• 제목/요약/키워드: fiber beam

검색결과 1,187건 처리시간 0.021초

FRC를 적용한 FRP-콘크리트 합성보의 거동특성 (Behavior Characteristics of FRP-Concrete Composite Beam using FRC)

  • 조정래;조근희;김병석;진원종;김성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.742-745
    • /
    • 2004
  • The FRP-concrete composite deck system has advantages of corrosion free and easy construction. The system is, however, comprised of two brittle materials, so that it suffers from inherent disadvantage of lack of ductility. In this study, some conceptual design is presented for preventing the brittle failure of FRP-concrete composite deck at ultimate load level. 4-point bending tests are performed for FRP-concrete composite beams using FRC(Fiber Reinforced Concrete). The specimens use the box-shape FRP member in the lower portion. Four types of concrete with different compressive strengths and ductilities including normal mortar and 3 FRCs are placed in the upper portion. Typical failure mode in the test is identified; Concrete compressive failure occurs first at the maximum moment region, and the interfacial debonding between FRP and concrete member proceeds. Finally, the tensile rupture of FRP member occurs. The specimen using FRC with the high compressive ductility of concrete fails with less brittle manner than other specimens. The reason is that the ductility from the concrete in compression prevents the sudden loss of load-carrying capacity after compressive concrete failure.

  • PDF

Flexural Strength of RC Beam Strengthened by Partially De-bonded Near Surface-Mounted FRP Strip

  • Seo, Soo-yeon;Choi, Ki-bong;Kwon, Young-sun;Lee, Kang-seok
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권2호
    • /
    • pp.149-161
    • /
    • 2016
  • This paper presents an experimental work to study the flexural strength of reinforced concrete (RC) beams strengthened by partially de-bonded near surface-mounted (NSM) fiber reinforced polymer (FRP) strip with various de-bonded length. Especially, considering high anchorage capacity at end of a FRP strip, the effect of de-bonded region at a central part was investigated. In order to check the improvement of strength or deformation capacity when the bonded surface area only increased without changing the FRP area, single and triple lines of FRP were planned. In addition, the flexural strength of the RC member strengthened by a partially de-bonded NSM FRP strip was evaluated by using the existing researchers' strength equation to predict the flexural strength after retrofit. From the study, it was found that where de-bonded region exists in the central part of a flexural member, the deformation capacity of the member is expected to be improved, because FRP strain is not to be concentrated on the center but to be extended uniformly in the de-bonded region. Where NSM FRP strips are distributed in triple lines, a relatively high strength can be exerted due to the increase of bond strength in the anchorage.

축대칭 하향단흐름에서 자유흐름 난류강도의 영향 (Effects of the free Stream Turbulence Intensity on the Flow Over an Axisymmetric Backward-Facing Step)

  • 양종필;김경천;부정숙
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2328-2341
    • /
    • 1995
  • An experimental study on the flow over the axisymmetric backward-facing step was carried out. The purposes of the present study are to investigate the effect of the free stream turbulence intensity on the reattachment length and to understand the turbulence structure of the recirculating flows. Local mean and fluctuating velocity components were measured in the separated and reattaching axisymmetric turbulent boundary layer over the wall of convex cylinder placed in a water tunnel by using 2-color 4-beam fiber optics laser Doppler velocimetry. As the free stream turbulence intensity increased, the reattachment length became shorter due to the enhanced mixing in the separated shear layer. It was also observed that the reverse flow velocity and turbulent kinetic energy increase with increasing free stream turbulence intensity. Spectral data and flow visualization showed that low-frequency motions occur in the separated flow behind a backward-facing step. These motions have a significant effect on the time-averaged turbulence data.

Nonlinear finite element analysis of RC beams strengthened with CFRP strip against shear

  • Bulut, Nalan;Anil, Ozgur;Belgin, Cagatay M.
    • Computers and Concrete
    • /
    • 제8권6호
    • /
    • pp.717-733
    • /
    • 2011
  • Strengthening of reinforced concrete (RC) members against shear that is one of the failure modes especially avoided by using carbon fiber reinforced polymer (CFRP) is widely used technique, which is studied at many experimental studies. However, conducting experimental studies are required more financial resources and laboratory facilities. In addition, along with financial resources, more time is needed in order to carry out comprehensive experimental studies. For these reasons, a verified finite element model that is tested with previous experimental studies can be used for reaching generalized results and investigating parameters that are not studied. For this purpose, previous experimental study results are used and "T" cross-sectioned RC beams strengthened with CFRP strips with insufficient shear strength are modeled by using ANSYS software. First, finite elements modeling of the previously tested RC beams are done, and then the computed results are compared with the experimental ones whether they are matched or not. As a result, the finite element model is verified. Later, analyses of the cases without any test results are done by using the verified model. Optimum CFRP strip spacing is determined with this verified finite element model, and compared with the experimental findings.

Buckling behavior of pultruded composite beams with circular cutouts

  • Aktas, Mehmet;Balcioglu, H. Ersen
    • Steel and Composite Structures
    • /
    • 제17권4호
    • /
    • pp.359-370
    • /
    • 2014
  • In this experimental and numerical study, the effect of plate thickness, the diameter of circular cutout, the distance between circular cutouts and rowing orientation angle effect (${\theta}$) on the buckling load of E-glass/vinylester pultruded composite beams with single and double circular cutouts, were investigated. The composite beam having 2, 4, and 6 mm thicknesses was produced as [Mat/${\theta}$ /Mat/${\theta}$ /Mat] by using pultrusion technique. Seven different fiber angles as $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$, and $90^{\circ}$ were chosen for investigation of rowing orientation angle. The distances between each circular cutout were selected as 15, 30, 45, 60, and 75 mm in the case of double circular cutouts. The diameters of circular cutouts were chosen as 2, 4, 6, 8, and 10 mm to investigate the effect of cutout size. The experimental buckling loads were compared with the results calculated from the numerical analysis. ANSYS 11 commercial software was used for numerical study. A good agreement was obtained between numerical and experimental results.

Analysis of Airtightness and Air Leakage of Wooden Houses in Korea

  • Kim, Sejong;Chang, Yoon-Seong;Park, Joo-Saeng;Shim, Kug-Bo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권6호
    • /
    • pp.828-835
    • /
    • 2017
  • Airtightness of buildings is one of critical aspects of its energy performance. To build up references of airtightness of wooden houses built in Korea, blower door tests have been carried out in 42 houses since 2006. Causes of air leakage were investigated recently. The average value of air change rate was $3.7h^{-1}$ for light frame house and $5.5h^{-1}$ for post-beam construction at ACH50 (air change per hour at 50 Pa air pressure difference). Foam type insulation was more advantageous in ensuring building airtightness than glass fiber batt. Airtightness of wooden houses which were constructed after 2010 was improved to have less than $1.5h^{-1}$ of ACH50, threshold for application of artificial air change. The average air change rate of CLT (cross laminated timber) houses showed the lowest value, $1.1h^{-1}$, among the tested structures.

초고속 무선 광통신을 위한 송신광학계의 설계 (Design of optical transmitter system for high-speed wireless optical communication)

  • 권영훈;임천석
    • 한국광학회지
    • /
    • 제15권2호
    • /
    • pp.158-170
    • /
    • 2004
  • 유선 통신의 포화지역이나 도심에서 벗어난 인구밀도가 낮은 지역 둥에서 고속 광통신을 위해 최근 무선 광통신이 새롭게 기대되고 있다. 본 논문에서는 이러한 무선 광통신을 위한 송신 광학계를 설계하였는데, 광원으로는 수평(7$^{\circ}$)및 수직(18$^{\circ}$) 발산각이 다른 비대칭 타원형 빔을 발산하는 레이저 다이오드(중심 파장 830 nm)를 사용하였다. 제안되는 송신 광학계는 장거리 전송(500 m∼1500 m)이 가능하고, 장거리 전송 후 수신단에서 빔 직경(3 m) 및 에너지 분포가 대칭형이 되도록 설계되었다. 이를 위해 비결상 광학계인 송신 광학계의 평가법으로 에너지 전달 효율과 복사 조도 분포를 계산하였다.

Design and Simulation of Integral Twist Control for Helicopter Vibration Reduction

  • Shin, Sang-Joon;Cesnik Carlos E. S.;Hall Steven R.
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권1호
    • /
    • pp.24-34
    • /
    • 2007
  • Closed-loop active twist control of integral helicopter rotor blades is investigated in this paper for reducing hub vibration induced in forward flight. A four-bladed fully articulated integral twist-actuated rotor system has been designed and tested successfully in wind tunnel in open-loop actuation. The integral twist deformation of the blades is generated using active fiber composite actuators embedded in the composite blade construction. An analytical framework is developed to examine integrally twisted helicopter blades and their aeroelastic behavior during different flight conditions. This aeroelastic model stems from a three-dimensional electroelastic beam formulation with geometrical-exactness, and is coupled with finite-state dynamic inflow aerodynamics. A system identification methodology that assumes a linear periodic system is adopted to estimate the harmonic transfer function of the rotor system. A vibration minimizing controller is designed based on this result, which implements a classical disturbance rejection algorithm with some modifications. Using the established analytical framework, the closed-loop controller is numerically simulated and the hub vibratory load reduction capability is demonstrated.

Finite element analysis of shear critical prestressed SFRC beams

  • Thomas, Job;Ramaswamy, Ananth
    • Computers and Concrete
    • /
    • 제3권1호
    • /
    • pp.65-77
    • /
    • 2006
  • This study reports the details of the finite element analysis of eleven shear critical partially prestressed concrete T-beams having steel fibers over partial or full depth. Prestressed concrete T-beams having a shear span to depth ratio of 2.65 and 1.59 and failing in the shear have been analyzed using 'ANSYS'. The 'ANSYS' model accounts for the nonlinear phenomenon, such as, bond-slip of longitudinal reinforcements, post-cracking tensile stiffness of the concrete, stress transfer across the cracked blocks of the concrete and load sustenance through the bridging of steel fibers at crack interface. The concrete is modeled using 'SOLID65'-eight-node brick element, which is capable of simulating the cracking and crushing behavior of brittle materials. The reinforcements such as deformed bars, prestressing wires and steel fibers have been modeled discretely using 'LINK8' - 3D spar element. The slip between the reinforcement (rebar, fibers) and the concrete has been modeled using a 'COMBIN39'-non-linear spring element connecting the nodes of the 'LINK8' element representing the reinforcement and nodes of the 'SOLID65' elements representing the concrete. The 'ANSYS' model correctly predicted the diagonal tension failure and shear compression failure of prestressed concrete beams observed in the experiment. The capability of the model to capture the critical crack regions, loads and deflections for various types of shear failures in prestressed concrete beam has been illustrated.

시간 평균 ESPI를 이용한 진동 물체의 모우드 형태의 계측 (Measurement of Vibration Mode Shapes Using Time Average ESPI)

  • 강영준;최장섭
    • 한국정밀공학회지
    • /
    • 제13권2호
    • /
    • pp.84-93
    • /
    • 1996
  • Non-destructive inspection techniques using laser have been broading their application areas as well as growing their measurement skills together with the rapid development of circumferential technology like fiber optics, computer and image processing. The ESPI technique is already on the stage of on-line testing with commercial products in developed country nations. Especially, this technique is expected to be applied to the nuclear industry, automobile and aerospace because it is proper for the vibration measurement and it can be applied to objects of a high temperature. This paper describes the use of the ESPI system for measuring vibration patterns on the reflecting objects. Using this system, high-quality Jo fringes for identifying mode shapes are displayed. A bias vibration is introduced into the reference beam to shift the Jo fringes so that fringe shift algorithms can be used to determine vibration amplitude. Using this method, amplitude fields for vibrating objects were obtained directly from the time-average interferograms recorded by the ESPI system.

  • PDF