• Title/Summary/Keyword: feeder line

Search Result 182, Processing Time 0.029 seconds

Analysis of Improvement Method of Isolation Between Digital Noise and the Mobile Handset Antenna Title (디지털 노이즈와 휴대단말 안테나의 격리도 향상 방법 분석)

  • Kim, Joonchul
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.474-478
    • /
    • 2019
  • In this paper, we analyze the degradation of receiving sensitivity due to the coupling between digital noise and mobile handset antenna using characteristic mode. First, we analyze the coupling mechanism between the antenna and digital noise, and analyze the role of the decoupling capacitor of the ground signal line, which is one of the ways to improve the antenna receiving sensitivity degradation due to camera noise. For the analysis, the digital signal line and the ground line of the FPCB of the camera module are modeled as a loop type feeder that excites the characteristic mode of the PCB ground, and improved model which has a ground line with a capacitor are analyzed.

The Development of Application Programs for Optimal Feeder Operation Through Distribution Automatic System

  • Ha, Bok-Nam;Seol, Ieel-Ho;Jeong, Mi-Ae
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.42-47
    • /
    • 2004
  • This paper presents the various application programs for the Distribution Automation System (DAS) of the Korea Electric Power Corporation (KEPCO)'s distribution system. These programs are developed to allow for optimal operation in the areas of feeder automation, relay coordination, loss minimization and so on. They are single line diagram auto creation programs for the feeder, service restoration program, protection coordination program, data error detection program, and optimal network reconfiguration program. The details of these programs are presented for validity and effectiveness.

High Efficiency Ozone Generation Using a Pyramid-Project-Embossed Rod-to-Cylinder Electrode and a Pulse Corona Discharge (도깨비봉형 오존발생장치이 펄스커로나 방전에 의한 오존 발생 특성)

  • 문재덕;이근택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.650-657
    • /
    • 1989
  • The conversion efficiency of an ozone generator can be significantly improved by modifying the discharge electrode of a helical strip line rod-to-cylinder type ozone generator to a pyramid-project-embossed rod, and by using a pulse corona discharge. Parametric studies have been carried out to obtain optimum values of peak pulse voltage, pulse forming capacitance, feeder cable and ozone generator capacitance, interelectrode spacing and corona tip density of ozone generator, and feed air flow rate and temperature. The generated ozone concentration was very dependent upon the value of pulse forming capacitance, feeder cable and ozone generator capacitance, and corona tip density. Maximum conversion efficiency was obtained with a pulse forming capacitance of about 500pF, 75pF matched feeder cable and ozone generator, and a corona tip density of 16mm. When operated at optimum values, ozone yield of 79, 99, 80 g/KWh for the different interelectrode type ozone generators tested were obtained, which are approximately 30% higher than that of an industrial ozone generator.

  • PDF

Economic Evaluation far the Application of the Distribution Automation System (배전자동화시스템 적용을 위한 경제성 평가)

  • Hong, Soon-Hak;Ha, Bok-Nam;Kim, Ho-Yong;Jung, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.36-38
    • /
    • 1993
  • This study considers the economic aspect of the distribution automation system, which is the decision-making criteria of the electric utilities for the investment. The feeder automation candidate region is divided into two types of the urban and the rural. The total investment cost of the feeder automation for each type is estimated. The annual cost, is also estimated, by finding the fixed charge rate. To compare the annual cost and the economic effect cost, for the investment decision-making, the costs are quantitatively estimated on the following effects : the manpower replacement, the outage cost saving, the main transformer utilization improvement, the feeder utilization improvement, and the line loss reduction.

  • PDF

IPI feeding structure for the gain improvement of IFA (IFA 이득 향상을 위한 IPI 급전 구조)

  • Oh, Kyu-Jong;Son, Tae-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.817-823
    • /
    • 2010
  • Design of IPI feeding structure affecting the antenna gain improvement of mobile phone was investigated. IPI feeder which based on the T matching theory increase line current for internal antenna such as IFA. So IPI feeder makes higher radiation resistance, and also increases the gain with increasing radiation efficiency. To verify IPI feeding effect, feeder is applied to conventional CDMA/DCS dual band IFA. Measurement shows that IPI-IFA has 0.5 ~ 1.4[dBi] higher gain than conventional IFA at CDMA/DCS band. Resonant frequency did not change.

Development of the Process Planning Program for a Multi-functional Surface Mounting Device (다기능 표면실장기의 공정계획 프로그램 개발)

  • Sohn, Jin-Hyeon;Yu, Sung-Yeol;Kang, Jang-Ha;Park, Sung-Soo;Oh, Byung-Jun;Seong, Pil-Young
    • IE interfaces
    • /
    • v.10 no.1
    • /
    • pp.155-167
    • /
    • 1997
  • The purpose of this study is to develop the program for efficient operation of a multi-functional surface mounting device(SMD) which mount various components on a printed circuit board(PCB). These components are provided by diverse types of feeders such as cassette, stick and tray feeders. The SMD has one or two heads. In the SMD, the positions of PCB and feeders and fixed, and the head moves to pick up a component from a feeder and to mount it on the PCB. The number of lanes occupied by each feeder and the nozzle used for each component can be different. We develop an off-line program to minimize the cycle-time of the SMD by studying the optimal assignment of feeders and the optimal mounting sequence of components. Graphical User Interface(GUI) is also developed. Additionally, we consider the line balancing problem which appears when two SMDs are used sequentially.

  • PDF

A study on the Safety of metro-railroad electric power feed system (도시철도 전력 급전시스템에 대한 안전성 연구)

  • Lee, Bong-Jae;Park, Weon-Chan;Kim, Woo-Seob;Jeong, Seong-Yeong
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.390-398
    • /
    • 2008
  • While road traffic of sharp rise of an international oil price and capital Seoul reaches to critical point, and a use passenger drives recklessly on the subway which is a cradle of public transportation, the depths analyzes an electric power feed system regarding a ground wealth electric car line of the subway Line 2 East Section which is a long distance (Seongsu $\sim$ Gangbyeon), and future, electric power supply Feeder Distribution Center prepares to Operational Headway shortening along an ATO signal method change by feeder increase supplement, and ensure safety to an electric power supply system, and will solve inconvenience of safe operation and use passenger.

  • PDF

A Study on Ground Fault Detecting System for DC Voltage Line in the Electric Power Plant (발전소 직류전압 전선로 접지검출시스템에 관한 연구)

  • Lee, H.K.;Kim, N.H.;Park, C.H.;Kim, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.754-757
    • /
    • 1995
  • This system can detect a ground fault point or a bad insulated line by measuring a power plant DC feeder insulation resistance at the uninterruptible power status. And when the power plant DC feeder with low frequency AC signal has a ground fault, this measuring system can keep recording of its ground fault current and phase checked by Z.C.T. Therefore the power plant could protect a unexpected service interruption.

  • PDF

A Study on the Voltage/Var Control of Distribution System Using Kohonen Neural Network (코호넬 신경회로망을 이용한 배전시스템의 전압/무효전력 제어게 관한 연구)

  • Kim, Gwang-Won;Kim, Jong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.329-331
    • /
    • 1998
  • This paper presents a modified Learning Vector Quantization rule to control shunt capacitor banks and feeder voltage regulators in electric distribution systems with Kohonen Neural Network(KNN). The objective of the KNN is on-line decision of the optimal state of shunt capacitor banks and feeder voltage regulators which minimize $I^{2}R$ losses of the distribution system while maintaining all the bus voltages within the limits. The KNN is tested on a distribution system with 30 buses, 5 on-off switchable capacitor banks and a nine tap line voltage regulator.

  • PDF

Modal Analysis and Velocity Control of Bowl Parts Feeder Activated by Piezoactuators (압전작동기로 구동 되는 보울 파트 피더의 모드 해석과 이송 속도 제어)

  • Lee, Dong-Ho;Choe, Seung-Bok;Kim, Jae-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.839-847
    • /
    • 2000
  • This paper presents modal analysis and mean conveying velocity (M.C.V.) control of bowl parts feeder activated by piezoactuators. Bowl parts feeders are being widely used in many industry fields for automatic assembly line. In general, the electromagnet has been and being used as exciting actuator of these vibratory bowl feeders. However, because of complexity of its mechanism and limited capability of the electromagnet actuator, there exist various impending problems such as severe noise, nonlinear motion of parts, passive characteristics and so forth. As one of solutions for these problems, piezoelectric actuators as new actuating technology have been proposed recently to excite the bowl parts feeder. In this paper, modal analysis of the proposed model has been performed to examine the modal characteristics of the model by using commercial FEM software and modeling with respects to MCV is constructed. Finally, MCV of the parts is to be controlled to track the desired one with PID controller.