• Title/Summary/Keyword: fertility evaluation

Search Result 102, Processing Time 0.023 seconds

Evaluation of lines of NERICA 1 introgressed with Gn1a and WFP for yield and yield components as affected by nitrogen fertilization in Kenya

  • Makihara, Daigo;Samejima, Hiroaki;Kikuta, Mayumi;Kimani, John M.;Ashikari, Motoyuki;Angeles-Shim, Rosalyn;Sunohara, Hidehiko;Jena, Kshirod K.;Yamauchi, Akira;Doi, Kazuyuki
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.323-323
    • /
    • 2017
  • In many sub-Saharan African countries, boosting rice production is a pressing food security issue. To contribute to the increase in rice production, we have developed lines of NERICA 1 introgressed with the gene for spikelet number, Gn1a, and the gene for primary rachis-branch number, WFP by cross breeding. The performance of rice lines introgressed with the genes for yield related traits can be affected by cultivation environment and management. Thus, in this study, we aimed to evaluate the lines of NERICA 1 introgressed with Gn1a or/and WFP for yield and yield components under different nitrogen fertilization conditions in Kenya. A field trial was conducted at a paddy field in Kenya Agricultural and Livestock Research Organization-Mwea, Kirinyaga County ($0^{\circ}39^{\prime}S$, $0^{\circ}20^{\prime}E$) from August 2016 to January 2017. Eight lines of NERICA 1 introgressed with Gn1a and/or WFP, and their parents, NERICA 1 and ST12, were grown under 0 (NF) and $75(SF)kg\;N\;ha^{-1}$. At maturity, five hills per plot were harvested to determine the yield and yield components. The number of primary and secondary rachis-branches per panicle was measured on the longest panicle in each hill. Under SF, the introgression of WFP to NERICA 1 increased the number of primary and secondary rachis-branches by 27 and 25%, respectively. On the other hand, Gn1a did not increase the number of primary rachis-branches, whereas the number of secondary rachis-branches was increased by 38% on average. The number of primary and secondary rachis-branches of the lines introgressed with both genes increased by 25 and 56%, respectively. Although grain number per panicle increased 33% by Gn1a, 34% by WFP, and 43% by Gn1a+WFP, the yield increase by Gn1a, WFP, and Gn1a+WFP was only 14, 7, and 14%, respectively. The suppression of the yield increase was mainly attributed to the decline in the filled grain ratio. Under NF, WFP increased the number of primary and secondary rachis-branches by 20 and 19%, respectively. The introgression of both genes increased the former and the later by 19 and 35%, respectively. However, Gn1a did not change them under NF. Thus, even under NF, grain yield increased 11% by WFP and 24% by Gn1a+WFP due to the increased grain number although filled grain ratio declined. Our findings suggest that the introgression of Gn1a and WFP could contribute to the rice productivity improvement in sub-Saharan Africa even under low fertility conditions. Improving filled grain ratio of the lines introgressed with these genes by further breeding and fertilization management will be the focus of subsequent work.

  • PDF

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.