• Title/Summary/Keyword: fiber strength

Search Result 4,087, Processing Time 0.031 seconds

닭에서 고추씨박의 사료적 가치에 관한 연구

  • 임호중;강창원
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2001.11a
    • /
    • pp.24-39
    • /
    • 2001
  • These experiments were conducted to evaluate the nutritional and feeding value of red pepper seed oil meal (RPSOM) as local vegetable protein ingredients for poultry feeding. In the first experiment, nutritional values of RPSOM were evaluated by analyzing chemical compositions and determining true metabolizable energy (TME), nitrogen corrected TME (TMEn) and true available amino acid (TAAA) contents. According to the chemical analysis, RPSOM contained 22.50% of crude protein, 4.75% of ether extract, 27.70% of crude fiber, 0.34 mg/g of capsaicin and 49.97 ppm of xanthophylls. The values of TME and TMEn determined by force-feeding 16 roosters (ISA-Brown) were 1.73 kcal/g and 1.63 kcal/g on dry matter basis, respectively. The average TAAA value of 16 amino acids measured by the force-feeding technique was 81.70%. These values were used for formulating experimental diets containing various levels of RPSOM for broiler chicks and laying hens. Two feeding trials were made to investigate the effects of dietary incorporation of RPSOM into chicken feed performances of broiler chicks and laying hens. In the broiler feeding (Exp. 2), a total of two hundred twenty-five, 4 wk old male broiler chicks (Ross) were randomly divided into 9 groups of 25 birds each and assigned to three experimental diets containing 0, 5 and 10% RPSOM. The birds were fed ad libitum the diets for 3 wk and feed intake, weight gain and feed conversion rate were determined. At the end of the feeding, the blood levels of glutamate oxaloacetate transaminase (GOT), gamma glutamyl transpeptidase (GGT), blood urea nitrogen (BUN) and cholesterol, and the body and fatty acid compositions of leg muscle were measured. No significant differences were observed in weight gain, feed intake, feed conversion rate, body composition, serum levels of GOT, GGT and BUN among the treatments. However, blood cholesterol level was lower (P<0.05) in 10% RPSOM diet group than those in the other. The dietary RPSOM at 5 and 10% levels increased the content of linoleic acid (P<0.05) in leg muscle compared to that of control group. The results indicate that RPSOM can be used for broiler feed up to 10% without any significant negative effects on broiler performance. In the layer feeding (Exp. 3), the effects of dietary RPSOM on the performances of laying hen were investigated by feeding ninety 45 wk old laying hens (ISA-Brown) with experimental diets containing 0, 5 and 10% RPSOM for 4 wk (30 birds per treatment). Measurements were made on egg production rate, egg weight, feed intake, Haugh unit, egg shell strength which was higher (P<0.05) in layers fed 10% RPSOM diet compared to those fed 0 and 5% RPSOM diets. Thus, it can be concluded that RPSOM can be included into laying hen feed up to 10% without any harmful effects.

  • PDF

Effects of Preflocculated Filler Flocs and Nano-sized Coating Binder on Fold Cracking of Coated Paper (충전물 선응집체 크기와 나노 바인더에 의한 도공지의 접힘터짐 변화)

  • Im, Wanhee;Seo, Dongil;Oh, Kyudeok;Jeong, Young Bin;Youn, Hye Jung;Lee, Hak Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.5
    • /
    • pp.91-97
    • /
    • 2015
  • Papermakers wish to increase the filler content of printing and writing grades because it allows saving in production cost through fiber replacement and improving the formation, and optical and printing properties of the paper. However, high filler loading in the base paper has negative side effects. It reduces the mechanical properties of paper and induces cracking at the fold after coating process. Fold cracking is one of the most frequent quality complaints for magazines, high quality books, etc. Two approaches were examined as methods to reduce fold cracking. One approach was to use preflocculated fillers, which was expected to reduce the fold cracking because it would decrease the interfiber bonding. The other approach was to use a new coating binder that gives greater binding power and thereby provides an opportunity of reducing the fold cracking of coated paper. When filler preflocculation was employed in producing the base paper, fold cracking becomes more severe than conventional filler loading condition. On the other hand, use of nano sized binder in coating improved the tensile properties of the coating layer and thereby decreased the crack area. It was shown that tensile properties of coating layer played an important role in fold cracking of coating.

A Study on the Fracture Behavior of CFRP in Tensile and Fracture Toughness Tests by Acoustic Emission (음향방출법에 의한 탄소 섬유 복합 재료의 인장 및 파괴 인성시험시의 파괴 거동에 관한 연구)

  • Lee, Sang-Guk;Oh, Sae-Kyoo;Nam, Ki-Woo;Kim, Og-Gyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.1
    • /
    • pp.277-290
    • /
    • 1995
  • The study was carried out to analyze the fracture behavior and the acoustic emission(AE) characteristics and to find the relationship among tensile strength, fracture toughness and cure pressure in owe process of the carbon fiber reinforced composites of two types, $[0^{\circ}/90^{\circ}]_{2S}$ and $[0^{\circ}\;_2/90^{\circ}\;_2]_S$. AE signals were detected during the curing process, tensile tests and fracture toughness tests by acoustic emission(AE) measurements, respectively. Tensile strengths showed that the less cure pressurizing steps and the side of $[0^{\circ}/90^{\circ}]_{2S}$ specimens had the higher strengths than those of the others. Fracture toughness by the change of test temperature showed nearly same values in the same temperature region, but the higher test temperature had the lower fracture toughness values. In order to examine the relationship between fracture behavior of CFRP in tensile and fracture toughness tests and AE signals, the post processing for AE parameters of AE data and the observations of microscope and SEM have been carried out respectively.

  • PDF

Behavior of Hybrid Stud under Compressive Load (복합스터드의 압축 좌굴 거동)

  • Lee, Sang Sup;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.609-619
    • /
    • 2004
  • An investigation was conducted on the activities around Europe in order to solve the problem of the thermal bridging of steel studs, which had caused a significant disadvantage. This study included the following: diminishing the contact area between the studs and the sheathing, lengthening the heat transfer route, replacing the steel web with a less conductive material, and placing foam insulation in locations where the thermal shorts are most critical. Although energy efficiency is usually the focus of such foreign cases because their stud application is mostly limited to low-rise residential buildings, both structural and thermal performance are taken into consideration in this study because these target middle-story buildings. A hybrid stud composed of steel and polymer was also developed. This hybrid stud, which is 150 SL in size, is made of a galvanized steel sheet (SGC58) and a glass fiber reinforced polymer (GFRP) withepoxy bonding. A total of 32 specimens were manufactured. Its parameters comprise two types of connection detail,s: the thickness of steel (1.0mm and 1.2mm) and of the GFRP (4mm-4ply and 6mm-6ply), and the ratio of the length to the depth (L/D = 3, 6, 9, 12). Steel stud specimens with the same conditions were compared to the hybrid stud. The test revealed that in the case of the steel specimen with a thickness of 1.0mm, the maximum load of hybrid studs increased an average of 1.62 times comparedto that of the steel stud. In the case of the steel specimen with a thickness of 1.2mm, on the other hand, the average increase was 1.46times. All specimens showed full composite action until the collapse.

Structural analysis of flexible wing using linear equivalent model (선형 등가모델을 이용한 유연날개 구조해석)

  • Kim, Sung Joon;Kim, Dong Hyun;Lim, Joosup;Lee, Sang Wook;Kim, Tae-Uk;Kim, Seungho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.8
    • /
    • pp.699-705
    • /
    • 2015
  • Aircraft needs high lift-to-drag ratio and weight reduction of the structure for long endurance flight with a small power. Generally high aspect ratio wing is applied to HALE(High Altitude Long Endurance) aircraft. Also high modulus, and high strength CFRP(Carbon Fiber Reinforced Plastic) has been used in primary structures. and thin mylar(membrane material) film has been applied to skin of wing. As a result, wing is more flexible than the other structures. and the stiffness of thin mylar film has an affect on dynamic stability. In this study, the membrane characteristic of mylar film has been simulated using nonlinear gap elements. And equivalent modeling method using shell elements is presented using the nonlinear simulation result. The linear equivalent model has verified using the results of nonlinear membrane method. Proposed linear equivalent shell model has applied to mode analysis for estimate the effect of mylar mechanical properties on natural frequency.

Induction of Soft Tunic Syndrome by Water Temperature and Physiological and Histological Responses of the Sea Squirt, Halocynthia roretzi (수온에 의한 멍게(Halocynthia roretzi)의 물렁증 유도와 생리 및 조직학적 반응)

  • Shin, Yun Kyung;Park, Jung Jun;Myeong, Jeong In;Kim, Hyejin;Lee, Jung Sick
    • Korean Journal of Environmental Biology
    • /
    • v.32 no.3
    • /
    • pp.225-233
    • /
    • 2014
  • In this study, we investigated the changes in the physiological and histological traits of a sea squirt (Halocynthia roretzi) with the emergence of the soft tunic syndrome induced by the water temperature control (6, 9, 12, 15, 18, 21, 24 and $27^{\circ}C$). It was observed that the induction rate of the soft tunic syndrome was highest at $15^{\circ}C$, but lowest at $24^{\circ}C$. Based on the tunic color condition and contraction strength, the whole process were classified into 4 stages as S0, S1, S2 and S3. Interestingly, there were significant differences in oxygen consumption and filtration rate were observed during S0-S3. The most distinctive aspects were change of blood cell composition at stage S3, whereas multi-vacuole cell ratio was decreased by 1/2 and morula cell ratio expanded about 10 times during S0-S3. Further, change of organ structure started following the syndrome such as degeneration of epithelial cells, microfilaments, increment in hemocytes and damage in muscle fiber have been detected in tunic, siphon, branchial sac, body wall musculature and pyloric gland. Briefly, our study results indicated that the normal physiological functions of the sea squirt can be affected due to the soft tunic syndrome induced by water temperature.

A Study on the Preparation of Durable Softening Water-repellenting Agent by Blending Acrylic Copolymer and Fatty Carbamide - I. Water-repellent Finish of Cotton Fabrics - (아크릴 공중합체와 지방산 카르바미드의 블렌딩에 의한 내구유연발수제의 제조에 관한 연구 - I. 면직물에의 발수가공 -)

  • Kim, Young-Keun;Lee, Chong-Min;Park, Eun-Kyung;Park, Hong-Soo
    • Applied Chemistry for Engineering
    • /
    • v.5 no.2
    • /
    • pp.345-356
    • /
    • 1994
  • Each of the three cationized compounds synthesized previously, poly(OMA-co-DAMA)[PODC], poly(DMA-co-DAMA)[PDDC] and poly(EMA-co-DAMA)[PEDC] was blended with waxes, emulsifiers and cationized fatty carbamide(ODTCC) synthesized in this study for the preparation of some durable softening water-repellenting agents, PODCW, PDDCW and PEDCW. The results of washability, tearing strength, crease recovery and contact angle of the cotton fabrics treated with PODCW, PDDCW and PEDCW with and without textile finishing resin, showed remarkable improvement of the physical properties. Rating of water repellency of cotton fabric treated with PODCW was 80, but those treated with PDDCW and PEDCW were not high enough to use in industry. Proper curing temperature of the synthesized water-repelleting agents was $140^{\circ}C$; proper using concentration was 3wt%; sodium acetate was the best catalyst for water-repellenting agents among the used, and proper concentration was 0.6wt%. From the results of reaction mechanism of cellulosic fiber with water-repellenting agent and washability of the fibers treated with water-repellenting agents the prepared water-repellenting agent proved to be durable. Surface structures of cotton fabrics treated with water-repellenting agent were investigated by SEM.

  • PDF

Analysis of Thermal Shock Behavior of Cladding with SiCf/SiC Composite Protective Films (SiCf/SiC 복합체 보호막 금속피복관의 열충격 거동 분석)

  • Lee, Dong-Hee;Kim, Weon-Ju;Park, Ji-Yeon;Kim, Dae-Jong;Lee, Hyeon-Geon;Park, Kwang-Heon
    • Composites Research
    • /
    • v.29 no.1
    • /
    • pp.40-44
    • /
    • 2016
  • Nuclear fuel cladding used in a nuclear power plant must possess superior oxidation resistance in the coolant atmosphere of high temperature/high pressure. However, as was the case for the critical LOCA (loss-of-coolant accident) accident that took place in the Fukushima disaster, there is a risk of hydrogen explosion when the nuclear fuel cladding and steam reacts dramatically to cause a rapid high-temperature oxidation accompanied by generation of a huge amount of hydrogen. Hence, an active search is ongoing for an alternative material to be used for manufacturing of nuclear fuel cladding. Studies are currently aimed at improving the safety of this cladding. In particular, ceramic-based nuclear fuel cladding, such as SiC, is receiving much attention due to the excellent radiation resistance, high strength, chemical durability against oxidation and corrosion, and excellent thermal conduction of ceramics. In the present study, cladding with $SiC_f/SiC$ protective films was fabricated using a process that forms a matrix phase by polymer impregnation of polycarbosilane (PCS) after filament-winding the SiC fiber onto an existing Zry-4 cladding tube. It is analyzed the oxidation and microstructure of the metal cladding with $SiC_f/SiC$ composite protective films using a drop tube furnace for thermal shock test.

Behavior of Reinforcement Ratio on Concrete Beams Reinforced with Lab Spliced GFRP Bar (GFRP 보강근으로 겹이음된 콘크리트 보의 보강비에 따른 거동특성)

  • Choi, Yun Cheul;Park, Keum Sung;Choi, Hyun Ki;Choi, Chang Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.67-76
    • /
    • 2011
  • The use of glass-fiber-reinforced polymer (GFRP) bars in reinforced concrete (RC) structures has emerged as an alternative to traditional RC due to the corrosion of steel in aggressive environments. Although the number of analytical and experimental studies on RC beams with GFRP reinforcement has increased in recent decades, it is still lower than the number of such studies related to steel RC structures. This paper presents the experimental moment deflection relations of GFRP reinforced beam which are spliced. Test variables were different reinforcement ratio and cover thickness of GFRP rebars. Seven concrete beams reinforced with steel GFRP re-Bars were tested. All the specimens had a span of 4000mm, provided with 12.7mm nominal diameter steel and GFRP rebars. All test specimens were tested under 2-point loads so that the spliced region be subject to constant moment. The experimental results show that the ultimate moment capacity of beam increasing of the reinforcement ratio. Failure mode of these specimens was sensitively vary according to the reinforcement ratio. The change of beam effective depth, which was caused by cover thickness variation, controlled the maximum strength and deflection because of cover spalling in tension face.

A Study on the Flexural Capacity of Reinforced Timber Beams with the Inserting Method of CFRP Plates (탄소섬유판 삽입공법으로 보강된 목재보 휨강도에 관한 연구)

  • Kwon, Ki-Hyuk;Yu, Hye-Ran;Lee, Jin-Hyuk;Choi, Min-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • When historical or cultural buildings need to be repaired or reinforced, the changes of original features should be minimized, and the strengths of structures should be improved. Among the existing methods to reinforce historical wood structures, the carbon fiber reinforcement polymer (CFRP) installation method is one of the best ones to achieve the afore-mentioned requirements. Therefore, this study aims at investigating the reinforcing effects and failure modes of timber beams reinforced with the inserted CFRP, a part of roof trusses in modern wood structures, and at providing the fundamental test data to estimate the CFRP rein-forced timber beam in the application of this reinforcing method. The primary parameters in this study were the layout and amount of CFRP. It was observed that, when $0.3{\sim}0.7%$ of CFRP were installed, the strengths of reinforced timber beams increased up to 173% compared to its original strength, but their strengthening effects were heavily influenced by the characteristics of timber such as burls. In order to improve the applicability of this strengthening method, fundamental understandings on the characteristics of wood would be necessary, and there would be in need of researches on the non-destructive test for wood structures as well.