• Title/Summary/Keyword: field samples

Search Result 2,171, Processing Time 0.026 seconds

The effect of fluoride-containing oral rinses on the corrosion resistance of titanium alloy (Ti-6Al-4V)

  • Huang, Gui-Yue;Jiang, Heng Bo;Cha, Jung-Yul;Kim, Kwang-Mahn;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.306-312
    • /
    • 2017
  • Objective: The purpose of this study was to examine the effect of commercially available fluoride-containing oral rinses on the corrosion behavior of titanium alloys, which are the main components of orthodontic miniscrews. Methods: Four commercially available oral rinses (solution A, pH 4.46/260 ppm fluoride; solution B, pH 4.41/178 ppm fluoride; solution C, pH 6.30/117 ppm fluoride; and solution D, pH 4.17/3.92 ppm fluoride) were tested on titanium alloy (Ti-6Al-4V) circular plates, and saline was used as the control. The open-circuit potential and potentiodynamic polarization of these materials were measured. Thereafter, all samples were evaluated under a field-emission scanning electron microscope. Results: Among the tested oral rinses, except solution D, the more the fluoride content was, the greater was the corrosion potential downtrend; the corrosion resistance of the titanium alloy sample was also lowered significantly (p < 0.05). Field-emission scanning electron microscopic analysis of the surface morphology of the titanium alloy samples revealed that all samples had some defects, crevices, or pitting after exposure to the oral rinses than before treatment. In particular, the samples in solution A showed the most changes. Conclusions: Commercially available oral rinses having a high fluoride concentration and a low pH may reduce the corrosion resistance of titanium alloys used in dental appliances such as orthodontic titanium miniscrews and brackets.

Assessment of Arsenic Levels in Body Samples and Chronic Exposure in People Using Water with a High Concentration of Arsenic: a Field Study in Kutahya

  • Arikan, Inci;Namdar, Nazli Dizen;Kahraman, Cuneyt;Dagci, Merve;Ece, Ezgi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3183-3188
    • /
    • 2015
  • Objective: This study aimed to evaluate the prevalence of skin lesions, which is a health effect of chronic arsenic (As) exposure, and determine the hair/blood arsenic concentrations of people living in Kutahya villages who are using and drinking tap water with a high concentration of arsenic. Materials and Methods: A total of 303 people were included in the present cross-sectional study. A prepared questionnaire form was used to collect the participants' information and environmental history. Skin examination was performed on all participants. Hair, blood and water samples were analyzed using atomic absorption spectroscopy. The cumulative arsenic index (CAI) was calculated for all participants. Results: Villages were divided into two groups according to the arsenic level (<$20{\mu}g/L$, Group I; >$20{\mu}g/L$, Group II) in their water. The prevalence of skin lesions, hair and blood arsenic level, and CAI were found to be higher in the Group II participants. There was a positive association between body arsenic levels and CAI in the participants of each group. Conclusions: The number of skin lesions and arsenic concentrations in body samples were found to increase with the water arsenic level and exposure time. We hope that sharing this study's results with local administrators will help accelerate the rehabilitation of water sources in Kutahya.

Standardization of an enzyme-linked immunosorbent assay for detection of antibody to avian reticuloendotheliosis virus (세망내피증 바이러스 항체검출을 위한 ELISA 표준화)

  • Sung, Haan Woo;Lee, Su Jeong
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.4
    • /
    • pp.569-574
    • /
    • 2005
  • Enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to reticuloendotheliosis virus (REV) at single serum dilution was standardized. REV HI, one of the Korean field isolates, was inoculated into chicken embryo fibroblast (CEF) cells and was harvested from the culture fluids and cells after 10 to 12 days. Viruses were purified by centrifugation at the $107,000{\times}g$ for 12 hours on 20, 30, 45% (W/V) sucrose gradient. Virus specific fraction was collected and used as ELISA antigen. To standardize ELISA, the optimal concentration of coating antigen ($1{\mu}g/well$) and conjugate (1/1000) was determined by corrected OD (OD value of positive serum-OD value of negative serum) and P/N ratio (OD value of positive serum/OD value of negative serum). To calculate ELISA titer by measuring absorbance at 1/400 single serum dilution, serum titrations were carried out for various sample sera together with standard positive and negative sera. The observed titers of serum samples were plotted against sample/positive (s/p) ratios at 1/400 serum dilution. From the above data, the ELISA titers could be calculated by the equation of $log_{10}$ ELISA titer = 2.2763 ($log_{10}$ s/p) + 3.482 (r = 0.93). For evaluating the sensitivity, the standardized method were compared with conventional agar gel immunodiffusion (AGID) test method using serum samples collected from REV infected field chicken flocks. Fifty seven of 60 samples (95%) were positive for REV by ELISA, whereas only 11 (18.3%) samples were positive by AGID test. This results suggested that the ELISA tests developed in this study could be used for detection of antibodies to REV with high sensitivity.

UNG-based direct polymerase chain reaction (udPCR) for the detection of porcine circovirus 2 (PCV2) (UNG 기반 direct polymerase chain reaction (udPCR)을 이용한 돼지 써코바이러스 2형 진단법)

  • Kim, Eun-Mi;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.37 no.4
    • /
    • pp.253-261
    • /
    • 2014
  • Porcine circovirus disease (PCVD) is a major problem of swine industry worldwide, and diagnosis of PCV2, causal agent of PCVD, has been doing in clinical laboratories of pig disease by polymerase chain reaction (PCR) methods. But the PCR analyses have a serious problem of misdiagnosis by contamination of DNA, in particular, from carryover contamination with previously amplified DNA or extracted DNA from field samples. In this study, an uracil DNA glycosylase (UNG)-based direct PCR (udPCR) without DNA extraction process and DNA carryover contamination was developed and evaluated on PCV2 culture and field pig samples. The sensitivity of the udPCR combined with dPCR and uPCR was same or better than that of the commercial PCR (cPCR) kit (Median diagnostics, Korea) on PCV2-positive serum, lymph node and lung samples of the pigs. In addition, the udPCR method confirmed to have a preventing ability of mis-amplification by contamination of pre-amplified PCV2 DNA from previous udPCR. In clinical application, 170 pig samples (86 tissues and 84 serum) were analysed by cPCR kit and resulted in 37% (63/170) of positive reaction, while the udPCR was able to detect the PCV2 DNA in 45.3% (77/170) with higher sensitivity than cPCR. In conclusion, the udPCR developed in the study is a time, labor and cost saving method for the detection of PCV2 and providing a preventing effect for DNA carryover contamination that can occurred in PCR process. Therefore, the udPCR assay could be an useful alternative method for the diagnosis of PCV2 in the swine disease diagnostic laboratories.

Physical and numerical modelling of the inherent variability of shear strength in soil mechanics

  • Chenari, Reza Jamshidi;Fatahi, Behzad;Ghoreishi, Malahat;Taleb, Ali
    • Geomechanics and Engineering
    • /
    • v.17 no.1
    • /
    • pp.31-45
    • /
    • 2019
  • In this study the spatial variability of soils is substantiated physically and numerically by using random field theory. Heterogeneous samples are fabricated by combining nine homogeneous soil clusters that are assumed to be elements of an adopted random field. Homogeneous soils are prepared by mixing different percentages of kaolin and bentonite at water contents equivalent to their respective liquid limits. Comprehensive characteristic laboratory tests were carried out before embarking on direct shear experiments to deduce the basic correlations and properties of nine homogeneous soil clusters that serve to reconstitute the heterogeneous samples. The tests consist of Atterberg limits, and Oedometric and unconfined compression tests. The undrained shear strength of nine soil clusters were measured by the unconfined compression test data, and then correlations were made between the water content and the strength and stiffness of soil samples with different consistency limits. The direct shear strength of heterogeneous samples of different stochastic properties was then evaluated by physical and numerical modelling using FISH code programming in finite difference software of $FLAC^{3D}$. The results of the experimental and stochastic numerical analyses were then compared. The deviation of numerical simulations from direct shear load-displacement profiles taken from different sources were discussed, potential sources of error was introduced and elaborated. This study was primarily to explain the mathematical and physical procedures of sample preparation in stochastic soil mechanics. It can be extended to different problems and applications in geotechnical engineering discipline to take in to account the variability of strength and deformation parameters.

Angular dependence of critical current of SmBCO coated conductor fabricated by co-evaporation method

  • Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo;Song, Kyu-Jeong;Ko, Rock-Kil;Ha, Dong-Woo;Kim, Tae-Hyung;Youm, Do-Jun;Lee, Nam-Jin;Moon, Seung-Hyun;Yoo, Sang-Im;Park, Chan
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.2
    • /
    • pp.16-19
    • /
    • 2008
  • Angular dependence of critical current density of SmBCO coated conductor fabricated by co-evaporation method was investigated. For comparison, three samples were fabricated by a co-evaporation method and one sample was fabricated by a pulsed laser deposition process. The deposition system, named EDDC (Evaporation using Drum in Dual Chambers), is a batch type co-evaporation system, which is composed of reaction chamber and evaporation chamber. The normalized critical current density ratio ($I_c/I_c$(H//ab-plane)) of EDDC-SmBCO samples was found to be higher than that of PLD-YBCO sample in the whole range of angle. While the EDDC-SmBCO samples evidently had a peak at the angle of H//c-axis in the plot of the angular dependence of critical current, the normalized critical current of PLD-YBCO sample decreased monotonically without any peak as angle increased. The field dependence of critical current under the magnetic field parallel to the normal direction of those samples showed similar aspect in the range of $0\;G{\sim}5000\;G$.

Template-Based Carbon Nanotubes Field Emitter

  • Jeong, Soo-Hwan;Lee, Ok-Joo;Hwang, Sun-Kyu;Lee, Kun-Hong
    • Journal of Information Display
    • /
    • v.2 no.3
    • /
    • pp.78-85
    • /
    • 2001
  • The growth of carbon nanotubes(CNTs) in anodic aluminum oxide(AAO) template and their application to a field emitter are described. AAO templates were fabricated by anodizing bulk aluminum and sputtered thin Al film on Nb-coated Si wafers. After Co catalyst had been electrochemically deposited into the bottom of the pores in AAO template, CNTs were grown by pyrolyzing $C_2H_2$. Depending on the reaction conditions, CNTs grew up to or over the top of the pores in AAO template with different structures. The morphology and structure of CNTs were observed with a scanning electron microscope and a transmission electron microscope. The diameter of CNTs strongly depended on the size of the pores in AAO template and the growing conditions. The electron field emission measurement of the samples resulted in the turn-on field of 1.9-2.2 $V/{\mu}m$ and the field enhancement factor of 2450-5200. The observation of high field enhancement factors is explained in terms of low field screening effect.

  • PDF

Molecular Typing and Antimicrobial Susceptibility of Staphylococcus aureus Strains Isolated from Raw Milk, Cheese, Minced Meat, and Chicken Meat Samples

  • Can, Hayriye Yesim;Elmali, Mehmet;Karagoz, Alper
    • Food Science of Animal Resources
    • /
    • v.37 no.2
    • /
    • pp.175-180
    • /
    • 2017
  • The objectives of this study were: i) to detect the presence of Staphylococcus aureus and methicillin-resistant S. aureus (MRSA) in raw milk, cheese, beef minced meat, and chicken meat samples; ii) to evaluate the antimicrobial susceptibility of the isolates; and iii) to determine clonal relation among the isolates by using pulsed-field gel electrophoresis (PFGE) method. Therefore, a total of 160 food samples were randomly collected between August 2014 and May 2015 in Hatay province, located in the southern Turkey. Twenty (12.5%) of the samples were found to be contaminated with S. aureus. A total of 40 isolates from the 20 positive samples were confirmed to be S. aureus by multiplex PCR based on 16S rRNA and nuc gene. The mec A gene was not detected in any of the S. aureus strains. In the present study, 39 out of 40 (97.5%) isolates were found to be resistant to one or more antibiotics. All of isolates were susceptible to gentamicin, oxacillin, and vancomycin. The highest resistance rate was detected in penicillin (95%) and ampicillin (92.5%), followed by tetracycline (30%), erythromycin (20%), ciprofloxacin (12.5%). Nine major patterns were determined by PFGE. In 6 of these patterns, thirty-six strains (90%) had identical PFGE profiles.

Development of Acoustic Resonance Evaluation System to Detect the Welding Defects (용접 불량 검사를 위한 음향공진 검사 장치 개발)

  • Yeom, Woo Jung;Kim, Jin Young;Hong, Yeon Chan;Kang, Joonhee
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.371-376
    • /
    • 2019
  • We have developed an acoustic resonance inspection system to inspect the welding defects in the mechanical parts fabricated using friction stir welding method. The inspection system was consisted of a DAQ board, a microphone sensor, an impact hammer, and controlled by a PC software. The system was developed to collect and analyze the sound signal generated by hitting the sample with an impact hammer to determine whether it is defective. In this study, 100% welded good samples were compared with 95%, 90%, and 85% welded samples, respectively. The variation of the completeness in welding did not affect the visual appearance in the samples. As a result of analyzing the natural frequencies of the good samples, the five natural frequency peaks were identified. In the case of the defective samples, the frequency change was observed. The welding failure detection time was fast enough to be only 0.7 seconds. Employing our welding defect inspection system to the actual industrial field will maximize the efficiency of quality inspection and thus improve the productivity.

Development of a Rapid PCR Test for Identification of Streptococcus agalactiae in Milk Samples Collected on Filter Paper Disks

  • Wu, Jiusheng;Liu, Yuehuan;Hu, Songhua;Zhou, Jiyong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.1
    • /
    • pp.124-130
    • /
    • 2008
  • Streptococcus (Strep.) agalactiae is one of the major pathogens of bovine mastitis and is the main cause of subclinical infection. This study attempted to develop a rapid PCR diagnosis procedure using milk samples collected on filter paper disks. Chromatographic filter paper was employed as the preservation media and kept at room temperature for one to four weeks. The revival rate of Strep. agalactiae kept on dried filter paper disks was affected by the pretreatment preservation time. The revival test suggested that not all the bacteria in artificially contaminated milk samples on the filter paper disks could be recovered. After that, a PCR based on the 16-23S intergenic spacer region of Strep agalactiae was performed. The results distinguished the strep. agalactiae from major pathogens of bovine mastitis at a $2{\times}10^2$ colony forming units (CFU)/ml level, which showed similar sensitivity to the results from liquid milk samples. The results also showed that milk samples collected on filter paper disks could be kept at room temperature for one to four weeks with little negative effect on sensitivity and specificity. The field test showed that the diagnostic sensitivity and specificity was 96.15% and 98.60%, respectively. In conclusion, the protocol will provide a rapid and economic procedure for the detection of bovine mastitis.