• 제목/요약/키워드: fiber space

검색결과 460건 처리시간 0.03초

Tension-Compression Asymmetry in the Off-Axis Nonlinear Rate-Dependent Behavior of a Unidirectional Carbon/Epoxy Laminate at High Temperature and Incorporation into Viscoplasticity Modeling

  • Kawai, M.;Zhang, J.Q.;Saito, S.;Xiao, Y.;Hatta, H.
    • Advanced Composite Materials
    • /
    • 제18권3호
    • /
    • pp.265-285
    • /
    • 2009
  • Off-axis compressive deformation behavior of a unidirectional CFRP laminate at high temperature and its strain-rate dependence in a quasi-static range are examined for various fiber orientations. By comparing the off-axis compressive and tensile behaviors at an equal strain rate, the effect of different loading modes on the flow stress level, rate-dependence and nonlinearity of the off-axis inelastic deformation is elucidated. The experimental results indicate that the compressive flow stress levels for relatively larger off-axis angles of $30^{\circ}$, $45^{\circ}$ and $90^{\circ}$ are about 50 percent larger than in tension for the same fiber orientations, respectively. The nonlinear deformations under off-axis tensile and compressive loading conditions exhibit significant strain-rate dependence. Similar features are observed in the fiber-orientation dependence of the off-axis flow stress levels under tension and compression and in the off-axis flow stress differential in tension and compression, regardless of the strain rate. A phenomenological theory of viscoplasticity is then developed which can describe the tension-compression asymmetry as well as the rate dependence, nonlinearity and fiber orientation dependence of the off-axis tensile and compressive behaviors of unidirectional composites in a unified manner. It is demonstrated by comparing with experimental results that the proposed viscoplastic constitutive model can be applied with reasonable accuracy to predict the different, nonlinear and rate-dependent behaviors of the unidirectional composite under off-axis tensile and compressive loading conditions.

Critical Design Status of the G-CLEF Flexure Control Camera

  • Oh, Jae Sok;Park, Chan;Kim, Kang-Min;Chun, Moo-Young;Yu, Young Sam;Lee, Sungho;Kim, Jihun;Nah, Jakyoung;Szentgyorgyi, Andrew;Podgorski, William;Evans, Ian;Mueller, Mark;Uomoto, Alan;Crane, Jeffrey;Hare, Tyson
    • 천문학회보
    • /
    • 제42권1호
    • /
    • pp.34.1-34.1
    • /
    • 2017
  • The GMT-Consortium Large Earth Finder (G-CLEF) is the very first light instrument of the Giant Magellan Telescope (GMT). The instrument is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement, and has been being developed through the international consortium consisted of five astronomical institutes including Smithsonian Astrophysical Observatory (SAO), Observatories of the Carnegie Institution of Washington (OCIW), and Korea Astronomy and Space Science Institute (KASI). The Preliminary Design Review (PDR) for the G-CLEF was held in Cambridge, Massachusetts in April 2015. It is scheduled to have Critical Design Review (CDR) in March 2018. Flexure Control Camera (FCC) is one of the KASI's major contributions to the G-CLEF project. In this presentation, we describe the current critical design status, and structural and thermo-elastic analyses results on the G-CLEF FCC.

  • PDF

Static and dynamic responses of Halgavor Footbridge using steel and FRP materials

  • Gunaydin, M.;Adanur, S.;Altunisik, A.C.;Sevim, B.
    • Steel and Composite Structures
    • /
    • 제18권1호
    • /
    • pp.51-69
    • /
    • 2015
  • In recent years, the use of fiber reinforced polymer composites has increased because of their unique features. They have been used widely in the aircraft and space industries, medical and sporting goods and automotive industries. Thanks to their beneficial and various advantages over traditional materials such as high strength, high rigidity, low weight, corrosion resistance, low maintenance cost, aesthetic appearance and easy demountable or moveable construction. In this paper, it is aimed to determine and compare the geometrically nonlinear static and dynamic analysis results of footbridges using steel and glass fiber reinforced polymer composite (GFRP) materials. For this purpose, Halgavor suspension footbridge is selected as numerical examples. The analyses are performed using three identical footbridges, first constructed from steel, second built only with GFRP material and third made of steel- GFRP material, under static and dynamic loadings using finite element method. In the finite element modeling and analyses, SAP2000 program is used. Geometric nonlinearities are taken into consideration in the analysis using P-Delta criterion. The numerical results have indicated that the responses of the three bridges are different and that the response values obtained for the GFRP composite bridge are quite less compared to the steel bridge. It is understood that GFRP material is more useful than the steel for the footbridges.

Nitrogen Porosimeter를 이용한 산소 플라즈마 처리 PET의 미세구조 분석 (The Analysis of the Micro-structure of Oxygen Plasma Treated PET Using a Nitrogen Porosimeter)

  • 김병인;김태경;조규민;임용진
    • 한국염색가공학회지
    • /
    • 제11권6호
    • /
    • pp.1-6
    • /
    • 1999
  • The porosities of PET fibers were investigated using a nitrogen porosimeter according to oxygen plasma treatment and dyeing with a disperse dye, and they were discussed in terms of the change of internal micro-structure of the PET fiber. The total pore volume, surface area and average pore size of the plasma treated PET fibers increased expectably compared with the untreated sample. The PET fibers treated with oxygen plasma and then dyed with a disperse dye were increased significantly in the surface area and the total pore volume comparing with those of plasma treated only, but decreased in the average pore size. The increase of the surface area, after dyeing, of the plasma treated PET fibers was due to addition of the surface area of the dye itself to that of the PET fiber. The increase of the total pore volume of the plasma treated PET fibers by dyeing, which is the opposite result to the general idea that the pore volume of fibers would be reduced by occupation of dye molecules in the pores, could be explained by the free-volume model. This is that the amorphous region in the fiber expanded by occupation of dye molecules, and the marginal space surrounding dyes was generated as many smaller pores, and the decrease of the average pore size of the dyed sample also could be explained The decrease of the average pore size was caused by the splitting of a larger pore into smaller pores.

  • PDF

고농도 펄프 슬러리 충전에서 PCC의 거동 (Behavior of PCC During Loading at High Consistency Pulp Slurry)

  • 조병욱;원종명
    • 펄프종이기술
    • /
    • 제43권5호
    • /
    • pp.43-48
    • /
    • 2011
  • Filler loading at thick stock was carried out in order to verify if the dual addition of filler can be used as a means to reduce the detrimental effects of filler on the strength properties of paper. PCC was added to 3.5% pulp slurry blended with HwBKP, BCTMP and SwBKP. Cationic starch was used as a fixing agent. The mixture of PCC and pulp was stirred for 5, 10 and 20min. at 1,000 rpm. The remaining PCC was washed out before handsheet making. PCC particles were flocculated and fixed on the pulp fiber and/or space between fibers. It is expected that the flocculation and inclusion of PCC can be helpful to improve the strength properties of paper due to the reduction of detrimental effect in fiber bonding. The distinct tendency in PCC flocculation and fixing on pulp fiber was not observed by the change of cationic starch dosage and treatment time.

배전자동화 개폐기에서 광전압센서에 관한 연구 (A study of Fiber-Optic Voltage Sensor in a distribution automated switch)

  • 오상기;김요희;서승현;이희철;양승국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 춘계종합학술대회
    • /
    • pp.493-496
    • /
    • 2000
  • 본 논문에서는 전계의 변화에 의한 굴절율의 변화에 따라 편광 상태가 달라지는 포켈스 소자인 BSO(Bi$_{12}$SiO$_{20}$)에 균등한 전계를 가하기 위해서 보조 전극을 이용한 공간분압방식을 채용하여 절연 신뢰도가 향상된 광전압 센서 모듈을 설계 제작하였다. 또한 항온 조를 이용하여 온도 변화에 따른 광전압센서의 출력특성을 측정하였으며, 광전압센서를 배전자동화 개폐기에 설치하여 60Hz의 교류전압을 6.6kV에서 17.8kV 까지 인가하여 측정한 결과 오차특성이 우수한 결과를 얻을 수 있다.

  • PDF

Esthetic rehabilitation of single anterior edentulous space using fiber-reinforced composite

  • Kim, Hyeon;Song, Min-Ju;Shin, Su-Jung;Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.220-225
    • /
    • 2014
  • A fiber-reinforced composite (FRC) fixed prosthesis is an innovative alternative to a traditional metal restoration, as it is a conservative treatment method. This case report demonstrates a detailed procedure for restoring a missing anterior tooth with an FRC. A 44-year-old woman visited our department with an avulsed tooth that had fallen out on the previous day and was completely dry. This tooth was replanted, but it failed after one year. A semi-direct technique was used to fabricate a FRC fixed partial prosthesis for its replacement. The FRC framework and the pontic were fabricated using a duplicated cast model and nanofilled composite resin. Later on, interproximal contact, tooth shape, and shade were adjusted at chairside. This technique not only enables the clinician to replace a missing tooth immediately after extraction for minimizing esthetic problems, but it also decreases both tooth reduction and cost.

All-fiber RGB Laser Light Source of Head-up Display System for Automobile Application

  • Lee, Jonggwan;Kim, Kyungwon;Son, Seong-Jin;Kim, Bok Hyeon;Yu, Nan Ei
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.221-228
    • /
    • 2020
  • We developed an all-fiber RGB laser light source module for application in an automobile head-up display. It is based on laser diodes and an optical fiber combiner that substantially enhances the flexibility of configuration and stability against harsh working conditions for automobiles. We coupled 13 laser diodes with optical fibers and merged them into a single output with a beam combiner device. Red (R), green (G), and blue (B) laser sources were employed to produce primary colors that were mixed into a white light output. An optical output power of approximately 1.5 W was achieved, and the color balance of the output lights was assessed based on the CIE 1931 color space. The optical output power was shown to be stable for over 160 h within an optical fluctuation of less than 0.27%.

Roles of polypropylene beads and pH in hybrid water treatment of carbon fiber membrane and PP beads with water back-flushing

  • Song, Sungwon;Park, Yungsik;Park, Jin Yong
    • Membrane and Water Treatment
    • /
    • 제10권2호
    • /
    • pp.155-163
    • /
    • 2019
  • The roles of polypropylene (PP) beads and pH on membrane fouling and treatment efficiency were investigated in a hybrid advanced water treatment process of tubular carbon fiber membranes (ultrafiltration (UF) or microfiltration (MF)) and PP beads. The synthetic feed including humic acid and kaolin flowed inside the membrane, and the permeated contacted the PP beads fluidized in the space between the membrane and the module with UV irradiation and periodic water back-flushing. In the hybrid process of UF ($0.05{\mu}m$) and PP beads, final resistance of membrane fouling ($R_f$) after 180 min increased as PP beads increased. The turbidity treatment efficiency was the maximum at 30 g/L; however, that of dissolved organic matters (DOM) showed the highest at PP beads 50 g/L. The $R_f$ strengthened as pH of feed increased. It means that the membrane fouling could be inhibited at low alkali condition. The treatment efficiency of turbidity was almost constant independent of pH; however, that of DOM showed the maximum at pH 5. For MF ($0.1{\mu}m$), the final $R_f$ was the minimum at PP beads 40 g/L. The treatment efficiencies of turbidity and DOM were the maximum at PP beads 10 g/L.

내방사 광섬유의 감마선 영향 분석 (Analysis of Gamma Radiation Effects of Commercial Radiation-Resistant Optical Fibers)

  • 류국빈;김영웅;김종열;황영관
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.620-622
    • /
    • 2022
  • 광섬유가 방사선에 노출되면 코어 내에 컬러센터가 형성되어 광 투과성이 저하된다. 방사선 유도 손실이라 하며, 소재, 구조 등의 변화를 통해 방사선 유도 손실을 줄이고 내방사선 특성을 개선한 광섬유가 활발히 연구되고 있다. 우주, 원자력 발전소 등 극한 환경에서도 통신 및 광응용 시스템을 구축하는데 내방사 광섬유를 활용할 수 있다는 장점 때문이다. 본 발표에서는 상용 내방사 광섬유의 감마선 조사에 의한 영향을 분석한 결과를 보인다.

  • PDF