• Title/Summary/Keyword: feeder network

Search Result 109, Processing Time 0.032 seconds

A Study for the Improvement of Fault Detection on Fault Indicator using DWT and Neural Network (신경회로망과 DWT를 이용한 고장표시기의 고장검출 개선에 관한 연구)

  • Hong, Dae-Seung;Yim, Hwa-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.46-48
    • /
    • 2007
  • This paper presents research about improvement of fault detection algorithm in FRTU on the feeder of distribution system. FRTU(Feeder Remote Terminal Unit) is applied to fault detection schemes for phase fault, ground fault, and cold load pickup and Inrush restraint functions distinguish the fault current and the normal load current. FRTU is occurred FI(Fault Indicator) when current is over pick-up value also inrush current is occurred FRTU indicate FI. Discrete wavelet transform(DWT) analysis gives the frequency and time-scale information. The neural network system as a fault detector was trained to discriminate inrush current from the fault status by a gradient descent method. In this paper, fault detection is improved using voltage monitoring system with DWT and neural network. These data were measured in actual 22.9kV distribution system.

  • PDF

Development of intelligent coagulant feeding system (지능형 응집제 투입 시스템의 개발)

  • Chung, Woo-Seop;Oh, Sueg-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.652-658
    • /
    • 1997
  • Coagulant feeding control is very important in the water treatment process. Coagulant feeding is related to the raw water quality such as turbidity, alkalinity, water temperature, pH and so on. However, since the process of chemical reaction has not been clarified so far, coagulant dosing rate has been decided by jar-test. In order to overcome the difficulty mentioned above, Fuzzy Neural Network to fuse fuzzy logic and neural network was proposed, and the scheme was applied to the automatic determination of coagulant dosing rate. This algorithm can automatically identify the if-then rules, tune the membership functions by utilizing expert's experimental data. The proposed scheme is evaluated by computer simulation and interfaced with coagulant feeder operated by magnetic flowmeter, control valve and PLC. It is shown that coagulant feeding according to real time sensing of water quality is very effective.

  • PDF

A FEEDER CONTROL FOR THE SMT MOUNTER USING LON CHIP

  • Lim Eung-Kyu;Rho Sung-Chan;Kim Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.121-125
    • /
    • 2001
  • SMD mounter is necessary in PCB assembling line. To feed SMD components to the mounter, high performance feeders are needed. Until now, mechanical air feeders have been mainly used. However, in these days, electrical feeders with network are developed. There are many kinds of feeders with various control techniques. In this paper, a feeder with BLDC motor and LON chip is designed and implemented. And, the experimental results are presented.

  • PDF

A Study on the Electromagnetic Modeling and Network Analysis for GTEM Cell Design (GTEM 셀 설계를 위한 전자파 모델링 및 회로망 해석 기법 연구)

  • Lee, Woo-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.7
    • /
    • pp.791-799
    • /
    • 2008
  • In this paper, the electromagnetic modeling and network analysis are proposed for design of GTEM cell operating from DC to 18 GHz. 3D electromagnetic numerical analysis models composed of the coaxial mode-converter for the feeder of GTEM cell, 5 m expanded rectangular coaxial transmission line, and the resistive termination load for current and field transmitted from the feeder are developed. Equivalent network model of feeder, transmission line, and termination load in the GTEM cell is also proposed, so the return loss of GTEM cell is calculated using S-parameters using the electromagnetic numerical analysis. To verify the proposed design method, the GTEM cell is designed, constructed and tested, with its size of $5{\times}2.5{\times}1.7\;m$ and operating frequency of $DC{\sim}18\;GHz$.

A Study on the Improvement of Fault Detection Capability for Fault Indicator using Fuzzy Clustering and Neural Network (퍼지클러스터링 기법과 신경회로망을 이용한 고장표시기의 고장검출 능력 개선에 관한 연구)

  • Hong, Dae-Seung;Yim, Hwa-Young
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.3
    • /
    • pp.374-379
    • /
    • 2007
  • This paper focuses on the improvement of fault detection algorithm in FRTU(feeder remote terminal unit) on the feeder of distribution power system. FRTU is applied to fault detection schemes for phase fault and ground fault. Especially, cold load pickup and inrush restraint functions distinguish the fault current from the normal load current. FRTU shows FI(Fault Indicator) when the fault current is over pickup value or inrush current. STFT(Short Time Fourier Transform) analysis provides the frequency and time Information. FCM(Fuzzy C-Mean clustering) algorithm extracts characteristics of harmonics. The neural network system as a fault detector was trained to distinguish the inruih current from the fault status by a gradient descent method. In this paper, fault detection is improved by using FCM and neural network. The result data were measured in actual 22.9kV distribution power system.

LAN-Based Protective Relaying for Interconnect Protection of Dispersed Generators (LAN을 이용한 분산전원 연계 계통의 보호)

  • Jyung, Tae-Young;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.491-497
    • /
    • 2007
  • As dispersed generators was driven in condition interconnecting with utility, it could cause a variety of new effects to the original distribution system that was running as considered only the one-way power flow. Therefore, the protection devices that is builted in distribution system should be designed to be able to operate with disposing of not only a fault of the generator, but also utility condition. Especially, the fault of the feeder interconnected with Dispersed Generator can cause the islanding phenomenon of open DG(Dispersed Generators). This phenomenon has many problems such as a machinery damage, electricity qualify degradation and a difficulty of the system recovery. In the fault therefore, we must separate Dispersed Generator from the system quickly. In this paper, for the fault classification of the interconnected DG and the outside feeder we judge the fault of the interconnected DG and the outside feeder in HMI through data provided by IED(Intelligent Electronic Device) on the network and decide whether it operates or not by sending the result to each relay.

Distribution Network Switching Automation Using Active Web Based Management

  • Choi, Sang-Yule
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.81-86
    • /
    • 2007
  • Electric utility companies have the responsibility of providing good electricity for their customers. They have introduced the DAS(Distribution Automation System) to automate the power distribution networks. DAS engineers require state-of-the-art applications, such as a way to actively manage the distribution system and gain economic benefits from a flexible DAS architectural design. The existing DAS is not capable of handling these needs. It requires operator intervention whenever feeder overloading is detected while operator error could cause the feeder overload area to be extended. It also utilizes a closed architecture and it is therefore difficult to meet the system migration and future enhancement requirements. This paper represents a web based, platform-independent, flexible DAS architectural design and active database application. Recent advanced Internet technologies are fully utilized in this new DAS architecture allowing it to meet the system migration and future enhancement requirements. By using an active database, the DAS can minimize the feeder overloading area in the distribution system without operator intervention, thereby minimizing mistakes due to operator error.

NETWORK RECONFIGURATION ALGORITHM FOR AUTOMATED DISTRIBUTION SYSTEM BASED ON THE BEST-FIRST TREE SEARCH (경험적 탐색기법에 근거한 배전계통의 선로 재구성 앨고리즘)

  • Jung, Kyung-Hee;Kim, Ho-Yong;Ko, Yun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.350-353
    • /
    • 1991
  • This study develops an expert system which solves the problems of the MTr/feeder overloads and the feeder constraints in automated radial distribution systems. Then, the objective is to perform the network reconfiguration by switching the tie and sectionalizing switches which eliminates the system violation, while achieving the load balance of the MTrs/feeders. To reduce the search space, an expert system based on heuristic rules is presented, and implemented in AI language Prolog. This system adopts the best-first tree search technique. The computational results are also prepared to show the performance of the heuristic algorithm developed.

  • PDF

A Study on the Bus Operation Management and Transport Strategy (버스운행관리 및 수송전략에 관한 연구)

    • Journal of Korean Port Research
    • /
    • v.13 no.2
    • /
    • pp.323-332
    • /
    • 1999
  • The bus should supply an equal service to the whole community as feeder trip. However the existing bus route can not supply an effective feeder service in spite of the changes in the latent demand by the variety of regional structural change. This study aimed to establish the concept which frames the bus operation and management to cope with the latent demand to the bus. This study tackled this evidence by analyzing the transportation problems in terms of the urban growth emphasizing the following issues ; First, the strategy to improve the bus operation Second the land use control appropriate for the public transportation network Third economical range to justify the bus operation Second, the land use control appropriate for the public transportation network Third, economical range to justify the bus operation Fourth, the allowance for the private transportation mode On the latter part, the difference on the bus operation was compared to determine the range within which the bus operation could be justified. This study would provide some implications to improve the management for bus operation and fundamental information to develop the bus operation system.

  • PDF

A Study on the Voltage/Var Control of Distribution System Using Kohonen Neural Network (코호넬 신경회로망을 이용한 배전시스템의 전압/무효전력 제어게 관한 연구)

  • Kim, Gwang-Won;Kim, Jong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.329-331
    • /
    • 1998
  • This paper presents a modified Learning Vector Quantization rule to control shunt capacitor banks and feeder voltage regulators in electric distribution systems with Kohonen Neural Network(KNN). The objective of the KNN is on-line decision of the optimal state of shunt capacitor banks and feeder voltage regulators which minimize $I^{2}R$ losses of the distribution system while maintaining all the bus voltages within the limits. The KNN is tested on a distribution system with 30 buses, 5 on-off switchable capacitor banks and a nine tap line voltage regulator.

  • PDF