• Title/Summary/Keyword: feasibility Test

Search Result 1,654, Processing Time 0.032 seconds

Evaluation of the CO2 Storage Capacity by the Measurement of the scCO2 Displacement Efficiency for the Sandstone and the Conglomerate in Janggi Basin (장기분지 사암과 역암 공극 내 초임계 이산화탄소 대체저장효율 측정에 의한 이산화탄소 저장성능 평가)

  • Kim, Seyoon;Kim, Jungtaek;Lee, Minhee;Wang, Sookyun
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.469-477
    • /
    • 2016
  • To evaluate the $CO_2$ storage capacity for the reservoir rock, the laboratory scale technique to measure the amount of $scCO_2$, replacing pore water of the reservior rock after the $CO_2$ injection was developed in this study. Laboratory experiments were performed to measure the $scCO_2$ displacement efficiency of the conglomerate and the sandstone in Janggi basin, which are classified as available $CO_2$ storage rocks in Korea. The high pressurized stainless steel cell containing two different walls was designed and undisturbed rock cores acquired from the deep drilling site around Janggi basin were used for the experiments. From the lab experiments, the average $scCO_2$ displacement efficiency of the conglomerate and the sandstone in Janggi basin was measured at 31.2% and 14.4%, respectively, which can be used to evaluate the feasibility of the Janggi basin as a $scCO_2$ storage site in Korea. Assuming that the effective radius of the $CO_2$ storage formations is 250 m and the average thickness of the conglomerate and the sandstone formation under 800 m in depth is 50 m each (from data of the drilling profile and the geophysical survey), the $scCO_2$ storage capacity of the reservoir rocks around the probable $scCO_2$ injection site in Janggi basin was calculated at 264,592 metric ton, demonstrating that the conglomerate and the sandstone formations in Janggi basin have a great potential for use as a pilot scale test site for the $CO_2$ storage in Korea.

Analyses of Synchronous Fluorescence Spectra of Dissolved Organic Matter for Tracing Upstream Pollution Sources in Rivers (상류 오염원 추적을 위한 용존 유기물질 Synchronous 형광스펙트럼 분석 연구)

  • Hur, Jin;Kim, Mi-Kyoung;Park, Sung-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.317-324
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter(DOM) have the superior advantages over other analysis tools for applying to water quality management. A preliminary study was conducted to test the feasibility of applying synchronous fluorescence measurements for tracing and monitoring pollution sources in a small stream located in an upstream area of the Sooyoung watershed in Busan. The water quality of the small stream is affected by leachate from sawdust pile and discharge of untreated sewage. The sampling sites included an upstream site, two pipes discharging untreated sewage, leachate from sawdust, and a downstream site. Of the five field samples, the leachate was distinguished from the other samples by a high peak at a lower wavelength range and a blunt peak at 350nm, suggesting that synchronous fluorescence can be used as a discrimination tool for monitoring the pollution. The efficacy of various indices derived from the spectral features to discriminate the pollution source was tested for well-defined mixture of the sawdust leachate and the upstream stream by comparing (1)the difference between measured values and those predicted based on mass balance and the characteristics of the two samples and (2)the linear correlations between index values and mass ratios of the sample mixtures. Of various discrimination indices selected, fluorescence intensities at 276 nm$({\Delta}\lambda=30nm)$and 347 nm$({\Delta}\lambda=60nm)$ were suggested as promising potential discrimination indices for the sawdust pollution source. Despite the limited number of samples and the study area, this study illustrates the evaluation process that should be followed to develop rapid, low-cost discrimination indices to monitor pollution sources based on end member mixing analyses.

Evaluation of an Automated Liquid-Handling System with Fixed Pipetting Tips in Radioimmunoassay (고정용 팁을 사용하는 Automated Liquid-Handling System의 RIA적용의 평가)

  • Shin, Sun-Young;Kim, Hee-Sun;Lee, Hyun-Ju;Jang, Hyun-Young;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.190-196
    • /
    • 2010
  • Purpose: This study was undertaken to investigate the feasibility of using automated liquid-handling systems equipped with reusable fixed tips in Radioimmunoassays and to demonstrate that the use of an automated pipetting instrument can decrease in the typical daily workload. Materials and Methods: The precisions of the automated pipettor and the manual pipettor were determined gravimetrically (n=30). A total of 30 specimens for HBs Ag were repeatedly pipetted (three replicates) with the automated pipettor and then retested. PSA samples were simultaneously pipetted with either the automated pipettor or the manual pipettor and then analyzed (n=40). Sample carryover test assessed for CA19-9, AFP and HCG when the automated pipettor was used. Pipetting speed of the automated pipettor and the manual pipettor were compared by evaluation of each workload. Results: The precisions coefficients of variation (CV) were 2.1% for the automated pipettor and 1.6% for manual pipettor. The mean cpm and CV for each group of replicates were 41,203 cpm and 3.7% for HBs Ag positive specimens, and 99 cpm and 7.9% for HBs Ag negative specimens, respectively. PSA results showed no significant differences between automated pipettor and manual pipettor (p=0.15, r=0.999). Carryover for CA19-9, AFP and HCG analytes was <0.1 ppm or below the assay limit of detection. Pipetting speed was significantly improved by using the automated instrument. Conclusion: There was no evidence that the use of an automated pipettor adversely affected any of the performance characteristics of the assay. Indeed, routine use of the Tecan automated pipettor has resulted in a decrease in the typical daily workload.

  • PDF

Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor (판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발)

  • Kim, Hoe Woong;Kim, Sang Hwal;Han, Jae Won;Joo, Young Sang;Park, Chang Gyu;Kim, Jong Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.48-57
    • /
    • 2015
  • In a sodium-cooled fast reactor, which is a Generation-IV reactor, refueling is conducted by rotating, but not opening, the reactor head to prevent a reaction between the sodium, water and air. Therefore, an inspection technique that checks for the presence of any obstacles between the reactor core and the upper internal structure, which could disturb the rotation of the reactor head, is essential prior to the refueling of a sodium-cooled fast reactor. To this end, an ultrasound-based inspection technique should be employed because the opacity of the sodium prevents conventional optical inspection techniques from being applied to the monitoring of obstacles. In this study, a ranging inspection technique using a plate-type ultrasonic waveguide sensor was developed to monitor the presence of any obstacles between the reactor core and the upper internal structure in the opaque sodium. Because the waveguide sensor installs an ultrasonic transducer in a relatively cold region and transmits the ultrasonic waves into the hot radioactive liquid sodium through a long waveguide, it offers better reliability and is less susceptible to thermal or radiation damage. A 10 m horizontal beam waveguide sensor capable of radiating an ultrasonic wave horizontally was developed, and beam profile measurements and basic experiments were carried out to investigate the characteristics of the developed sensor. The beam width and propagation distance of the ultrasonic wave radiated from the sensor were assessed based on the experimental results. Finally, a feasibility test using cylindrical targets (corresponding to the shape of possible obstacles) was also conducted to evaluate the applicability of the developed ranging inspection technique to actual applications.

The Characteristics of Heavy Metal Distributions in the Tissues of Feral Pigeon (Columba livia) as a Bio-monitoring Indicator (환경오염 지표종인 집비둘기의 생체조직 내 중금속 분포 특성)

  • Lee, Jangho;Lee, Jongchun;Park, Jong-Hyouk;Lee, Eugene;Shim, Kyuyoung;Jang, Heeyeon;Kim, Myungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.6
    • /
    • pp.502-513
    • /
    • 2016
  • In this study, heavy metal distributions in the tissues of feral pigeon (Columba livia) were characterized using samples collected from bio-monitoring sites (Hangang Park and Hampyeong Park) of the NESB (National Environmental Specimen Bank), Korea, in order to evaluate the feasibility of feral pigeons as an indicator for the environmental monitoring. Cadmium (Cd) was analyzed to be accumulated in kidneys at higher concentration than in the other tissues. Such trend can also be found in the reviews on the Cd accumulations of the 34 cases including 17 avian species which showed that 31 cases had the highest Cd concentrations in the kidney among tissues. However, lead (Pb) was found to be richest in the bones in this study. 17 cases out of 30 reviewed cases had the highest Pb concentration in bones, whereas other 10 cases showed the highest concentration in kidneys, and 3 cases in livers. Therefore, kidneys together with bones can be a main target organ to test cadmium exposure to different habitat environments depending on physiological traits of birds. Zinc (Zn) was found to be the highest concentration in the pigeon livers of Hangang Park, but not in the bones. In contrast, the 13 cases of 16 reviewed cases had the highest Zn concentration in bones, and the 3 cases in livers. In addition, the heavy metal distribution patterns in relations to the metal accumulation mechanisms (a competition between Pb and Ca, a function of methallothionein protein, and etc.) were discussed.

Feasibility Test of Biohydrogen Production from Food Waste (음식물쓰레기의 수소발효 타당성 평가)

  • Han, Sun-Kee;Kim, Sang-Hyoun;Shin, Hang-Sik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.3
    • /
    • pp.87-95
    • /
    • 2003
  • Although extensive studies were conduced on hydrogen fermentation of organic wastewaters, little is known about biohydrogen production from organic solid wastes. The leaching-bed reactor treating food waste by heat-shocked anaerobic sludge was, therefore, operated at D of 2.1, 3.6, 4.5 and $5.5d^{-1}$ to find optimal D for hydrogen production. Successful operation of a reactor can be accomplished when it is operated at proper dilution rate (D). Operation at high D leads to the washout of biomass in the reactor while operation at low D leads to product inhibition due to the accumulation of excess VFA. These appear to limit the production of hydrogen to reach a higher level. All the reactors showed that, on day 1-3, hydrogen production was dominant and VFA concentration was higher than ethanol. Butyrate and acetate were major components of VFAs over the whole operation, though lactate was very high on day 1-2. Compared with other D values, D of $4.5d^{-1}$, resulted in higher butyrate/acetae (B/A) ratios during the fermentation. The trend of B/A ratios was similar to the hydrogen production, suggesting that butyrate formation favored hydrogen production. Ethanol increased significantly from day 4 when hydrogen Production stopped. It indicated that heat-shocked sludge was able to induce a metabolic flow from hydrogen-and acid-producing pathway to solvent-producing pathway. Operation at D of $4.5d^{-1}$ led to higher fermentation efficiency (58%) than those (51.5, 55.3 and 53.7%) at 2.1, 3.6 and $5.5d^{-1}$. The COD removed was convened to hydrogen (10.1%), VFA (30.9%), and ethanol (17.0%).

  • PDF

Evaluation of Solidified Fuel Value of Dairy Cattle Manure Digested by Semi-Dry Anaerobic Digestion Method (젖소분뇨 반 건식 혐기소화 잔재물의 고체연료화 가능성 평가)

  • Jeong, Kwang-Hwa;Kim, Jung Kon;Lee, Dong-jun;Cho, Won-Mo;Ravindran, B.;Kwag, Jung-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.4
    • /
    • pp.95-103
    • /
    • 2016
  • The objective of this study was to investigate feasibility of semi-dry anaerobic digestion using dairy cattle manure and to evaluate solidified fuel value of semi-dry anaerobic digestate. To evaluate semi-dry anaerobic digestion using dairy cattle manure, 950 mL bottle type anaerobic reactor was set in the constant temperature room maintained at $35^{\circ}C$. To produce anaerobic digestate for making solidified fuel, acrylic cylindrical anaerobic digester(1,000 mm width ${\times}$ 450 mm height) was set in the constant room temperature to carry out batch test of semi-dry anaerobic digestion using same dairy cattle manure. Moisture content of dairy cattle manure and inoculum solution for anaerobic digestion were 80.64% and 96.83%, respectively. The dairy cattle manure and the inoculum solution was mixed by 1:1 ratio(v/v) for anaerobic digestion. Water content and VS/TS(Volatile Solids/Total Solids) of mixture of substrate and inoculum were 89.74% and 83.35%, respectively. In case of non-inoculated anaerobic digester, the biogas was not produced. By the semi-dry anaerobic digestion, the calorific value of the digestate was reduced by 20% compare to fresh dairy cattle manure. In other hand, ash content increased from 15% to 18.4%. The contents of Cr, Pb, Cd and S of pellet produced from anaerobically digested dairy cattle manure were not against the standard regulation for livestock manure solidified fuel. Therefore, it can be used as fuel that anaerobic digestate produced after semi-dry anaerobic digestion using dairy cattle manure.

Lead Level in Hair of Elementary School Children in Urban and Rural Areas (국민학교 저학년 학생들의 두발중 연농도와 관련요인)

  • Byun, Yung-Woo;SaKong, Jun;Kim, Chang-Yoon;Chung, Jong-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.103-113
    • /
    • 1993
  • This study was conducted to explore the feasibility of using the lead level in the hair of children as a screening test for lead intoxication of children and as an indicator for environmental pollution. Lead concentration of hair was measured for 268 seven to nine-year-old elementary school children in Taegu city (147 children) and Gampo town(121 children). The lead level in hair was measured by atomic absorption spectrophotometer equipped with a graphite furnace atomizer. The following information was obtained for all children: sex, age, father's occupation and smoking habits, kinds of hair cleaner, fingernail biting habits, and status of the child's hands and clothing. The mean lead level in hair was $8.7{\pm}2.9{\mu}g/g$ in the urban area and $7.7{\pm}2.2{\mu}g/g$ in the rural area. There were significant differences between two groups(p<0.01). The difference of lead levels in hair measured by cleanliness of the child's hands(clean: $7.4{\pm}2.7{\mu}g/g$, dirty: $8.2{\pm}2.6{\mu}g/g$) and child's clothing(clean: $8.0{\pm}2.5{\mu}g/g$, dirty: $9.3{\pm}2.6{\mu}g/g$) were statistically significant, but other factors were not significant. In multiple regression analysis, difference of residency and age were significant variables for lead level in the hair of children. These findings suggest that measurement of lead level in the hair is a useful method for the screening of the lead intoxication of children and monitoring environmental conditions.

  • PDF

Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems (생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구)

  • 김윤기;고재균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

Fundamental Study on Recycling as Construction Material of Dredged Harbor Soil Mixed with Clay and Glass Frit (점토와 유리프리트를 혼합한 항만준설토의 건축자재 재활용에 관한 기초연구)

  • Im, Dong-Su;Kim, Kyung-Nam;Cho, Yeon-Bae;Park, Joon-Seok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.575-585
    • /
    • 2013
  • This research was performed to evaluate the recycling feasibility as a construction material of dredged harbor soil mixed with clay and glass frit. Concentration of heavy metals of the dredged soil from D harbor was severly high, showing Zn of 526.0~13,150.1 mg/kg. The dredged soil was maily composed of 48.30 wt% $SiO_2$, 16.60 wt% $Al_2O_3$, 10.10 wt% CaO, 7.75 wt% $Fe_2O_3$. The clay and the glass frit contained 70.82 wt% $SiO_2$ and $Al_2O_3$ 18.78 wt%, and 71.75 wt% $SiO_2$, 13.99 wt% CaO, 8.51 wt% $Na_2O$, respectively. After adding 10~40 wt% to the clay and sintering them at $1,000^{\circ}C$ or $1,100^{\circ}C$, the compressive strength of the sintered specimens showed $132.6{\sim}178.5kgf/cm^2$ or $581.2{\sim}793.7kgf/cm^2$, respectively. In case of SC46 with the addition 40 wt% of the dredged soil to the clay, the compressive strength ($793.7kgf/cm^2$) of specimen sintered at $1,100^{\circ}C$ was over 5 times higher than that at $1,000^{\circ}C$. The specimen mixed with 40 wt% of dredged soil, 60 wt% of clay and 1 wt% of glass frit satisfied the 1st grade standard for clay brick by KS L 4201. The results of all specimens by Korean Standard Leaching Test also satisfied the standard criteria.