• Title/Summary/Keyword: field test

Search Result 9,410, Processing Time 0.035 seconds

A Study on Analysis of the Physical Properties of Domestic and Foreign Sensitive Worsted Fabrics - Subjective hand assessments, Comparison between 1st and 2nd experiment - (국내.외 감성 소모직물의 물성분석에 관한 연구(II) - 주관적 태 평가, 1차, 2차 비교.분석 -)

  • Kim, Seung-Jin;Park, Kyung-Soon
    • Science of Emotion and Sensibility
    • /
    • v.11 no.1
    • /
    • pp.113-122
    • /
    • 2008
  • This study surveyed the physical properties of the domestic and foreign worsted fabrics which are used for men's garments. For this purpose, forty specimens which were divided into 1st fourteen specimens and 2nd twenty six ones were prepared and the physical property assessment by Blind field test was carried out by test committee. The subjective test items by Blind field test were chosen as handle(softness, flexibility), color(brightness, deepness), appearance(cleanness, natural lustre) and comparison priority.

  • PDF

Performance Test for the SIGMA Communication System

  • Jeong, Seonyeong;Lee, Hyojeong;Lee, Seongwhan;Shin, Jehyuck;Lee, Jungkyu;Jin, Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.335-344
    • /
    • 2016
  • Scientific CubeSat with Instruments for Global Magnetic Fields and Radiations (SIGMA) is a 3-U size CubeSat that will be operated in low earth orbit (LEO). The SIGMA communication system uses a very high frequency (VHF) band for uplink and an ultra high frequency (UHF) band for downlink. Both frequencies belong to an amateur band. The ground station that communicates with SIGMA is located at Kyung Hee Astronomical Observatory (KHAO). For reliable communication, we carried out a laboratory (LAB) test and far-field tests between the CubeSat and a ground station. In the field test, we considered test parameters such as attenuation, antenna deployment, CubeSat body attitude, and Doppler frequency shift in transmitting commands and receiving data. In this paper, we present a communication performance test of SIGMA, a link budget analysis, and a field test process. We also compare the link budget with the field test results of transmitting commands and receiving data.

Field Validation of alternative extraction method for the determination of airborne MWFs (대체용매를 이용한 금속가공유 측정방법 타당성에 대한 현장평가)

  • Jeong, Jee Yeon;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.96-101
    • /
    • 2009
  • The purpose of this study was to conduct the field validation of alternative method(ETM method) by using non-carcinogenic, and less toxic solvents than NIOSH (National Institute for Occupational Safety and Health) analytical method 5524 for measuring the airborne metalworking fluids in workplaces. We carried out the field validation test by using the exposure chamber, guaranteeing the air sampling homogeneously in a machining environment. The ETM mixed solvent presented the complete solubility of MWFs used in test field. Based on the field test data, the bias of the ETM method from reference method, NIOSH analytical method 5524, was from -7.0% to 5.1%. The overall uncertainty of the ETM nethod was 21.6%, which satisfied the NIOSH criteria for the sampling and analytical criteria.

A Study on Field-to-lab Test Method for the Safe Transport and Optimum Packaging Design of the Parcel Delivery in Korea (국내 택배화물의 안전운송 및 적정포장을 위한 Field-to-Lab 시험방법 연구)

  • Oh, Jae Young;Suh, Sang Uk;Lim, Mijin
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.127-132
    • /
    • 2022
  • The growth of e-commerce market requires more delivery packagings, which protect goods from the damage factors on the delivery. In this study, we have analyzed the distribution environment data (vibration and impact) measured in previous study and compared with global standards (ISTA, ASTM), so that we developed the testing method for Field-to-Lab simulation suitable to the domestic delivery. In order to verify the efficacy of this method, we took the Field-to-Lab tests for 3 packaged products (detergents set, glass tableware set, small furniture), which has been frequent breakages or damages on the actual delivery by e-commerce order, so that we could find out the test results were similar to those of the actual delivery occasions. In addition, we could perform redesign and improvement of the parcel delivery packagings for safe transportation by taking this Field-to-Lab test repeatedly. This test methods was finally proposed to be Korean industrial standard (KS), and is expected to be useful as a designing tool for the packaging optimization between protecting goods and reducing packaging waste.

Ride Performance Evaluation of a Heavy Truck Semi-active Cabin Air Suspension System (대형 트럭 반능동형 캐빈 공기 현가시스템의 승차감 성능 평가 연구)

  • Lee, Ji-Sun;Choi, Gyoo-Jae;Lee, Kwang-Heon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.77-83
    • /
    • 2008
  • Semi-active cabin air suspension system improves driver's comfort by controlling the damping characteristics in accordance with driving situation. For the driver's comfort evaluation, test procedure has the two methodologies which are filed test and lab test. A field test method has a drawback. It requires a lot of time and money on repetitive test, due to the sensitivity of field test. On the other hand, the test with six axes simulation table at laboratory can obtain the repeatability of test, better than the field test method. In this paper, the procedures of ride performance test and control logic tuning with the table are presented. Drive files of the table can be represented with the almost same input condition as field test data. According to the result from the comparative test using six axes simulation table between passive and semi-active system by making ECU logic tuning, the RMS acceleration of semi-active cabin air suspension system was reduced by 29.6% compared with passive system.

Effective Screening Method for Viviparous Germination of Rice

  • Ju, Young-Cheoul;Han, Sang-Wook;Park, Joong-Soo;Park, Kyeong-Yeol
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.45 no.2
    • /
    • pp.103-107
    • /
    • 2000
  • The viviparity of 28 rice varieties was tested at 25 days after heading(DAH), 35DAH, and 45DAH in the laboratory and field condition for 12 days. The incubation temperature was 20/l$0^{\circ}C$ (day/night), 25/15$^{\circ}$C$ and 30/20$^{\circ}$C$ in the laboratory test, and under field water conditions in the field test. The biggest varietal difference of viviparity was found in the laboratory test when examined at 45DAH with the 6-day incubation under 25/15$^{\circ}$C$ . At this conditions the mean viviparous ratio was 32.1 % with the range of 53.9 and the variance of 259.5. In the field test, the significant varietal difference in the viviparity was also found in the lodging treatment at 45 DAH for 6 days. Correlation coefficient analysis between the field and laboratory tests was highly significant from 4 days after incubation at 45 DAH and after 6-day incubation at 35 DAH, and correlation coefficient was higher as incubation days in the laboratory and submerged days under field water became longer. Considering the correlation between the field and laboratory tests, varietal difference of viviparity and convenience of testing, the laboratory test at 45 DAH for 6-day incubation under 25/15$^{\circ}$C$ was the most efficient evaluation method for the viviparity of rice cultivar.

  • PDF

A Study on the Ways of Securing the Effectiveness of Field Flame Retardant Coating Process (현장방염처리제도의 실효성 확보 방안에 관한 연구)

  • Park, Sung-Hyun;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.95-100
    • /
    • 2011
  • The ultimate purpose of this study is to improve the irrational system related to flame retardant coating performance test of field flame retardant coating articles and to secure the reliability of flame retardant coating through rational flame retardant coating test. To achieve this, the analysis was conducted on the interior finishing materials used in the interior fields and the trends of recent field flame retardant coating, based on the results of flame retardant coating performance test of field flame retardant coating articles which the first-line fire stations have recently conducted. And I attempted to present the methods of field flame retardant coating performance test suitable to current realities and the ways of improvement for securing reliability by analyzing the problems with the methods and procedures of field flame retardant coating articles and the registration system of flame retardant coating business.

A Study on the Field test of the Ready-mixed Shotcrete using in the Large-scale Mine (광산 대규격 갱도에 대한 레디믹스트 숏크리트의 현장 적용성 평가)

  • Kim, Dong-Min;Lee, Heung-Soo;Shin, Hong-Jun;Kang, Dong-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1511-1516
    • /
    • 2009
  • In recent years, the large-scale shaft have been appling in domestic mine for mass production using a large machine, the safety of mine also have been increasing. And the new trial that shotcrete of tunnel field was apply to mine support was progressed. But, the conditions of domestic mine was different from that of tunnel, so, the batch plant of tunnel could not be installed in mine field because of low economical efficiency and difficulty for selection of site. Ready-mixed Shotcrete that mixed with high quality materials and could be controled shotcrete quality is producted in plants and transported to field, so do not need to batch plant. In this study, The Field test of the Ready-mixed Shotcrete was performed in the large-scale mine and was compared with the quality of Field mix shotcrete. As the result of the Field test, compressive strength and rebound of Ready-mixed Shotcrete were superior to these of Field mix shotcrete.

  • PDF

Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案))

  • Kim, Seong-Hwan;Kim, Dong-Ho;Kim, Hyun-Oh;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF

Mode-Stirred Reverberation Chamber Characteristic to Stirrer Parameter and Usefulness Evaluation (교반기 매개변수에 따른 교반형 전자파 잔향실의 특성 및 유용성 평가)

  • Kim, Kwang-Yong;Hong, Joo-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1652-1657
    • /
    • 2010
  • This paper analyzes optimal stirrer parameter to improve field uniformity in a mode-stirred reverberation chamber. Stirrer parameter is varied about stirrer height and stirrer angle. Also we analyze quality factor, number of excited modes and stirrer efficiency that affect field uniformity. The results show good performance as higher as stirrer height. Isotropic field distribution is formed at $45^{\circ}$ stirrer angle. When stirrer angle varies, scattering characteristic of incident wave are changed. So electric field distribution in a mode-stirred reverberation chamber is also changed. Therefore, it affect field uniformity. The results expect to help that designs stirrer for get better field uniformity. Immunity test performed designed mode-stirred reverberation chamber for semiconductor that categorized by technology. Test result shows that good recurrence compared wave-guide immunity test.