• Title/Summary/Keyword: fiber sensor

Search Result 1,236, Processing Time 0.025 seconds

Fiber optic temperature sensor using optical intensity variation at optical communication wavelength range in side-polished fiber to thermo-optic polymer planar waveguide couplers (측면연마된 광섬유와 열광학 평면도파로 결합기에서 광통신 파장영역의 광세기변화를 이용한 광섬유형 온도센서)

  • 정웅규;김시홍;박형준;김광택;송재원;강신원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.252-253
    • /
    • 2000
  • 본 논문은 광통신 파장(1.3$mu extrm{m}$)에서 측면 연마된 광섬유와 열광학 평면도파로 결합기의 온도변화에 따른 광의 세기변화를 이용한 광섬유형 온도센서에 관한 연구이다. 본 연구에서 제안된 소자는 광통신영역에서 변화를 가지기 때문에 원거리 측정이 가능하고 열광학 평면도파로의 물질의 선택과 소자의 구조에 따라 넓은 온도감지 범위와 높은 분해능을 가지는 소자의 구현이 가능하다. (중략)

  • PDF

A Theoretical and Experimental Investigation into Pair-induced Quenching in Bismuth Oxide-based Erbium-doped Fiber Amplifiers

  • Jung, Min-Wan;Shin, Jae-Hyun;Jhon, Young-Min;Lee, Ju-Han
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.298-304
    • /
    • 2010
  • The pair-induced quenching (PIQ) effect in a highly doped bismuth oxide-based erbium-doped fiber amplifier (EDFA) was theoretically and experimentally investigated. In the theoretical investigation, the bismuth oxide-based EDFA was modeled as a 6-level amplifier system that incorporated clustering-induced concentration quenching, cooperative up-conversion, pump excited state absorption (ESA), and signal ESA. The relative number of paired ions in a highly doped bismuth oxide EDF was estimated to be ~6.02%, determined by a comparison between the theoretical and the experimentally measured gain values. The impacts of the PIQ on the gain and the noise figure were also investigated.

Rapid detection microfluidic immunosensor for food safety using static light scattering

  • Kim, Kee-Sung
    • 한국환경농학회:학술대회논문집
    • /
    • 2009.07a
    • /
    • pp.187-199
    • /
    • 2009
  • We present real.time, rapid detection of Mycoplasma pneumonia in phosphate buffered saline (PBS) inside a Y.channel polydimethylsiloxane (PDMS) microfluidic device by means of optical fiber monitoring of latex immunoagglutination. The latex immunoagglutination assay was performed with serially diluted Mycoplasma pneumonia solutions using highly carboxylated polystyrene particles of 390nm and 500nm diameter conjugated with monoclonal anti. Mycoplasma pneumonia . Proximity optical fibers were located around the viewing cell of the device, which were used to measure the increase in 45${\b{o}}$ forward light scattering of the immunoagglutinated particles. The detection limit was less than 50 $pgml^{-1}$ both for 390nm and 500nm microspheres with the detection time less than 90 seconds.

  • PDF

Sweeping Automatic Linearization for Wavelength Swept Laser Used in Structure Safety Monitoring (구조물 안전 모니터링용 파장 스위핑 레이저를 위한 스위핑 자동 선형화)

  • Lee, Duk-Kyu;Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.51-58
    • /
    • 2020
  • In this study, a novel method for sweeping automatic linearization of wavelength swept laser is proposed. Through the test performed on the implemented laser, the linear sweeping is held up well with a 97% decrease in nonlinearity, and 60 nm sweeping range, 1 kHz sweeping frequency, and 8.8 mW average optical power were obtained. The proposed method uses fiber Bragg grating array, optical-electronic conversion circuit, FPGA embedded module, and a LabVIEW program to generate new compensated wave patterns which were applied to the fiber Fabry-Perot tunable filter. Linear sweeping can reduce the cumbersome and time-consuming recalibration process required for nonlinear sweeping. Additionally, the proposed method provides more accurate measurement results for the structure safety monitoring system.

New Inchworm type Actuator with I/Q heterodyne Interferometer Feedback for a Long Stroke Precision Stage

  • Moon Chanwoo;Lee Sungho;Chung J.K
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.2
    • /
    • pp.34-39
    • /
    • 2005
  • The precision stage is an essential device for optic fiber assembly systems, micro machines and semiconductor equipments. A new piezoelectric inchworm type actuator is proposed to implement an actuator-integrated long-stroke linear stage. An in-and-quadrature phase (I/Q) heterodyne interferometer is developed as a feedback sensor of a servo system, and a synchronized counting method is proposed. The proposed measurement system can measure the accurate position of fast moving object with robustness to external sensing noise from actuator vibration. The developed servo stage will be applied to optic fiber device assembly system.

Structural Analysis and Proof Test of Composite Rotor Blades for Wind Turbine (풍력발전기용 복합재 블레이드의 구조 해석 및 인증시험)

  • Park, Sun-Ho;Han, Kyung-Seop
    • New & Renewable Energy
    • /
    • v.4 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • GFRP based composite rotor blades were developed for 750 kW & 2 MW wind turbines. The blade sectional geometry was designed to have a general shell-spar and shear web structure. For verifying the structural safety under all relevant extreme loads specified in the GL guidelines, the structural analysis of the rotor blades was performed using commercial FEM codes. The static load carrying capacity, blade tip deflections and natural frequencies were evaluated to satisfy the strength and stability requirements. Full-scale proof tests of rotor blades were carried out with optical fiber sensors for real-time condition monitoring. Finally, the prototype of each rotor blade passed all proof tests for GL certification.

  • PDF

Implementation of a self-mixing type LDF probe and blood flow simulator (자기혼합형 LDF 프로브와 혈류 시뮬레이터의 구현)

  • Ko, Han-Woo;Kim, Jong-Weon
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.133-138
    • /
    • 1999
  • In this pager, the authors have implemented a blood flow simulator and a LDF(laser Doppler flowmeter) probe using self-mixing effect of the laser diode. The purpose of the blood flow simulator is to simulate microvascular blood flow in tissue. It consists of melinex film (thickness = $123\;{\mu}m$) which has similar optical characteristics to epidermis and porous polyethylene filter (Vyon, porosity 35%, mean pore size $50\;{\mu}m$, thickness=1 mm) which has similar optical characteristics to dermis. The blood flowmeter probe consists of laser diode(5 mW, 780 nm wavelength), CD lens(focal length 12 mm). current-to-voltage converter, highpass filter, and premplifier. It doesn't need optical fiber, therefore, implementation of the probe is simpler than conventional probe using optical fiber.

  • PDF

Effect of Steady and Relaxation Oscillation in Brillouin-Active Fiber Ring Structural Sensors (유도 브릴루앙-파이버 링센서에서 비안정화 현상)

  • Kim, Yong-Kab;Lee, Byeong-Ha;Paek, Un-Chul
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.208-209
    • /
    • 2003
  • We have developed a practical Brillouin active fiber ring sensor of length less than 20m, by employing an optical amplifier to compensate for most of the connection losses in the ring. The loss reduction brings the standard Brillouin threshold from 21 down to 0-0.1 through the enhancement of the finesse of the ring. However, in the course of our experiments, some level of temporal instability and chaotic behavior in the backscattered Stokes intensity and also in its spectral line shift were consistently observed. (omitted)

  • PDF

Static Behavior of Hollow Cantilever Beam using Multiplexed FBG Sensors (다중화된 FBG 센서를 이용한 중공 내민보의 정적 거동 분석)

  • Lee, Tae-Hee;Kang, Dong-Hoon;Chung, Won-Seok;Mok, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.593-598
    • /
    • 2009
  • This paper presents a preliminary study to monitor the lateral behavior of pile foundation using multiplexed fiber Bragg grating (FBG) sensors. In the preliminary study, an 1.7 meter long cantilever beam with the shape of square hollow box was fabricated and tested under the static loading. Four FBG sensors were multiplexed in a single optical fiber and installed into the top and bottom of the cantilever beam. The strains are directly measured from FBG sensors followed by curvature calculations based on the plane section assumption. Vertical deflections are then estimated using the regression analyses based on the geometric relationships. It has been found that excellent correlation with conventional sensing system was observed. The success of the test encourages the use of the FBG sensing system as a monitoring system for pile foundations. However, further consideration should be given in the case of the sensor malfunction for the practical purpose.

  • PDF

Real-time Monitoring of Ethernet Passive Optical Network Using Burst-mode FBGs

  • Binh, Nguyen Khac;Choi, Su-il
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.186-192
    • /
    • 2020
  • This paper describes a real-time monitoring system in Ethernet passive optical networks (EPON) that uses burst-mode fiber Bragg grating (FBG) optical sensors. The FBG interrogation unit in the optical line terminal (OLT) transmits the monitoring wavelength to optical network units (ONUs). The FBG sensor unit in each ONU returns a burst-mode monitoring signal to the OLT. As the system applies time division multiple access (TDMA), a uniform Bragg wavelength can be used to monitor the EPON system. The FBG interrogation unit analyzes the received burst-mode monitoring signals and outputs fault information on the ONU branches in EPON. The simulation results show the effectiveness of the proposed monitoring system based on TDMA. In addition, we compared the proposed TDMA-based monitoring system with a WDMA-based monitoring system.