• Title/Summary/Keyword: femur fracture

Search Result 192, Processing Time 0.026 seconds

Treatment of Reverse Oblique Trochanteric Fracture with Compression Hip Screw (대퇴골 전자부 역사상 골절의 압박고 나사를 이용한 치료)

  • Kim, Dong-Hui;Lee, Sang-Hong;Ha, Sang-Ho;You, Jae-Won
    • Journal of Trauma and Injury
    • /
    • v.23 no.1
    • /
    • pp.1-5
    • /
    • 2010
  • Purpose: To investigate the results of treatment of reverse oblique trochanteric fractures with compression hip screw. Methods: We reviewed the results of 12 cases of reverse oblique trochanteric fracture treated with compression hip screw from January 2000 to December 2006 which could be followed up for more than 1 year. The mean follow up period was 26 months (15~40). The mean age was 48 years old. Injury mechanism was composed of 6 cases of traffic accident and 6 cases of fall down. 8 persons were man. We investigated the union time, degree of neck-shaft angle change, amount of sliding of compression hip screw, complications, functional and clinical results. Results: 10 cases were united and the mean union time were 5 months (3~8). The mean neck-shaft angle change was 3.5 degrees (0~12). The amount of sliding of compression hip screw was 8.9 mm (2~24). There were six coxa vara, six leg due to coxa vara shortening, two nonunion, and one superficial infection. Unsatisfactory results of Jensen's social function score and Parker and Palmer's mobility score were studied. Conclusion: The results of treatment of reverse oblique trochanteric fractures with compression hip screw were relatively unsatisfied.

Rare Imaging of Fat Embolism Seen on Computed Tomography in the Common Iliac Vein after Polytrauma

  • Lee, Hojun;Moon, Jonghwan;Kwon, Junsik;Lee, John Cook-Jong
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.103-106
    • /
    • 2018
  • Fat embolism refers to the presence of fat droplets within the peripheral and lung microcirculation with or without clinical sequelae. However, early diagnosis of fat embolism is very difficult because the embolism usually does not show at the computed tomography as a large fat complex within vessels. Forty-eight-year-old male with pedestrian traffic accident ransferred from a local hospital by helicopter to the regional trauma center by two flight surgeons on board. At the rendezvous point, he had suffered with dyspnea without any airway obstruction sign with 90% of oxygen saturation from pulse oximetry with giving 15 L of oxygen by a reserve bag mask. The patient was intubated at the rendezvous point. The secondary survey of the patient revealed multiple pelvic bone fracture with sacrum fracture, right femur shaft fracture and right tibia head fracture. Abdominal computed tomography was performed in 191 minutes after the injury and fat embolism with Hounsfield unit of -86 in his right common iliac vein was identified. Here is a very rare case that mass of fat embolism was shown within common iliac vein detected in computed tomography. Early detection of the fat embolus and early stabilization of the fractures are essential to the prevention of sequelae such as cerebral fat embolism.

The Effect on the Hip Muscle Activation of the Fall Direction and Knee Position During a Fall

  • Lee, Kwang Jun;Lim, Kitaek;Choi, Woochol Joseph
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.84-91
    • /
    • 2021
  • Background: A hip fracture may occur spontaneously prior to the hip impact, due to the muscle pulling force exceeding the strength of the femur. Objects: We conducted falling experiments with humans to measure the activity of the hip muscles, and to examine how this was affected by the fall type. Methods: Eighteen individuals fell and landed sideways on a mat, by mimicking video-captured real-life older adults' falls. Falling trials were acquired with three fall directions: forward, backward, or sideways, and with three knee positions at the time of hip impact, where the landing side knee was free of constraint, or contacted the mat or the contralateral knee. During falls, the activities of the iliopsoas (Ilio), gluteus medius (Gmed), gluteus maximus (Gmax) and adductor longus (ADDL) muscles were recorded. Outcome variables included the time to onset, activity at the time of hip impact, and timing of the peak activity with respect to the time of hip impact. Results: For Ilio, Gmed, Gmax, and ADDL, respectively, EMG onset averaged 292, 304, 350, and 248 ms after fall initiation. Timing of the peak activity averaged 106, 96, 84, and 180 ms prior to the hip impact, and activity at the time of hip impact averaged 72.3, 45.2, 64.3, and 63.4% of the peak activity. Furthermore, the outcome variables were associated with fall direction and/or knee position in all but the iliopsoas muscle. Conclusion: Our results provide insights on the hip muscle activation during a fall, which may help to understand the potential injury mechanism of the spontaneous hip fracture.

Pathologic Fracture of Unicameral Bone Cyst (단순 골낭종에서 발생한 병적 골절)

  • Choo, Suk-Kyu;Lee, Hee-Du;Oh, Hyoung-Keun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.2
    • /
    • pp.58-64
    • /
    • 2011
  • Purpose: The purpose of this study is to observe unicameral bone cyst (UBC) outcome after the fracture has healed and if there is any identifiable prognostic factors. Materials and Methods: 13 UBC patients with pathologic fracture from 2001 to 2010 were reviewed. The mean follow up were 26 months (3-90 months). There were 11 male and 2 female patients and the mean age of the patients were 10.2 years old (6-16 years). 9 involved proximal humerusand 2 involved humerus shaft and 1 involved proximal femur and 1 involved proximal tibia. The treatment of UBC fracture was conservative cast application to heal the fracture initially, and 1 patient was treated with primary auto bone graft and open reduction with internal fixation. 5 patients were treated with steroid injection during follow up period and 2 patients with auto bone graft. We analyzed the change of UBC during pathologic fracture healing period and prognostic factor about age, the size of UBC, the involvement of physis. Results: The mean duration of the fracture healing was 8.2 months. Complete healing were occurred at 4 patients (31%). No statiscal difference was checked with age about UBC healing (p=0.42). But, more larger size about UBC and more closer to physis, the healing was difficult (p=0.05, p=0.03). Conclusion: While pathologic fracture of UBC was possibly healed, active treatment should be applied especially those cysts that involvescloser area of the physis or large size.

Fracture analysis of wild mammals in South Korea

  • Jang, Hyunkyu;Park, Jong-Moon;Ahmed, Sohail;Seok, Seong-Hoon;Kim, Ho-Su;Yeon, Seong-Chan
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.4
    • /
    • pp.175-180
    • /
    • 2019
  • This study was conducted to evaluate and analyze fractures types in wild mammals in Korea. Wild mammals treated at 3 wildlife centers in Korea were included. Of the 63 cases included in this study, water deer was the most common species encountered with fractures. We determined 85 different fracture sites, with maximum lumber vertebral fractures followed by femoral, tibial and pelvic fractures. External skeletal fixator (ESF)-intramedullary (IM) pin (IM+ESF tie-in fixation) was the most common method applied for the surgical treatment of mammals. Lumbar vertebrae and femur were the most common bones involved. The findings of this study are expected to provide information for veterinarians regarding the frequency and characteristics of fractures in wild mammals and serve as a basic database for the types and outcomes of fractures in wild mammals.

Numerical Stress Analysis of bone plate System using 3-dimensional finite element method (3차원 유한 요소법을 이용한 골절판의 응력 해석)

  • Kim, Hyun-Su;Kwon, Young-Soo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.74-78
    • /
    • 1991
  • Conventional compression bone fracture plates sometimes cause osteoporosis under the plate due to their high rigidity which in turn transfer physiological load mostly through the plates and screws. In order to prevent the osteopenia we have designed a system which have a viscoelastic washer between plate and screw head. The washer is made of a biocompatible ploymer (untra high molecular weight polyethylene, UHMWPE). Three-dimensional finite element meshes of the human femur with the conventional and new concept bone plate ere generated and the comparative stress analyses are performed with static half-stance loading condition. The results of analyses showed that could reduce the stress shielding effect compared with the conventional plate.

  • PDF

Biomechanical Finite Element Analysis of Bone Cemented Hip Crack Initiation According to Stem Design

  • Kim, Byeong-Soo;Moon, Byung-Young;Park, Jung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2168-2177
    • /
    • 2006
  • The purpose of this investigation was to determine the specific fracture mechanics response of cracks that initiate at the stem-cement interface and propagate into the cement mantle. Two-dimensional finite element models of idealized stem-cement-bone cross-sections from the proximal femur were developed for this study. Two general stem types were considered; Rectangular shape and Charnley type stem designs. The FE results showed that the highest principal stress in the cement mantle for each case occurred in the upper left and lower right regions adjacent to the stem-cement interface. There was also a general decrease in maximum tensile stress with increasing cement mantle thickness for both Rectangular and Charnley-type stem designs. The cement thickness is found to be one of the important fatigue failure parameters which affect the longevity of cemented femoral components, in which the thinner cement was significantly associated with early mechanical failure for shot-time period.

Kupffer Cells Are Responsible for Producing Hepatic Microsomal Drug Metabolizing Dysfunction during Trauma and Sepsis

  • Lee, Sang-Ho;Kim, Joo-Young;Kim, Sung-Ho;Eum, Hyun-Ae;Lee, Sun-Mee
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.301.3-302
    • /
    • 2002
  • Sepsis remains the leading cause of morbidity and mortality following trauma. Although hepatocellular dysfunction occurs during trauma and sepsis. the mechanism responsible for this remains unclear. We investigated the role of Kupffer cells in the alterations in microsomal drug metabolizing function during trauma and sepsis. Rats were subjected to trauma by femur fracture (FFx). After 72h, polymicrobial sepsis was induced by cecal ligation and puncture(CLP). (omitted)

  • PDF

A Prototype of Robotic External Fixation System for Surgery of Bone Deformity Correction

  • Kim, Yoon-Hyuk;Joo, Sang-Min;Lee, Soon-Geul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2448-2450
    • /
    • 2005
  • A robotic external fixation system for the surgery of bone deformity correction was developed to simulate the execution process of mal-unioned femur by the adjustment of the joints of the fixation system. An inverse kinematics analysis algorithm was developed to calculate the necessary rotations and translations at each joint of the robotic system. The computer graphic model was developed for validation of the analysis result and visualization of the surgical process. For given rotational and angular deformity case, the surgical execution process using the robotic system was well matched with the pre-operative planning. The final residual rotational deformities were within $1.0^{\circ}{\sim}1.6^{\circ}$ after surgical correction process. The presented robotic system with computer-aided planning can be useful for knowledge-based fracture treatment and bone deformity correction under external fixation.

  • PDF

Development of Computer-Aided Surgery System for High Tibial Osteotomy Using Tracking-Pin and Fluoroscopic G-arm Images (Tracking-Pin과 Fluoroscopic G-arm 이미지를 이용한 경골근위부절골술 지원시스템 개발)

  • Koo, Bon-Yeol;Kim, Cheol-Woong;Lee, Sun-Hyuk;Bae, Ji-Hoon;Park, Cheol-Woo;Kim, Jay-Jung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.5
    • /
    • pp.331-343
    • /
    • 2011
  • High tibial osteotomy (HTO) is a widely accepted treatment for unicompartmental osteoarthritis of the knee and other lower extremity deformities, particularly for young and active patients. However, it is generally recognized as a technically demanding procedure. Thus the limitations of conventional surgical methods have been reported. Currently, the use of computer-aided surgery (CAS) system for successful surgery was increased. However it has been reported many problems such as expensive equipment, infection or fracture caused by inserting half-pin and delaying surgery. Therefore we propose a novel method which can be tracked by using tracking-pin inserted in arbitrary locations of the femur and tibia, and fluoroscopic images obtained from G-arm of antero-posterior and lateral-medial.