• 제목/요약/키워드: femur head height difference

검색결과 3건 처리시간 0.016초

골반변위와 대퇴골두 높이차이에 대한 상관성 비교 - Gonstead's Technique을 중심으로 - (Ananlysis of Correlation between Functional Leg Length Discrepancy caused by Pelvic tilting and Femur head height difference)

  • 이경윤;서진우;박쾌환;박민정
    • 대한추나의학회지
    • /
    • 제5권1호
    • /
    • pp.213-222
    • /
    • 2004
  • Objectives : To investigate contributing degree of other factors except pelvic tilting to F.L.L.D by analizing with Gonstead technique on the correlation between femur head height discrepancy on the standing pelvic AP view and F.L.L.D caused by pelvic tilting. Method : We analysed standing pelvis AP X-ray of 70 patients who had visited at the department acupunture and moxibustion in Conmaul oriental medical hospital, during May, 1st, 2004 - July, 30th, 2004, with low back pain or lower extremity pain. We excluded the person with any past history of polio, genetic defect, malunited fracture, growth plate injury, infection and overgrowth attributable to hemangioma, or arteriovenous fistula. Results & Conclusion : The functional leg length discrepancy caused by pelvic tilting and femur head height difference had no statistical difference(p=0.132) but poorly correlated(Pearson ${\nu}=0.05$). In the 94.28% of subjects, the femur head height difference wasn't in accord with F.L.L.D. caused by pelvic tilting. In 47.14% of subjects were expected to have over $3^{mm}$ of leg length discrepancy after pelvic adjustment. The mean of measurement difference between two methods was $3.76{\pm}3.12^{mm}$ and the range was $0{\sim}11.4^{mm}$. Consequently, we must consider not only functional leg length discrepancy caused by pelvic tilting but also anatomical leg length discrepancy, misalignment of ankle, knee or hip joint etc.

  • PDF

골반 변위가 있는 환자에서 추나 치료군과 자가 MET 병행군의 교정 정도 비교 연구 : 무작위 대조 연구 (The comparative study between the effect of Chuna manual treatment and Chuna manual treatment with self muscle energy techniques on patients with pelvic malposition : A Randomized, Controlled, Trial)

  • 윤용일;허석원;배영춘;정범환;조주현
    • 척추신경추나의학회지
    • /
    • 제10권1호
    • /
    • pp.75-86
    • /
    • 2015
  • Objectives : The purpose of this study is to compare the effect of Chuna manual treatment and Chuna manual treatment with self muscle energy techniques on patients with pelvic malposition Methods : Random allocation was done. We used Chuna manual treatment to control group and Chuna manual treatment with self muscle energy techniques to experimental group. These patient's pelvic malposition were checked by Leg length analysis, measuring Innominate measurement length, obturator foramen size and height of femur head. Results : 1)After the 3 weeks treatment, patients' inequality of leg length and Innominate measurement length were significantly reduced. 2)There was no significant difference between control group and experimental group. Conclusions : Chuna manual treatment and Chuna manual treatment with self muscle energy techniques are considered to be effective and useful in patients with pelvic malposition. But there was no significant difference between control group and experimental group.

이중 에너지 X선 흡수 계측법을 이용한 BMD 검사 시 발생할 수 있는 기술적인 오류 분석 (The Study of Technical Error Analysis on BMD Using DEXA)

  • 강영한;조광호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.229-236
    • /
    • 2006
  • 연구목적: 이중 에너지 X선 흡수 계측법(DEXA, dual-energy X-ray absorptiometry)을 이용한 골다공증 진단 시 발생할 수 있는 기술적인 오류의 유형을 분석하고, 골밀도(BMD, bone mineral density) 값에 미치는 영향에 대해 알아보고자 실시하였다. 연구대상 및 방법: 환자 정보(연령, 체중, 신장, 폐경연령) 입력 오류와 관심영역(ROI, region of interest) 설정에 대한 오류로 나누어 연구하였다. 환자정보 입력 오류는 연령과 폐경연령을 5살, 10살 많게 또는 적게 입력하고, 신장과 체중도 동일한 조건으로 증감하며 입력하여 척추팬텀으로 각각 10회씩 스캔하였다. ROI 설정 오류는 폐경기 여성 10명을 대상으로 스캔을 실시하여 요추부, 고관절부, 전완으로 나누어 ROI를 변화시키며 $BMD(g/cm^2)$, T-score 값을 얻었고, 각각의 결과 값으로 정밀도 1%를 적용하여 평균에 대한 차이 분석을 실시하였다. 결 과: 연령과 신장, 체중 폐경연령에 대한 환자 정보 입력 오류는 정밀도 1%에서 유의하지 않게 나타났다. ROI 설정 오류는 요추부 ROI 설정 시 ROI 기준선을 좌우 1 cm, 2 cm 좁혔을 때 평균 $0.006\;g/cm^2$, 0.1 그리고 $0.021\;g/cm^2$, 0.15 감소하였다. 제 12흉추를 포함하였을 때 $BMD(g/cm^2)$와 T-score는 평균 $0.063\;g/cm^2$, 0.3 감소하였고, 제 5번 요추를 포함하였을 때 각각 $0.077\;g/cm^2$, 0.5 증가하였다. 고관절 관심영역을 대퇴골두 위쪽 또는 좌측으로 0.5 cm 이동하였을 때의 결과 값은 평균에 대한 차이를 보이지 않았다. 하지만 소전자 아래쪽 0.5 cm, 1 cm 이동하였을 때의 $BMD(g/cm^2)$와 T-score는 $0.031\;g/cm^2$, 0.3 그리고 $0.094\;g/cm^2$, 0.65로 증가하였다. 전완의 관심영역을 수근부 아래쪽, 위쪽으로 1 cm으로 이동하였을 때 $BMD(g/cm^2)$와 T-score는 $0.042\;g/cm^2$, 0.9 감소 또는 $0.096\;g/cm^2$, 0.40 증가하였다. 좌우 기준선이 1 cm, 2 cm 넓어질 때 $BMD(g/cm^2)$, T-Score는 평균 $0.008\;g/cm^2$, 0.1 증가 또는 $0.021\;g/cm^2$, 0.3으로 증가하였다. 결 론: 골밀도 측정 시 발생할 수 있는 기술적인 오류는 다양하며, 오류에 따라 정상 BMD 값과 T-score에 변동이 있음을 알 수 있었다. 환자정보 입력과정에 발생할 수 있는 연령과 체중, 신장, 폐경 연령에 따른 입력오류는 BMD와 T-score에 영향을 미치지 않았으나 일반적 골밀도 검사 시에는 중요한 요소이다. ROI 지정 오류 시에는 BMD 값과 T-score에 유의한 차이가 있었다. 정확한 골밀도 검사를 위해서는 환자 정보에 대해서도 자세한 파악이 있어야 하겠지만 검사자의 기술적 지식이 결과 값에 영향을 미치게 됨을 충분히 인지하고 검사에 임하여야 하겠다.

  • PDF