• 제목/요약/키워드: fiber volume fraction ratio

검색결과 129건 처리시간 0.028초

Performance of carbon fiber added to anodes of conductive cement-graphite pastes used in electrochemical chloride extraction in concretes

  • Pellegrini-Cervantes, M.J.;Barrios-Durstewitz, C.P.;Nunez-Jaquez, R.E.;Baldenebro-Lopez, F.J.;Corral-Higuera, R.;Arredondo-Rea, S.P.;Rodriguez-Rodriguez, M.;Llanes-Cardenas, O.;Beltran-Chacon, R.
    • Carbon letters
    • /
    • 제26권
    • /
    • pp.18-24
    • /
    • 2018
  • Pollution of chloride ion-reinforced concrete can trigger active corrosion processes that reduce the useful life of structures. Multifunctional materials used as a counter-electrode by electrochemical techniques have been used to rehabilitate contaminated concrete. Cement-based pastes added to carbonaceous material, fibers or dust, have been used as an anode in the non-destructive Electrochemical Chloride Extraction (ECE) technique. We studied the performance of the addition of Carbon Fiber (CF) in a cement-graphite powder base paste used as an anode in ECE of concretes contaminated with chlorides from the preparation of the mixture. The experimental parameters were: 2.3% of free chlorides, 21 days of ECE application, a Carbon Fiber Volume Fraction (CFVF) of 0.1, 0.3, 0.6, 0.9%, a lithium borate alkaline electrolyte, a current density of $4.0A/m^2$ and a cement/graphite ratio of 1.0 for the paste. The efficiency of the ECE in the traditional technique using metal mesh as an anode was 77.6% and for CFVF of 0.9% it was 90.4%, with a tendency to increase to higher percentages of the CFVF in the conductive cement-graphite paste, keeping the pH stable and achieving a homogeneous ECE in the mass of the concrete contaminated with chlorides.

비정질 강섬유 보강 일방향 콘크리트 슬래브의 전단성능에 대한 실험적 연구 (An Experimental Study of Shear Capacity for One-way Concrete Slabs Reinforced with Amorphous Micro Steel Fibers)

  • 김선두;최경규;최완철;최세진
    • 한국건설순환자원학회논문집
    • /
    • 제1권2호
    • /
    • pp.128-135
    • /
    • 2013
  • 본 연구에서는 비정질 강섬유보강 콘크리트 슬래브의 전단성능을 분석하기 위하여 일면 전단 실험을 수행하였다. 주요 변수는 전단보강방법과 전단보강비이며, 1종류의 무전단보강실험체와 3종류의 전단보강실험체(전단철근, 0.25%, 0.5% 비정질 강섬유보강 실험체)의 일방향 슬래브 실험체를 제작하여 실험하였다. 실험결과, 0.25% 비정질 강섬유보강실험체는 전단 성능이 향상되었지만 0.5% 실험체는 0.25% 보강실험체에 비해 전단성능이 향상되지 않았다. 섬유 보강비에 따른 전단보강 효과를 파악하기 위한 추가적인 연구가 필요하다.

섬유보강이 콘크리트의 역학적 특성과 철근콘크리트의 균열성상에 미치는 영향에 관한 연구 (Studies on the Effect of Fiber Reinforcing upon Mechanical Properties of Concrete and Crack Mode of Reinforoed Concrete)

  • 박승범
    • 한국농공학회지
    • /
    • 제20권2호
    • /
    • pp.4645-4687
    • /
    • 1978
  • This study was attempted to investigate the mechanical properties of concrete and crack control effects of reinforced concrete with steel and glass fiber. The experimental program includes tests on the properties of fresh concrete containing fibers, compressive strength, tensile strength, flexural strength, Young's modulus, Shrinkage and deformation of steel or glass fiber reinforced concrete. Also this study was carried out to investigate the effect of steel or glass fiber to retard the development in reinforced concrete subject to uniaxial tension and thus facilitate the use of steels of higher strength. The major conclusions that can be drawn from the studies are as follows: 1. The effect of the fibers in various mixes on fresh concrete confirmed that fibers do have a significant effect on the properties of fresh concrete, bringing much more stable and exhibiting a signiflcant reduction in surface bleeding, and that the cohesion is greatly improved and the internal resistance increases with fiber concentration. But the addition of an excess contents and length of fibers brings about the reduction of workability. 2. With the addition of steel fibers(1.5% Vol.) to concrete, the compressive strength as compared with plain concrete showed a very slight increase, but excess addition, over 1.5% Vol. of steel and glass fiber reduced its strength. 3. Splitting tensile strength of fiber reinforced concrete showed a significant increase tendency, as compared with plain concrete. In case of containing steel fiber (2.5%, 30mm), it showed that the maximum increase rate of 1.48 times as much rate, and in case of containing glass fiber (2.5%, 30mm), the increase rate of strength was 1.25 times as much rate. 4. Flexural strength of fiber reinforced concrete showed a significant tendency, as compared with plain concrete. Containing steel fiber (2.5%, 30mm) showed the maximum increase rate of 1.64 times as much rate and containing glass fiber (2.5%, 30mm) showed the increase rate of strength of 1.32 times as much rate, and in general, the 30mm length brougth the best results. 5. The strength ratio ($\sigma$b/$\sigma$c and $\sigma$t/$\sigma$c) increased, when steel fiber's average spacing was up to 3.05mm, but decreased when beyond 3.05mm, and it was confirmed that tensile or flexural strengths of steel fiber reinforced concrete are apparently governed by fiber's average spacing. 6. The compressive strain of fiber reinforced concrete showed a significant increasing tendency as the fiber was added, but Young's modulus. with the addition of steel and glass fibers, showed a slight decrease tendency. And according to the increase of flexural strength, a considerable increase was seen in toughness. 7. With the addition of fiber's the shrinkage of concrete was significantly decreased, in both case of adding steel fibers 12.5%, 30mm, and showed a significant decrease ratio, in average 30.4% and 36.7%, as compared with plain concrete. 8. With the increase of fiber volume fraction and length, the gained stress in reinforcing bar in concrete specimens increased in all crack widths, but at different rates, with the decrease of fiber diameter, the stress showed a considerable increasing tendency. And the duoform steel fibers showed the greatest improvement, as compared with the other types tested. 9. The influence of fiber dimensions in order of significanse on the machanical properties of concrete and the crack control of reinforced concrete was explained as follows: content, length, aspect ratio and dimeter.

  • PDF

후크형 및 스무스형 강섬유의 혼합 비율과 변형속도에 따른 하이브리드 섬유보강 시멘트복합체의 인장특성 (Tensile Properties of Hybrid Fiber Reinforced Cement Composite according to the Hooked & Smooth Steel Fiber Blending Ratio and Strain Rate)

  • 손민재;김규용;이상규;김홍섭;남정수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권3호
    • /
    • pp.31-39
    • /
    • 2021
  • 본 연구에서는 후크형 강섬유(HSF)와 스무스형 섬유(SSF)의 혼합 비율과 변형속도가 하이브리드 섬유보강 시멘트복합체의 인장 특성 시너지 효과에 미치는 영향을 평가하기 위하여, HSF와 SSF를 각각 1.5+0.5, 1.0+1.0, 0.5+1.0vol.%의 혼합 비율로 혼입한 하이브리드 섬유보강 시멘트복합체를 제작하였다. 실험 결과, HSF를 보강한 시멘트복합체(HSF2.0)은 변형속도가 증가함에 따라 섬유 주변 매트릭스에 발생하는 마이크로 균열의 증가에 의해 직선형으로 인발되는 섬유의 수가 감소하고, 인장강도 점 이후 응력 저하가 급격하게 발생하였다. SSF가 0.5vol.% 혼입되는 경우, 준정적에서 마이크로 균열을 효과적으로 제어하지만, 고속에서는 마이크로 균열 제어 및 후크형 강섬유의 인발저항성능 향상에 효과적이지 않은 것으로 확인되었다. 반면, HSF 1.0vol.%와 SSF 1.0vol.%를 혼입한 시험체(HSF1.0SSF1.0)은 마이크로 및 매크로 균열에 대해 각각의 섬유가 효과적으로 제어하고, SSF가 HSF의 인발저항성능을 향상시킴으로써 고속에서 변형능력 및 에너지 흡수 능력에 대한 섬유 혼합 효과가 크게 증가하였으며, 인장강도, 변형능력 및 피크인성의 변형속도 민감도가 가장 높은 것으로 나타났다. 반면, SSF 1.5vol.%의 혼입은 매트릭스 내의 섬유 혼입 개체 수를 증가시키고, HSF의 인발저항성능을 향상시켜 가장 높은 인장강도 및 연화인성 시너지 효과를 나타내었지만, 매크로 균열을 제어하는 HSF의 혼입률이 0.5vol.%로 낮아 변형능력 및 피크인성 시너지에는 효과적이지 않은 것으로 확인되었다.

Vibration analysis of functionally graded nanocomposite plate moving in two directions

  • Arani, Ali Ghorbanpour;Haghparast, Elham;Zarei, Hassan BabaAkbar
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.529-541
    • /
    • 2017
  • In the present study, vibration analysis of functionally graded carbon nanotube reinforced composite (FGCNTRC) plate moving in two directions is investigated. Various types of shear deformation theories are utilized to obtain more accurate and simplest theory. Single-walled carbon nanotubes (SWCNTs) are selected as a reinforcement of composite face sheets inside Poly methyl methacrylate (PMMA) matrix. Moreover, different kinds of distributions of CNTs are considered. Based on extended rule of mixture, the structural properties of composite face sheets are considered. Motion equations are obtained by Hamilton's principle and solved analytically. Influences of various parameters such as moving speed in x and y directions, volume fraction and distribution of CNTs, orthotropic viscoelastic surrounding medium, thickness and aspect ratio of composite plate on the vibration characteristics of moving system are discussed in details. The results indicated that thenatural frequency or stability of FGCNTRC plate is strongly dependent on axially moving speed. Moreover, a better configuration of the nanotube embedded in plate can be used to increase the critical speed, as a result, the stability is improved. The results of this investigation can be used in design and manufacturing of marine vessels and aircrafts.

강섬유로 보강된 반응성 분체 콘크리트의 부착특성과 쪼갬인장강도 (Bond Characteristics and Splitting Bond Stress on Steel Fiber Reinforced Reactive Powder Concrete)

  • 최현기;배백일;최창식
    • 콘크리트학회논문집
    • /
    • 제26권5호
    • /
    • pp.651-660
    • /
    • 2014
  • 강섬유로 보강되어 SF-RPC (Steel-Fiber reinforced Reactive Powder Concrete)로 불리는 초고성능 콘크리트의 설계는 이에 대한 연구결과를 기반으로 한 가이드라인을 통해 수행되고 있으나, 명확한 설계기준은 확립되지 않은 상태이다. 특히 SF-RPC 일반적으로 고온($90^{\circ}C$)의 증기양생을 필요로 하므로 프리캐스트 부재 형태로 사용되고 있어 부재간 접합 방법이 중요한 설계 요소로 간주됨에도 불구하고 명확한 설계기준이 존재하지 않음에 따라 현재 안전성 및 경제성 측면에서 많은 의문이 있는 상태이다. 본 연구에서는 SF-RPC의 명확한 정착 설계를 위한 기반으로 SF-RPC와 철근 사이의 부착강도를 실험적으로 파악하고, 기존에 사용하였던 평가 방법의 적용성을 검토하고자 한다. 이를 위해, 콘크리트의 압축강도, 피복두께, 섬유의 혼입량을 변수로 가진 직접 뽑힘 실험을 계획 및 수행하였다. 실험 결과 SF-RPC의 부착강도는 압축강도의 증가량에 따라 증가하고 있으나 그 증가율은 크게 나타나지 않음을 확인할 수 있으며, 피복두께의 증가에 따라 부착강도가 증가하며 $5.2d_b$ 이상의 피복을 가질 경우 매우 짧은 매입깊이인 $3d_b$의 매입깊이에서도 철근을 항복시킬 수 있는 것을 확인하였다. 또한, 섬유의 보강에 의해 부착강도가 두배 이상 증가하는 것을 확인하였다. 안전하고 경제적인 설계를 위해서는 SF-RPC의 부착강도를 추정할 수 있어야 하나, 현재까지는 이에 대한 추정식이 제시되고 있지 않으며, SF-RPC의 거동이 압축응력하에서는 큰 탄성 거동을 하며, 인장응력하에서는 소성거동을 함에 기인하여 Tepfers의 응력 해석 방법을 적용한 결과 실험 결과와 유사한 추정치를 기대할 수 있는 것을 확인하였다.

훅트강섬유보강 철근콘크리트보의 전단거동에 대한 실험적 연구 (Experimental Study on the Shear Behavior of Reinforced Hooked-Steel-Fiver Concrete Beams)

  • 심종성;이차돈;김규선;오홍섭
    • 콘크리트학회지
    • /
    • 제7권5호
    • /
    • pp.179-188
    • /
    • 1995
  • 강섬유보강콘크리트는 콘크리트의 취성을 극복하고 콘크리트 내의 강섬유의 구속작용과 균열제어메카니즘, pull-out저항 등에 의하여 강도가 증진되며 이러한 작용에 의하여 전단하중하에서도 강도와 연성의 증대를 가져온다. 강섬유보강콘크리트의 2차적인 보강효과는 휨보다는 전단거동에 대하여 더 효율적인 것으로 보고되고 있다. 따라서 시멘트계 재료에 훅트강섬유를 혼입함으로써 전단하중 하에서 훅트강섬유보강 철근콘크리트보(RHSFCB)의 전단저항력이 증가되고 결과적으로 보의 구조적 거동과 전단강도가 향상된다. 본 연구에서는 RHSFCB의 전단거동에 영향을 미치는 주요 변수들에 대한 각 영향을 실험적으로 고찰하였으며, 본 연구에서 고찰한 주요변수는 섬유혼입율, 전단-스팬비, 스터럽의 간격등이다. 이론적 고찰은 문헌에 보고된 각 전단강도 예측식들에 본 실험에서 전단파괴한 9개 시험체와 문헌에 나타난 86개의 전단파괴시험체를 적용하여 각 예측식들의 전단강도를 비교하였으며, 그 결과치를 통계분석하여전단강도예측식의 정확성을 고찰하였다.

Plastic기 복합재료의 파손강도 및 파괴인성에 미치는 원공크기의 영향 (The Effect of Hole Size on the Failure Strength and Fracture Toughness in Polymer Matrix Composite Plates)

  • 김정규;김도식
    • 한국재료학회지
    • /
    • 제3권2호
    • /
    • pp.197-204
    • /
    • 1993
  • Plastic기 복합재료의 파괴거동에 미치는 원공크기오 판폭의 영향을 검토하기 위하여 단축인장시험을 행하였다. 점응력파손조건에서의 특성길이 $d_o$는 원공크기 및 판폭에 의존하며, 이를 기초로 파손강도를 예측하기 위한 수정 점응력 파손조건식을 제안하였다. 이 파손조건의 예측값은 실험값과 잘 일치하였다. 파손 강도는 원공선단의 손상비의 증가에 따라 증가하며, 이는 손상영역의 형성으로 인한 응력완화현상으로 설명되어 진다. 또한 불안정 파괴시의 최대균열길이 $a_c$는 특성길이 $d_o$의 약 2배의 값을 나타낸다. 파괴인성에 대응하는 한계에너지해방율 $G_c$의 변화는 원공선단의 손상영역의 증가에 의한 응력완화가 주요한 원인이라고 할 수 있다.

  • PDF

한국산(韓國産) 주요(主要) 수종(樹種) 수피(樹皮)의 이학적(理學的) 성질(性質)에 관(關)한 연구(硏究) -소나무속(屬), 사시나무속(屬), 참나무속(屬)을 중심(中心)으로- (Studies on the Physical Properties of Major Tree Barks Grown in Korea -Genus Pinus, Populus and Quercus-)

  • 이화형
    • 한국산림과학회지
    • /
    • 제33권1호
    • /
    • pp.33-58
    • /
    • 1977
  • 수피(樹皮)는 원목(原木) 체적(體積)의 10~20%를 차지하고 있으며 일반적(一般的)을 운반(運搬), 제거(除去), 처리(處理)에 따른 비용에 비(比)해 효용가치(効用價値)는 적다. 뿐만아니라 세계적(世界的)인 임산자원(林産資源)의 부족(不足)에 따른 전수체이용화(全樹體利用化)의 개념이 점고(漸高)되면서부터 수피(樹皮)의 이용(利用)에 관심(關心)을 가지게 되었다. 본연구(本硏究)는 수피(樹皮)에 대(對)한 연구(硏究)가 전무(全無)한 국내(國內)의 실적(實積)에 비추어 국내주요(國內主要) 수종(樹種) 수피(樹皮)는 소나무속(屬), 사시나무속(屬), 참나무속(屬)을 대상(對象)으로 수피(樹皮)의 물리기계적(物理機械的) 성질(性質)을 구명(究明)하고 수피(樹皮)의 가능(可能)한 이용(利用) 책을 위한 기본적 성질을 밝히고자 하였다. 본(本) 연구(硏究)에서 사용(使用)한 공시수피(共試樹皮)는 서울대학교(大學校) 농과대학(農科大學) 부속연습림(附屬演習林)과 임업시험장(林業試驗場) 중부지장(中部支場) 부근에서 벌채이용(伐採利用)이 적령기(適齡期)에 달(達)하고 포고직경(胞高直徑)이 동급(同級)인 건전하고 정상적(正常的)으로 생장(生長)하는 입목(立木)의 흉고직경 부위(部位)에서 수종별(樹種別) 20주(株)씩 $200cm^2$로 채취(採取)하였다. 물리적(物理的) 성질(性質)로는 수피(樹皮) 전건비중(全乾比重), 내피(內皮) 및 외피(外皮)의 생수피(生樹皮) 함수량(含水量), 섬유포화점(纖維飽和點), 수분이력곡선(水分履歷曲線), 전수축율(全收縮率), 흡수량(吸收量), 비열(比熱), 습윤열(濕潤熱), 열전도도(熱傳導道), 열확산(熱擴散), 시차열분석(示差熱分析) 및 발열량(發熱量)을 측정(測定) 연구(硏究)하였다. 다음 기계적(機械的) 성질(性質)로는 곡강도(曲强度)와 압축강도(壓縮强度)를 측정연구(測定硏究)하였으며 본(本) 연구(硏究)에서 얻은 결론(結論)은 다음과 같다. 1. 전건비중(全乾比重)은 같은 개체(個體) 내(內)에 있어서도 목질부(木質部)와 수피간(樹皮間)에 차이(差異)가 있을 뿐아니라 수피(樹皮)에 있어서도 내피(內皮)와 외피간(外皮間)의 차이(差異)가 있다. 2. 수피(樹皮)의 전건비중(全乾比重)이 목질부(木質部) 비중(比重)보다 높은 사실(事實)은 수피내(樹皮內)의 사부섬유(篩部纖維) 및 보강세포(保强細胞)가 많이 있다는 해부적(解剖的)인 구조적(構造的) 특징(特徵)에 기인(基因)한다. 3. 전건비중(全乾比重)에 있어서 잣나무를 제외하고는 내피비중(內皮比重)이 외피비중(外皮比重)보다 높았으며 이는 내피(內皮)보다 높은 수축율(收縮率)에 기인(基因)한다. 4. 수피내(樹皮內)의 해부적(解剖的) 구조(構造)에 있어서 사요소(篩要素)의 구성비율(構成比率)이 높을수록 함수율(含水率)은 높아지고 후막조직(厚膜組織)과 주피조직(周皮組織)이 많으면 많을수록 함수율(含水率)은 떨어진다. 5. 수피(樹皮)의 섬유포화점(纖維飽和點)을 습윤열측정(濕潤熱測定)에 의(依)하여 구(求)할 수 있는 가능성(可能性)을 제시(提示)하였으며 그 결과(結果) 소나무에서는 26~28%사이에 상수리나무에서는 24~28%사이에 있는 것으로 나타났으나 이에 대(對)한 것은 금후연구(今後硏究)에 의(依)하여 더 밝혀져야 할 것이다. 6. 수피(樹皮)의 수축율(收縮率)은 목질부(木質部)와는 달리 경단방향(經斷方向)에서 제일 높고 수축방향(樹縮方向)에서 제일 낮았으나 졸참나무와 굴참나무에서는 열외(列外)이었다. 7. 수피(樹皮)의 비열(比熱)은 목질부(木質部)와 같고 습윤열(濕潤熱)은 목질부(木質部)보다 다소 높았다. 열전도도(熱傳導度)는 목재(木材)보다 낮으며 전건수피비중(全乾樹皮比重)과 수증기비중(水蒸氣比重)을 알고 열전도도(熱傳導度)를 계산할 수 있는 다음과 같은 회귀방정식(回歸方程式)을 유도(誘導)하였고 이 방정식(方程式)에 의(依)하여 얻어진 열전도도(熱傳導度) 수치는$(0.8{\sim}1.6){\times}10^{-4}cal/cm{\cdot}sec{\cdot}deg$이었다. $$K=4.631+11.408{\rho}d+7.628{\rho}m$$ 8. 수피(樹皮)의 열확산(熱擴散)은 $(8.03{\sim}4.46){\times}10^{-4}cm^2/sec$이며 시차열분석(示差熱分析)의 결과(結果)에 의(依)하면 발열량(發熱量)은 발열반응(發熱反應)이 시작(始作)되기 전(前)까지는 목질부(木質部)가 높고 발열반응(發熱反應)이 시작(始作)되면서부터는 수피(樹皮)가 목질부(木質部)보다 상회(上廻)하였다. 9. 경단방향(經斷方向)의 수피곡강도(樹皮曲强度)는 수피비중(樹皮比重)에 비례(比例)하고 회귀식(回歸式)은 M=243.78x-12.02(F=31.41)이었고 압축강도(壓縮强度)는 목질부(木質部)와는 달리 경단방향(經斷方向)이 가장 높고, 경단방향(經斷方向), 수축방향순(樹軸方向順)으로 적어졌다.

  • PDF