• 제목/요약/키워드: field decay measurement

검색결과 31건 처리시간 0.028초

자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정 (Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique)

  • 김정호;이승묵;주진호
    • Progress in Superconductivity
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

전력케이블 열화진단기법의 현장적용 (Field Application of Power Cable Diagnosis System)

  • 김주용;한재홍;송일근;김상준;이재봉;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

자장감쇄법을 이용한 Bi-2223/Ag 선재의 접합저항 측정 평가 (Measurement of joint resistance of Bi-2223/Ag tapes using field decay technique)

  • 김정호;김규태;주진호;최세용;나완수;하홍수;오상수
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.294-296
    • /
    • 2002
  • Considering the application of high temperature superconductor to MRI, the loss at conductor joint would be very important. Therefore, we have carried out a measurement of joint resistance of Bi-2223/Ag tapes at 77 K. A pancake coil was wound by Bi-2223/Ag tape. Both ends the tape were overlapped and soldered to each other. The DC current is induced in the pancake coil by energizing the excitation coil wound by copper wire closely located to the pancake coil. The decay behaviour of the current in coils was clearly separated in two regimes, and initial fast decay of the order of minutes followed by a slow logarithmic-like decay, From this data, the resistance of the joint was evaluated as 2.74 n$\Omega$.

  • PDF

Space Charge Measurement as a Diagnostic Tool to Monitor Ageing in Polymeric Materials

  • Chen, George
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.235-239
    • /
    • 2006
  • Charge dynamics in polymeric materials after aged under ac electric field using the pulsed electroacoustic (PEA) technique is reported. The emphasis is placed on charge decay. The charge dynamics of the ac aged additive free low density polyethylene (LDPE) samples under dc bias differ from the sample without ac ageing, indicating changes brought in by ac ageing. It is believed that a slow decay rate of charge in the ac aged sample is related to the formation of deep traps in the material. However, chemical analysis by infrared spectroscope (FTIR) and Raman microscope reveals no significant chemical changes taken place in the bulk of the material after ac ageing. Further experiments on irradiated LDPE have revealed a similar behaviour, i.e. the charge decay is slower in irradiated samples than that of fresh sample. The findings presented clearly indicate that space charge measurement can be used as a diagnostic tool to monitor ageing in polymeric materials.

수하식 양식시설에 의한 운수저항의 평가와 수치모형 (Evaluation and Numerical Model of Hydraulic Resistance by Hanging Aquaculture Facilities)

  • 이종섭;박일흠
    • 한국수산과학회지
    • /
    • 제28권5호
    • /
    • pp.607-623
    • /
    • 1995
  • A numerical model of hydraulic resistance by hanging aquaculture facilities is developed and applied to a model basin and a field. A drag stress term formulated by the quadratic law of drag force is introduced Tn the equations of motion for a two-dimensional depth-averaged flow. In the model basin, numerical experiments ave tarried out for the various shape of obstructions, string density and layout of facilities etc.. The flow pattern around the facilities is affected sensitively by the density of string and the layout of facilities. On the other hand, the velocity decay due to the hanging oyster aquaculture facilities is observed in Kamak bay, where the maximum velcocity decay rate is $25\%$ in spring tide. The model is also applied to the field, Kamak bay. The velocity decay rate in the model is comparable with the field measurement data. The velocity decreases around the down-stream area of the facilities, .hut it increases in the other region. The water elevation decreases during the flood and it increases during the ebb.

  • PDF

PIV/LIF에 의한 교반혼합기 유동의 난류 속도/농도장 측정 및 POD해석 (Simultaneous Measurement of Velocity and Concentration Field in a Stirred Mixer Using PIV/LIF Techniqueut and POD Analysis)

  • 정은호;윤상열;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2002
  • Simultaneous measurement of turbulent velocity and concentration field in a stirred mixer tank is carried out by using PIV/LIF technique. Instantaneous velocity fields are measured by a $1K\times1K$ CCD camera adopting the frame straddle method while the concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. It is found that the general features of the mixing pattern are quite dependent on the local flow characteristics during the rapid decay of mean concentration. However, the small scale mixing seems to be independent on the local turbulent velocity fluctuation.

  • PDF

레이저형광여기(LIF)를 이용한 비등온 제트유동의 온도장 측정 (Temperature Field Measurement of Non-Isothermal Jet Flow Using LIF Technique)

  • 윤정환;이상준
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1399-1408
    • /
    • 2000
  • A 2-dimensional temperature field measurement technique using PLIF (Planar Laser Induced Fluorescence) was developed and it was applied to an axisymmetric buoyant jet. Rhodamine B was used as a fluorescent dye. Laser light sheet illuminated a two-dimensional cross section of the jet. The intensity variations of LIF signal from Rhodamine B molecules scattered by the laser light were captured with an optical filter and a CCD camera. The spatial variations of temperature field of buoyant jet were derived using the calibration data between the LIF signal and real temperature. The measured results show that the turbulent jet is more efficient in mixing compared to the transition and laminar jet flows. As the initial flow condition varies from laminar to turbulent flow, the entrainment from ambient fluid increases and temperature decay along the jet center axis becomes larger. In addition to the mean temperature field, the spatial distributions of temperature fluctuations were measured by the PLIF technique and the result shows the shear layer development from the jet nozzle exit.

가입자 통신 선로에서의 뇌격 파라미터 분석과 측정 (Analysis and Measurement of Lightning Parameters on Subscriber Telecommunication Lines)

  • 오호석;박동철
    • 한국전자파학회논문지
    • /
    • 제18권11호
    • /
    • pp.1309-1317
    • /
    • 2007
  • 본 논문은 낙뢰에 의해 전송 선로에 유기되는 유도뢰 전압을 해석하고 낙뢰 위치 및 선로 길이에 따른 유도뢰 전압의 크기, 파두장, 파미장 등에 대한 낙뢰 파라미터 변화를 분석하였다. 분석한 결과를 확인하기 위해 실제 통신 선로를 대상으로 유도뢰 전압을 측정하였다. 선로 길이가 길어짐에 따라 그리고 낙뢰 위치가 선로와 멀어짐에 따라 파두장, 파미장이 증가하는 경향을 확인하였다. 전체 선로 길이보다는 가공 선로 길이가 상대적으로 유도 전압 크기에 영향을 끼침을 확인하였다.

도로 차선 재료의 공용수명 예측방법 (Methodology to Predict Service Lives of Pavement Marking Materials)

  • 오흥운;이현석;장정화;강재수
    • 한국도로학회논문집
    • /
    • 제10권4호
    • /
    • pp.151-159
    • /
    • 2008
  • 차선의 밝기를 나타내는 반사성능은 교통량, 도색 후 경과시간, 차선재료, 색상 등에 따라 지역별로 차이가 발생한다. 본 연구에서는 고속도로에서 조사된 차선 성능의 자료를 바탕으로 교통량과 차선의 공용수명을 독립변수로 하고 차선의 성능을 종속변수로 하는 회귀식을 산정하였다. 전국의 고속도로를 대상으로 모바일 차선반사 성능 차량을 사용하여 $2005{\sim}2006$년의 2년동안 3개월 간격으로 차선의 성능을 추적 조사하였다. 축적된 DB에는 차선의 성능뿐 아니라 차선의 재료, 색상, 기하구조, 교통량, 도색시기 등이 포함되어 있다. 본 연구에서 추적 조사된 차선성능을 기초로하여 다양한 환경에서의 차선재료의 성능을 비교 분석하여 여러 인자에 의한 차선성능 곡선을 도출하였다. 차선성능 곡선을 통해 지역별 교통량과 도색 이후의 시간의 경과에 따른 차선의 성능을 예측할 수 있었다. 선형함수, 로그함수, 지수함수, 음지수함수 등을 이용하여 차선의 성능을 나타내는 회귀식과 변동을 추정한 후, 결정계수가 가장 높고, 현장측정치와 가장 유사한 모형을 차선의 성능 예측모형으로 결정하였다. 현장조사 결과와의 검증결과, 차선성능 예측 모델은 90% 신뢰도에서 유의함을 볼 수 있었고, 특히 누적 교통량의 증가에 따라 현장 데이터와 높은 연관성을 보여주었다. 따라서 본 방법론에 의한 차선수명 예측 모델을 통해 차선의 공용수명과 잔존수명을 예측하여 도색시기를 결정할 수 있다.

  • PDF

PIV/LIF기법에 의한 교반혼합기 내의 속도장과 농도장 동시 측정 (Simultaneous Measurement of Velocity and Concentration Field in a Stirred Mixer Using PIV/LIF Technique)

  • 정은호;윤상열;김경천
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.504-510
    • /
    • 2003
  • Simultaneous measurements of turbulent velocity and concentration field in a stirred mixer tank are carried out by using PIV/LIF technique. Instantaneous velocity fields are measured with a 1K$\times$1K CCD camera adopting the frame straddle method while the concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. It is found that the general features of the mixing pattern are quite dependent on the local flow characteristics during the rapid decay of mean concentration. However, the small scale mixing seems to be independent on the local turbulent velocity fluctuation.