• Title/Summary/Keyword: field resistance

Search Result 2,422, Processing Time 0.031 seconds

A Study on 600 V Super Junction Power MOSFET Optimization and Characterization Using the Deep Trench Filling (Deep Trench Filling 기술을 적용한 600 V급 Super Junction Power MOSFET의 최적화 특성에 관한 연구)

  • Lee, Jung-Hoon;Jung, Eun-Sik;Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.4
    • /
    • pp.270-275
    • /
    • 2012
  • Power MOSFET(metal oxide silicon field effect transistor) operate voltage-driven devices, design to control the large power switching device for power supply, converter, motor control, etc. But on-resistance characteristics depending on the increasing breakdown voltage spikes is a problem. So 600 V planar power MOSFET compare to 1/3 low on-resistance characteristics of super junction MOSFET structure. In this paper design to 600 V planar MOSFET and super junction MOSFET, then improvement of comparative analysis breakdown voltage and resistance characteristics. As a result, super junction MOSFET improve on about 40% on-state voltage drop performance than planar MOSFET.

Preparation and Characteristics of Heat-releasing Sheet Containing AlN(alunimum nitride) Powder (AlN 분말을 이용한 방열 Sheet의 제조와 그 특성)

  • Kim, Sang-Mun;Lee, Seok-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.431-434
    • /
    • 2012
  • In this paper, heat-releasing sheets made of AlN powder and acryl binder as thermoset were prepared using tape casting method. The crystal structure and morphology, the thermal properties as nonvolatile solid content and thermal conductivity, and the surface resistance of heat-releasing sheet were measured by using X-ray diffractometer, field emission-scanning electron microscopy, thermo gravimetric analyzer and laser flash instrument, and surface resistance meter. It was proved that thermal conductivity is greatly affected by the content of binder in heat-releasing sheet. Superior thermal conductivity above 3.5 W/mK and suface resistance were obtained at heat-releasing sheet with above 90% of AlN powder.

Polymorphism in Intrinsic Antibiotic Resistance of Azospirillum Isolates from Ornamental Plants

  • Gadagi, Ravi;U., Krishnaraj P.;H., Kulkarni J.;Ahn, Ki-Sup;Sa, Tong-Min
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.5
    • /
    • pp.330-334
    • /
    • 2001
  • The polymorphism of Azospirillum isolates from ornamental rhizosphere and two reference strains were examined with respect to intrinsic antibiotic resistance (IAR) profile. All the isolates showed different intrinsic resistances to different antibiotics viz., tetracycline, kanamycin, nalidixic acid, streptomycin, ampicillin, spectinomycin and chloramphenicol. All the strains demonstrated susceptibility to high concentration of all antibiotics used in the present experiment. In addition to these general patterns, we also obseved the multiple antibiotic resistances of Azospirillum strains. The Azospirillum sp. OAD-11 was resistant to tetracycline, streptomycin and ampicillin, and Azospirillum sp. OAD-57 was resistant to tetracycline and streptomycin. Conversely, Azospirillum sp. OAD-9 possessed the dual susceptibility to tetracycline and spectinomycin, whereas Azospirillum sp. OAD-37 was dual susceptible to streptomycin and kanamycin. Such multiple antibiotic resistant/susceptible traits could be useful for the identification of the strains in field experiments or in molecular genetic transfer experiments.

  • PDF

Relationship Between Plant Viral Encoded Suppressor to Post-transcriptional Gene Silencing and Elicitor to R Gene-specific Host Resistance

  • Park, Chang-Won;Feng Qu;Tao Ren;T. Jack Morris
    • The Plant Pathology Journal
    • /
    • v.20 no.1
    • /
    • pp.22-29
    • /
    • 2004
  • Many important horticultural and field crops are susceptible to virus infections or may possess a degree of resistance to some viruses, but become infected by others. Plant viruses enter cells through the presence of wounds, and replicate intracellularly small genomes that encode genes required for replication, cell-to-cell movement and encapsidation. There are numerous evidences from specific virus-host interactions to require the involvement of host factors and steps during viral replication cycle. However, viruses should deal with host defense responses either by general or specific mechanisms, targeting viral components or genome itself. On the other hand, the host plants have also adapted to defend themselves against viral attack by operating different lines of resistance responses. The defense-related interactions provide new insights into the complex molecular strategies for hosts for defense and counter-defense employed by viruses.

Pobabilistic Design of Asphalt Pavement Surface Courae (아스팔트 鋪裝道路의 確率論的 表層設計)

  • Kim, Gwang-U;Yeon, Gyu-Seok
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.1
    • /
    • pp.66-77
    • /
    • 1992
  • A prototype probabilistic approach to thickness design for asphalt pavement surface course was developed using first-order second moment probability model. The tensile strain (load effect) developing at the bottom of surface layer due to the wheel load and the critical strain (resistance) of asphalt concrete were used as random variables for pavement reliability analysis. Based on the parameters for load effect and resistance data collected from reference and field, simulated data were generated by Monte Carlo method for reliability evaluation of the pavement for a typical rural highway. Thickness of pavement surface course was defined in terms of target reliability of the pavement, growth factor of traffic, design life of pavement and resistance of the asphalt concrete to be placed on the pavement. According to these rationales, prototype thickness design chrats were sugested through example studies. From these, similar design charts can be developed for many pavements if appropriate data and target reliability are determined.

  • PDF

Controlled Plasma Treatment for Edge Contacts of Graphene (그래핀의 엣지 접합 (Edge Contact)을 위한 플라즈마 처리 연구)

  • Yue, Dewu;Ra, Chang-Ho;Liu, Xiaochi;Daeyeong, Daeyeong;Yu, Won-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.293-293
    • /
    • 2014
  • The applicability of graphene has been demonstrated in the electronic fields. But, high performance of graphene is limited by the contact resistance (Rc) at the metal-graphene interface. Recently, Rc was found to be improved by forming edge-contacted graphene via theoretical simulation. Based on the differences between the surface and edge contacts at the M-G interface, we demonstrate "edge-contacted" graphene through the use of a controlled plasma processing technique that generates the edge structure of the bond and significantly reduces the contact resistance. The contact resistance attained by using pre-plasma processing was of $270{\Omega}{\cdot}{\mu}m$. Mechanisms of pre-plasma process leading to low Rc was revealed by SEM and Raman spectroscopy. In the end, controlled pre-plasma processing enabled to fabricate CVD-graphene field effect transistors with an enhanced adhesion and improved carrier mobility.

  • PDF

Measurement of Resistance of Multi-Grounded System by Ground Current Measurement (접지전류 측정에 의한 다중 접지계통의 접지저항 측정)

  • 최종기;안용호;정길조;한병성;김경철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.234-237
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

Accurate Formulas for Frequency-Dependent Resistance and Inductance Per Unit Length of On-Chip Interconnects on Lossy Silicon Substrate

  • Ymeri, H.;Nauwelaers, B.;Maex, K.;Roest, D.De;Vandenberghe, S.;Stucchi, M.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • A new closed-form expressions to calculate frequency-dependent distributed inductance and the associated distributed series resistance of single interconnect on a lossy silicon substrate (CMOS technology) are presented. The proposed analytic model for series impedance is based on a self-consistent field method and the vector magnetic potential equation. It is shown that the calculated frequency-dependent distributed inductance and the associated resistance are in good agreement with the results obtained from rigorous full wave solutions and CAD-oriented equivalent-circuit modeling approach.

Measurement of Resistance of Multi-Grounded System by Ground Current Measurement (접지전류 측정에 의한 다중 접지계통의 접지저항 측정)

  • 최종기;안용호;정길조;한병성;김경철
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.234-234
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

Corrosion Monitoring for Protected Systems using Thin-Film Electrical Resistance (TFER) Sensor

  • Lee, Seong-Min;Li, SeonYeob;Jung, Sung-Won;Kim, YoungGeun;Song, HongSeok;Won, Deok-Soo
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.112-116
    • /
    • 2006
  • This study has been conducted to monitor the corrosion rate of cathodically protected structure and corrosion inhibited system using multi-line thin-film electrical resistance (TFER) sensor in various environments. The field test data of TFER sensor for the corrosion monitoring of cathodically protected underground pipeline in soil environments and of corrosion inhibited gas heaters were also presented. The sensor was found to be a powerful method to commit the sensitive pick-up of small corrosion rate which can be observed in the cathodically protected and corrosion inhibited systems.