• 제목/요약/키워드: fault current condition

검색결과 249건 처리시간 0.035초

2세대 도체 344B를 사용한 초전도 모델 케이블에서의 과전류 특성분석 (Over current characteristic analysis of superconducting model cable using 2G wire 344B)

  • 김대원;김아롱;김진근;박민원;유인근;조전욱;심기덕;김석호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.603_604
    • /
    • 2009
  • HTS tape is developed for the purpose of being applied to the power cable, motor and generator, etc. The resistance of conventional power cables is not changed a lot by over current condition. But HTS(High temperature superconductor)power cable has some different properties. The impedance of superconductor is changed due to the magnitude of current, temperature, and magnetic field. And the characteristics analysis of HTS power cable under many kind of fault conditions are important to apply real system. In addition the magnitude of over current is 10 times larger than rated current. In this paper, the characteristics of HTS power cable are analyzed when over current flows. Model cable used 2G wires was made and experimented. The results will be helpful to manufacture real HTS power cable.

  • PDF

고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성 (Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.

철도차량 검수 시험설비에 관한 기술개발 연구 (The research of the Technology Development of the Test Equipment of the Rolling Stocks)

  • 송문석;김문기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.97-102
    • /
    • 2005
  • As the railroad-base is an important factor to maintenance the rolling stocks, it is essential to improve the current problems of the environment pollution, nose, vibration, welfare, work condition and to applicate the performance betterment cases to the new base construction and pre-base maintenance. When the new base construction and pre-base maintenance is proceeded, it is necessary to construct the optimized system which includes the user's opinions enough to prevent the waste of the budget ,in that some part of the budget is spent to improve convenience, work condition, and the fault of base system after the construction. Therefore, this research intends to present the problem of the pre-constructed facilities, the testing operators' opinions, the analysis and the investigation of facilities' improvement, thorough the indication of provisions and the analysis of the result of the survey of testing operators.

  • PDF

Design of the Ground Resistance Measuring System to the Earth-Noise

  • Jung Min-Jae;Joo Hyung-Jun;Lee Ki-Hong;Oh Sung-Up;Jung Jae-Ki;Seong Se-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.566-570
    • /
    • 2001
  • Generally, grounding systems are responsible for the safe operation of a power system. Their performance guarantees equipment protection and personnel safety under condition of the limited ground potential rise and touch voltages as well as step voltages under ground fault conditions. Therefore, it is necessary to measure the ground resistance frequently for checking the performance of grounding system, In this paper the ground resistance measuring system using digital signal processor and high-performance L-C resonant band pass filter is presented. The signal current magnitude for measuring ground resistance in this system is $10^{-1}[A]\;to\;5\times10^{-2}[A]$ and the current frequency is 30[Hz].

  • PDF

봉상접지극의 과도임피던스 특성 (Transient Impedance Characteristics of Grounding Rods)

  • 김일권;김점식;송재용;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.568-572
    • /
    • 2000
  • This paper describes the experimental results of a transient impedance characteristics of grounding rods to a square pulse and standard lightning impulse current. The test were performed on single grounding rod($\phi$ 10mm, 1m) and triple-grounding rods( $\phi$ 10mm, 1m) of equilateral triangles with 5m spacing. For measurements of transient impedance, a pulse generator which can produce square wave of 30ns rise time and 20U Pulse duration was designed and fabricated. In the experiment, transient impedance of the grounding systems have been investigated from the recorded potential and current waveforms. The results showed that the value of the transient impedance is quite higher than the stationary resistance, and provide useful information for the value of a grounding system considered transient characteristics under a high frequency condition such as lightning stokes and ground-fault.

  • PDF

Presentation of a Fault Detecting Method for Power Transmission Line using M-sequence

  • Nishiyama, E.;Kuwanmi, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.86.2-86
    • /
    • 2001
  • The method of pinpointing the place of the abnormalities of a power transmission system analyzes the voltage and the current information from the both ends of a power [1-2]. Now, there are only current and a voltage measuring instrument every about 20km, and the present condition is specifying the breaking down point by viewing of a worker in it. In this research, a power line circuit is assumed to be a line type system, and M-sequence is impressed to the end, it receives at other ends, the crosscorrelation function of input and output is taken, an impulse response is calculated, and the method in comparison with the time of normal is proposed. By this technique ...

  • PDF

전동기 전류분석을 통한 회전자회로 고장진단에 관한연구 (A study on the diagnosis of rater faults through the current analysis)

  • 이영수;;이간운;김현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.801-803
    • /
    • 2003
  • Faults in induction motors can be categorized into mechanical faults and electrical faults, and most mechanical faults result from inferiority or damage of the bearing, while most electrical faults derive from insulation faults of stator windings and rotor bar cracks. When a crack appears on the rotor bar, its efficiency decreases, which increases energy consumption and temperature, reducing the life span of the motor. This kind of fault can only be sensed by the protection relay after the condition has worsened to a certain degree, bringing massive economic loss. This paper will deal with the diagnosis method of rotor bar faults through the load current analysis method of the motor used during operation.

  • PDF

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

단층 운동시 댐 파괴 거동 해석 (Crack Propagation in Earth Embankment Subjected to Fault Movement)

  • 손익준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1988년도 학술세미나 강연집
    • /
    • pp.3-67
    • /
    • 1988
  • Model studies on the response of homgeneous earth embankment dams subjected to strike-slip fault movement have been penomed via centrifuge and finite element analysis. The centrifuge model tests have shown that crack development in earth embankment experiences two major patters: shear failure deep inside the embankment and tension failure near the surface. The shear rupture zone develops from the base level and propagates upward continuously in the transverse direction but allows no open leakage chnnel. The open tensile cracks develop near the surface of the embankment, but they disappear deep in the embankment. The functional relationship has been developed based on the results of the centrifuge model tests incorporating tile variables of amount of fault movement, embankment geometry, and crack propagation extent in earth des. This set of information can be used as a guide line to evaluate a "transient" safety of the duaged embankment subjected to strike-slip fault movement. The finite element analysis has supplemented the additional expluations on crack development behavior identified from the results of the centrifuge model tests. The bounding surface time-independent plasticity soil model was employed in the numerical analysis. Due to the assumption of continuum in the current version of the 3-D FEM code, the prediction of the soil structure response beyond the failure condition was not quantitatively accurate. However, the fundamental mechanism of crack development was qualitatively evaluated based on the stress analysis for the deformed soil elements of the damaged earth embankment. The tensile failure zone is identified when the minor principal stress of the deformed soil elements less than zero. The shear failure zone is identified when the stress state of the deformed soil elements is at the point where the critical state line intersects the bounding surface.g surface.

  • PDF

Seq2Seq 모델 기반의 로봇팔 고장예지 기술 (Seq2Seq model-based Prognostics and Health Management of Robot Arm)

  • 이영현;김경준;이승익;김동주
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.242-250
    • /
    • 2019
  • 본 논문에서는 인공신경망(Artificial Neural Network) 모델 중, 시계열 데이터의 변환을 위한 모델인 Seq2Seq(Sequence to Sequence) 모델을 이용한 산업용 로봇 고장 예지 기술에 대하여 제안한다. 제안 방법은 고장 예지를 위한 추가적인 센서의 부착 없이 로봇 자체적으로 측정 가능한 관절 별 전류와 각도 값을 데이터로 사용하였고, 측정된 데이터를 모델이 학습할 수 있도록 전처리한 후, Seq2Seq 모델을 통해 전류를 각도로 변환하도록 지도 학습 하였다. 고장 진단을 위한 이상 정도(Abnormal degree)는 예측 각도와 실제 각도 간의 단위시간 동안의 RMSE(Root Mean Squared Error)를 사용하였다. 제안 방법의 성능평가는 로봇의 정상 및 결함 조건을 달리한 상태에서 측정한 테스트 데이터를 이용하여 수행되었고 이상 정도가 임계값 넘어가면 고장으로 분류하게 하여, 실험으로부터 96.67% 고장 진단 정확도를 보였다. 제안 방법은 별도의 추가적인 센서 없이 고장 예지 수행이 가능하다는 장점이 있으며, 로봇에 대한 깊은 전문지식을 요구하지 않으면서 수행할 수 있는 방법으로 높은 진단 성능과 효용성을 실험으로부터 확인하였다.