSLD and EBT3 film with 6 and 10 MV photon energies for energy dependence. For measurements of angular dependence, angular positions of gantry are $0^{\circ}{\pm}80^{\circ}$ with 6 MV at 150 cGy. The results of dose dependence is linear for OSLD and EBT3 film. For the results of energy dependence, errors were 0.39% and 0.03% for OSLD and EBT3 film, respectively. The results of dose for angular is decreased from $0^{\circ}$ to ${\pm}80^{\circ}$ for both OSLD and EBT3 film. When angle of $0^{\circ}$ is normalized to 1, and the dose is decreased to 60 and 66% at $80^{\circ}$ for OSLD and EBT3 film, respectively. Dose and energy dependence of OSLD and EBT3 film are measured within the recommendation of manufacturer. Angular dependence is increased from $0^{\circ}$ to ${\pm}80^{\circ}$ for OSLD and EBT3 film. The characteristics of OSLD and EBT3 film are similar and expected to useful for clinical field.

Multi-purpose Geophysical Measurements System Using PXI (PXI를 이용한 다목적 물리탐사 측정 시스템)

  • Choi Seong-Jun;Kim Jung-Ho;Sung Nak-Hun;Jeong Ji-Min
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.3
    • /
    • pp.224-231
    • /
    • 2005
  • In geophysical field surveys, commercial equipments often fail to resolve the subsurface target or even sometimes fail to be applied because they do not fit to the various field situations or the physical properties of the medium or target. We developed a geophysical measurement system, which can be easily adapted for the various field situations and targets. The system based on PXI with A/D converter and some stand alone equipment such as Network Analyzer was applied to borehole radar survey, borehole sonic measurement and electromagnetic noise measurement. The system for borehole radar survey consists of PXI, Network Analyzer, dipole antennas, GPIB interface is used for PXI to control Network Analyzer. The system for borehole sonic measurement consists of PXI, 24 Bit A/D converter, high voltage pulse generator, transmitting and receiving piezoelectric sensors. The electromagnetic noise measurement system consists of PXI, 24 Bit A/D converter, 2 horizontal component electric field sensors and 2 horizontal and 1 vertical component magnetic filed sensors. The borehole radar system has been successfully applied to detect the width of the artificial tunnel through which the borehole pass and to image buried steel pipe, while the commercial borehole radar equipment failed. The borehole sonic system was tested to detect the width of artificial tunnel and showed a reasonable result. The characteristic of electromagnetic noise was grasped at an urban area with the data from the electromagnetic noise measurement system. The system is also applied to characterize the signal distortion by induction between the electric cables in resistivity survey. The system can be applied various geophysical problems with a simple modification of the system and sensors.

Cephalometric Characteristics of TMD Patients based on RDC/TMD Axis I Diagnosis (RDC/TMD Axis I 진단에 따른 측두하악장애 환자의 측두 두부방사선적 특징에 관한 연구)

  • Ahn, Ji-Yeon;Kim, Yong-Woo;Kim, Young-Ku;Lee, Jeong-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.1
    • /
    • pp.39-51
    • /
    • 2011
  • The aims of this study were to investigate whether the facial skeletal patterns previously reported to be related to temporomandibular disorder (TMD) in other studies could be consistently observed in the TMD patients diagnosed according to Research Diagnostic Criteria for Temporomandibular Disorder (RDC/TMD) Axis I and evaluate its usability in the orthodontic clinics to examine the patients with TMD related symptoms. The clinical records and radiographs of female patients who visited the TMD and Orofacial Pain Clinic of Seoul National University Dental Hospital and were diagnosed as TMD were consecutively filed for this study. Patients were clinically examined and diagnosed according to the revised diagnostic algorithms of RDC/TMD Axis I and the lateral cephalogram, panoramic orthopantomogram, temporomandibular joint (TMJ) orthopantomogram, and transcranial radiograph of each patient were taken and digitalized. The data of patients who were under 18 years of age or had any systemic disease, trauma history involving the TMJ, or skeletal deformity at the time of the first examination were excluded. The remaining data of 96 female patients were finally analyzed. The obtained results were as follows: 1. There are no significant differences of cephalometric measurements between RDC I (muscle disorders) diagnostic groups. 2. Only the articular angle of the RDC group IIc (disk displacement without reduction without limited opening) patients was larger than patients of the no diagnosis of RDC II group (disk displacement). 3. Larger articular angle and smaller facial height ratio were observed in RDC IIIc group (osteoarthrosis) compared to IIIa group (arthralgia). Larger articular angle, larger Bjork sum, smaller posterior facial height, and smaller facial height ratio were observed in RDC group IIIc compared to no diagnosis of RDC III group (arthralgia, arthritis, and arthrosis). 4. According to the results of cephalometric analysis in simplified RDC groups, smaller overjet was observed in muscle disorders (MD) group. Facial height ratio and IMPA were smaller and articular angle was larger in disk displacements (DD) group than in no diagnosis of DD group. In arthrosis (AR) group, posterior facial height, and facial height ratio were smaller, and articular angle, gonial angle, facial convexity, FMA, Bjork sum, and ANB were larger than in no diagnosis of AR group. In joint pain (JP) group, only posterior facial height was smaller than no diagnosis of JP group. In conclusion, Facial morphologic patterns showing posterior-rotated mandible and lower posterior facial height is related to RDC group II and III diagnosis of the TMJ in female TMD patients. RDC/TMD Axis I diagnosis can provide a good clinical diagnostic tool for the standardized examination of the TMJ in orthodontic clinics.