• 제목/요약/키워드: fiber surface

검색결과 2,359건 처리시간 0.029초

Fiber-Optic Sensor Simultaneously Detecting Localized Surface Plasmon Resonance and Surface-Enhanced Raman Scattering

  • Norov, Erdene;Jeong, Hyeon-Ho;Park, Jae-Hyoung;Lee, Seung-Ki;Jeong, Dae Hong
    • Rapid Communication in Photoscience
    • /
    • 제2권2호
    • /
    • pp.46-51
    • /
    • 2013
  • This study reports a fiber-optic sensor detecting biomolecule by simultaneously monitoring localized surface plasmon resonance (LSPR) from gold nanoparticles (Au NPs) of ca. $50{\pm}5$ nm attached on one end of optical fiber and surface enhanced Raman scattering (SERS) of the reporter molecules adsorbed on the gold surfaces as an additional sensing tool. The sensor was fabricated by immobilizing Au NPs on one end of an optical fiber by chemical reaction. LSPR and SERS signals of the sensor were measured using various refractive indices solutions. Finally, the sensor was applied to observe real-time LSPR sensor-gram and SERS spectra of the reporter molecule of 4-aminothiphenol during the antibody-antigen reaction of interferon-gamma (IFN-${\gamma}$) as a proof-concept experiment of biological applications.

Grafting of Casein onto Polyacrylonitrile Fiber for Surface Modification

  • Jia Zhao;Du Shanyi
    • Fibers and Polymers
    • /
    • 제7권3호
    • /
    • pp.235-240
    • /
    • 2006
  • Polyacrylonitrile (PAN) fiber was grafted with casein after alkaline hydrolysis and chlorination reactions of the original fiber. The structures and morphologies of the casein grafted fiber were characterized by Fourier transform infrared spectroscopy (FTIR), X-Ray diffraction (XRD), and scanning electron microscope (SEM). Moisture absorption, specific electric resistance, water retention value, and mechanical properties were also investigated. The results showed that casein was grafted onto the surface of the PAN fiber and the grafted PAN fiber presented better hygroscopicity compared with the untreated fiber. With proper tensile strength, the modified fiber could still meet the requirement for wearing. A mechanism was proposed to explain the deposit of casein on the synthetic acrylic fiber.

기능성 커플링제와 페놀수지에 의한 유리섬유 다발의 표면개질 연구 (Modification of glass fiber bundle with functionalized coupling agents and phenolic resin)

  • 이수
    • 한국응용과학기술학회지
    • /
    • 제33권1호
    • /
    • pp.168-175
    • /
    • 2016
  • 유리섬유 번들의 인장강도와 복합재료의 매트릭스수지인 페놀수지와의 접착성을 향상시키기 위하여 관능기를 가진 실란 커플링제와 페놀 수지를 이용하여 표면을 개질하였다. 일반적으로 보강재인 유리섬유의 표면을 화학적으로 개질하므로 복합재료의 특성을 조절할 수 있다. 본 연구에서는 에폭시계인 glycidyltrimethoxysilane(G-silane)과 아미노계 aminopropyltriethoxysilane (A-silane)과 페놀 수지를 사용하여 여러 농도와 온도에서 유리섬유 표면에 1단계 처리 및 2단계 복합처리를 수행하였다. 이 때 열처리 조건이 인장강도를 향상시키는 데 가장 중요하였다. 즉 $170^{\circ}C$에서 처리된 유리섬유의 인장강도가 $10.05g_f/D$로 최대를 나타내었다. 개질 후의 유리섬유 표면은 전자현미경과 적외선분광법을 이용하여 분석하였다. 실란의 종류와 처리 조건에 따른 유리 섬유 기계적 강도에 관한 영향도 고찰하였다.

Surface Characterization of Low Temperature Plasma Treated Wool Fiber - The Effect of the Nature of Gas-

  • Kan, C.W.;Chan, K.;Yuen, C.W.M.
    • Fibers and Polymers
    • /
    • 제5권1호
    • /
    • pp.52-58
    • /
    • 2004
  • Previous investigation results revealed that after the Low Temperature Plasma (LTP) treatment, the hydrophilicity of wool fiber was improved significantly. Such improvement enhances the wool dyeing and finishing processes which might be due to the changes of the wool surface to a more reactive one. In this paper, wool fibers were treated with LTP with different gases, namely, oxygen, nitrogen and gas mixture (25 % hydrogen/75 % nitrogen). Investigations showed that chemical composition of wool fiber surface varied differently with the different plasma gas used. The surface chemical composition of the different LTP-treated wool fibers was evaluated with different characterization methods, namely FTIR-ATR, XPS and saturated adsorption value. The experimental results were thoroughly discussed.

광섬유 TR-EFPI 센서를 이용한 GFRP 직교 적층판의 변형률 해석 (Strain Analysis in GFRP Cross-Ply Laminates Using TR-EFPI Optical Fiber Sensor)

  • 우성충;최낙삼;권일범
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.150-153
    • /
    • 2003
  • Longitudinal strains({$varepsilon}_x$) of the core and skin layers in glass fiber reinforced plastic(GFRP) cross-ply composite laminates have been studied using the embedded optical fiber sensor of totally-reflected extrinsic Fabry-Perot interferometer(TR-EFPI). Foil-type strain gauges bonded on both the upper and lower surfaces were used for the measurement of the surface strains. Both TR-EFPI sensor and strain gauge bonded on the specimen surface showed excellent agreement within -0.0086 ~ +0.0302% strain. It was shown that values of {$varepsilon}_x$ in the interior of the surface layer and the core layer measured by embedded TR-EFPI sensor was significantly higher than that of the specimen surface measured by strain gauges. The experimental results were ascertained with finite element analysis. Embedded TR-EFPI optical fiber sensor could measure accurately the internal strains which were different from the surface.

  • PDF

탄소섬유강화 복합재료의 자기연마 가공에 대한 표면특성 (Surface Characteristics with respect to Magnetic Abrasive Finishing in Carbon Fiber Reinforced Plastics)

  • 문상돈;송준희
    • 대한금속재료학회지
    • /
    • 제49권7호
    • /
    • pp.522-529
    • /
    • 2011
  • Carbon fiber reinforced plastics (CFRP), which have been developed for their high mechanical properties, are insufficient to secure machinery. This paper investigates the use of magnetic abrasive finishing methods and the characteristics of surface roughness for mirror machining of CFRP. The cylindrical surface of CFRP was ground using a diamond paste with sizes of 0.1, 0.5, 1 and 6${\mu}m$. Consequently, an effective surface roughness of 0.03${\mu}m(R_a)$ could be obtained via a paste size of 0.5${\mu}m$. The surface roughness was not improved due to epoxy abrasion between the carbon fiber and the epoxy.

Simultaneous active strain and ultrasonic measurement using fiber acoustic wave piezoelectric transducers

  • Lee, J.R.;Park, C.Y.;Kong, C.W.
    • Smart Structures and Systems
    • /
    • 제11권2호
    • /
    • pp.185-197
    • /
    • 2013
  • We developed a simultaneous strain measurement and damage detection technique using a pair of surface-mounted piezoelectric transducers and a fiber connecting them. This is a novel sensor configuration of the fiber acoustic wave (FAW) piezoelectric transducer. In this study, lead-zirconate-titanate (PZT) transducers are installed conventionally on a plate's surface, which is a technique used in many structural health monitoring studies. However, our PZTs are also connected with an optical fiber. A FAW and Lamb wave are simultaneously guided in the optical fiber and the structure, respectively. The dependency of the time-of-flight of the FAW on the applied strain is quantified for strain sensing. In our experimental results, the FAW exhibited excellent linear behavior and no hysteresis with respect to the change in strain. On the other hand, the well-known damage detection function of the surface-mounted PZT transducers was still available by monitoring the waveform change in the conventional Lamb wave ultrasonic path.

알칼리 감양가공이 Polyester 직물의 세척성에 미치는 영향 -표면구조의 효과를 중심으로- (A Study on the Detergency of Alkali-treated Polyester Fabric - The effects of surface structure-)

  • 신혜원;김성련
    • 한국의류학회지
    • /
    • 제10권2호
    • /
    • pp.1-9
    • /
    • 1986
  • To study the effects of surface structure of fiber on the decrement of fatty soil removal at high temperature, the following variables were selected: controled and alkali-treated P.E.T.(polyester) fabrics and chopped fibers as substrates to estimate the detergencies, different aging methods of soiled substrates, and different washing temperatures and surfactant solutions. Radiotagged tripalmitin was used as soil and the detergency was estimated by means of liquid scintillation counting method. The results were as following: The surface of the fiber became rough with many grooves and the hydrophilicity of the fiber was increased and the structure of the fabric became loose by alkali treatment. While the detergency of alkali-treated P.E.T. fabric was better than that of controled P. E. T. fabric, there was no significant differences between the detergencies of controled and alkali-treated chopped fibers. These results indicate that the increment of detergency of alkali-treated P.E.T. fabric is mainly resulted from the changes of fabric structure and the improved hydrophilicity of fiber by alkai treatment. The detergency of tripalmitin was increased with elevating temp. below the m.p. of tripalmitin, was decreased around the m.p., and again was increased above the m.p ..It is considered that the decrement of detergency around the m.p. is due to the diffusion of molten tripalmitin into the grooves on fiber surface, the inner part of fiber, and between fibers. When controled and alkali-treated soiled fabrics and soiled chopped fibers were washed in the distilled water and in the Na-DBS solution respectively, below $60^{\circ}C$ detergencies of alkali-treated fabrics and chopped fibers were improved. However above $60^{\circ}C$ this result was reversed. Therefore these results are regarded as the effects of grooves on fiber surface at high temp. and improved hydrophilicity at low temp. by alkali treatment. When controled and alkali-treated soiled fabrics and soiled chopped fibers were hot-aged before washing, the detergencies of both species were decreased generally. Because the soil was diffused into the grooves on fiber surface, the inner part of fiber, and between fibers during hot-aging. The detergencies of hot-aged species were also decreased above certain temp.. These results suggest that the decrement of detergency at high temp. be resulted not only from the diffusion of soil into the grooves on fiber surface, the inner part of fiber, and between fibers, but also from the characteristics of surfactant solutions.

  • PDF

Fiber network with superhydrophilic Si-DLC coating

  • 김성진;문명운;이광렬;김호영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.363-363
    • /
    • 2010
  • The high capillarity of a plastic fiber network having superhydrophilic Si-DLC coating is studied. Although the superhydrophilic surface maximize wetting ability on the flat surface, there remains a requirement for the more wettable surface for various applications such as air-filters or liquid-filters. In this research, the PET non-woven fabric surface was realized by superhydrophilic coating. PTE non-woven fabric network was chosen due to its micro-pore structure, cheap price, and productivity. Superhydrophobic fiber network was prepared with a coating of oxgyen plasma treated Si-DLC films using plasma-enhanced chemical vapor deposition (PECVD). We first fabricated superhydrophilic fabric structure by using a polyethylene terephthalate (PET) non-woven fabric (NWF) coated with a nanostructured films of the Si-incorporated diamond-like carbon (Si-DLC) followed by the plasma dry etching with oxygen. The Si-DLC with oxygen plasma etching becomes a superhydrophilic and the Si-DLC coating have several advantages of easy coating procedure at room temperature, strong mechanical performance, and long-lasting property in superhydrophilicity. It was found that the superhydrophobic fiber network shows better wicking ability through micro-pores and enables water to have much faster spreading speed than merely superhydrophilic surface. Here, capillarity on superhydrophilic fabric structure is investigated from the spreading pattern of water flowing on the vertical surface in a gravitational field. As water flows on vertical flat solid surface always fall down in gravitational direction (i.e. gravity dominant flow), while water flows on vertical superhydrophilic fabric surface showed the capillary dominant spreading.

  • PDF

자외선 처리된 Epoxy/Glass Fiber의 표면 열화 특성에 관한 연구 (A Study on the Surface Degradation Properties of Epoxy / Glass fiber Treated with Ultraviolet Rays)

  • 이백수;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.86-91
    • /
    • 1999
  • In order to analyse the degradation process of epoxy/glass fiber for outdoor condition, FRP laminate was exposed to the wavelength of ultraviolet rays and evaluated by comparing contact angle, surface resistivity, surface potential decay, and ESCA spectrum respectively. As irradiation energy are increased, the surface properties were steeply decreased in the range of 300[nm]. But the measured values within the scope of400[nm]∼440[nm] showed a increase as compared with the untreated ones. Also, fromthe result of ESCA spectrum, it was confirmed plenty of oxygen groups on the spot showing the maximum decrease of surface properties and the existence of ether groups on the surface of coloring phase. We can conclude that the degradation phenomena on the surface of epoxy composites are dominated by the induction of ester and carboxyl groups.

  • PDF