• Title/Summary/Keyword: fatigue of concrete

Search Result 475, Processing Time 0.038 seconds

Perforated shear connectors

  • Machacek, Josef;Studnicka, Jiri
    • Steel and Composite Structures
    • /
    • v.2 no.1
    • /
    • pp.51-66
    • /
    • 2002
  • Perforated shear connectors currently used in composite steel and concrete structures are described and evaluated. Modifications of the perforated connector suitable for common use injavascript:confirm_mark('abe', '1'); civil and bridge engineering are proposed. The connectors were tested in laboratories of CTU Prague for shear load capacity. Push tests of connectors with 32 mm openings and with 60 mm openings, both in normal and lightweight concrete of different strength characteristics and with different transverse reinforcement, were carried out. The experimental study also dealt with the connector height and parallel arrangement of two connectors and their influence on shear resistance. While extensive tests with static loading were carried out, fatigue tests under repeated loading are still in progress. After statistical evaluation of the experimental results and comparisons with other available data the authors developed reasonable shear resistance formulas for all proposed arrangements.

Improvement in Fatigue Durability of RC Beams Strengthened with Carbon Fiber Sheets (탄소섬유시트로 보강된 RC 보의 피로내구성 향상에 관한 연구)

  • Park, Jeong-Yong;Kim, Seong-Do;Jo, Baik-Soon;Kim, In-Tae;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.205-212
    • /
    • 2006
  • In recent investigations, reinforced concrete beams strengthened with Carbon Fiber Sheets (CFS) subjected to fatigue loading were reported to be failed at the ends of CFS by its debonding. U-shaped CFS were attached to both ends of the CFS when fatigue tests on strengthened beams were conducted to delay and/or prevent fatigue failures of adhesive interface. The experimental parameters of this study were the usage of anchorage at the ends of CFS, the number of CFS layers, and the applied load levels of 60%~90% of the static ultimate load obtained from the static tests. The failure modes and the load cycle-deflection relations were observed and discussed from the experimental results. Those results also showed that the U-shaped anchoring system changes the fatigue failure modes and influences greatly on the fatigue capacity of the strengthened beams.

Structural Response of Reinforced Concrete Beams Strengthened with CERP Rod

  • Moon Do-Young;Sim Jong-Sung;Oh Hong-Seob
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1085-1090
    • /
    • 2005
  • Rod-type fiber reinforced polymer plastics(FRPs) similar to reinforcing steel bars have rarely been considered. In this study, an experiment was performed using beams strengthened with rod-type CFRPs and high-strength mortar overlay. The test results show that the strengthened beams not only had improved endurance limits but also improved load carrying capacities, stiffness values, and cracking loads as compared to a non-strengthened beam. Strengthened beams anchored with bolts throughout their entire span had more efficient structural behaviors, including composite behavior on the interface between the concrete and mortar, and load carrying capacity, than a strengthened beam anchored only on the end block.

Interface monitoring of steel-concrete-steel sandwich structures using piezoelectric transducers

  • Yan, Jiachuan;Zhou, Wensong;Zhang, Xin;Lin, Youzhu
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1132-1141
    • /
    • 2019
  • Steel-concrete-steel (SCS) sandwich structures have important advantages over conventional concrete structures, however, bond-slip between the steel plate and concrete may lead to a loss of composite action, resulting in a reduction of stiffness and fatigue life of SCS sandwich structures. Due to the inaccessibility and invisibility of the interface, the interfacial performance monitoring and debonding detection using traditional measurement methods, such as relative displacement between the steel plate and core concrete, have proved challenging. In this work, two methods using piezoelectric transducers are proposed to detect the bond-slip between steel plate and core concrete during the test of the beam. The first one is acoustic emission (AE) method, which can detect the dynamic process of bond-slip. AE signals can be detected when initial micro cracks form and indicate the damage severity, types and locations. The second is electromechanical impedance (EMI) method, which can be used to evaluate the damage due to bond-slip through comparing with the reference data in static state, even if the bond-slip is invisible and suspends. In this work, the experiment is implemented to demonstrate the bond-slip monitoring using above methods. Experimental results and further analysis show the validity and unique advantage of the proposed methods.

Design of Shear connection in Full-Depth Precast Concrete Deck Bridge (프리캐스트 콘크리트 바닥판 교량의 전단연결부 설계)

  • Chang, Sung Pil;Shim, Chang Su;Kim, Jong Hee;Kim, Young Jin
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.759-767
    • /
    • 1998
  • Full-depth precast concrete deck bridge has shear pockets for shear connectors that give composite action with steel girder. Strength and shear stiffness of shear connection that is needed to design shear connectors in case that shear pockets are filled with nonshrink mortar are investigated. In case that simple span full-depth precast concrete deck bridge is designed by allowable stress design, distribution of shear connector is suggested and details of precast panel that is placed on the support are proposed. Appropriate distribution of shear connectors in strength design and fatigue design is investigated through parameter analyses using partial interaction theory. The effects of nonshrink mortar strength is studied using the results of experiments and analyses and adequate strength is proposed.

  • PDF

Evaluation of Physical and Mechanical Characteristics of Korean Epoxy Asphalt Mixtures (국산 에폭시 아스팔트 혼합물의 물리.역학적 특성 평가)

  • Kim, Byung-Hun;Baek, Jong-Eun;Lee, Hyun-Jong;Park, Hee-Mun
    • International Journal of Highway Engineering
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2012
  • This study evaluated the performance of Korean epoxy asphalt mixtures using several laboratory tests. Four types of epoxy asphalt mixtures were manufactured based on 13mm dense graded asphalt mixtures: three Korean and one Japanese epoxy asphalt mixtures where 20% or 40% of asphalt binder was replaced by epoxy resins. Curing time was determined as 3 and 6 hours for the mixtures containing 40% and 20% of epoxy resins, respectively. From the laboratory tests including wheel tracking, indirect tension fatigue, bending beam, and moisture susceptibility tests, it was concluded that the epoxy asphalt mixtures had superior performance than conventional asphalt mixtures except moisture susceptibility. Also, the performance of the Korean epoxy asphalt mixtures was comparable to the Japanese mixtures. Thermal coefficient, bond strength, and indirect tension tests were conducted to examine the applicability of the Korean epoxy asphalt mixtures to concrete repair. Its adhesion was strong enough to be bonded to surrounding concrete materials and its tensile strength was comparable to the concrete, but thermal expansion coefficient was 5 times greater than the surrounding concrete.

Strengthening Capacity of Bridge Deck Strengthened with Carbon Fiber Rod and Polymer Mortar (고강도 폴리머 모르타르 및 탄소섬유 봉(Rod)으로 보강된 교량 바닥판의 보강성능)

  • Sim Jongsung;Moon Do-Young;Ju Mm-Kwan
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.213-220
    • /
    • 2004
  • This paper deals with an enhanced structural capacity of reinforced concrete bridge deck strengthened with carbon fiber rod (CFR) which is subjected to monotonic and cyclic loads. Strengthening variables considered in this test were evenly and unevenly strengthening type. To evaluate strengthening capacity for these two strengthening types, load-carrying capacity and crack and failure pattern from the failure test were analyzed and fatigue response were examined. According to the test results, all the strengthened specimens showed punching shear failure as a result of premature failure of bonding interface between mortar and concrete. In the case of strengthening capacity, it was observed that the strengthened specimens was more effective in strength, stiffness and fatigue endurance limit than the unstrengthened specimen. In addition, the unevenly strengthening method (CR-UE) was more effective than the evenly strengthening method (CR-E).

A Study on the Service Load State Behavior of Reinforced Concrete Plate Member

  • Bhang, Jee-Hwan;Kang, Won-Ho
    • KCI Concrete Journal
    • /
    • v.12 no.2
    • /
    • pp.55-72
    • /
    • 2000
  • This paper proposes a mechanical model to describe the load-deformation responses of the reinforced concrete plate members under service load state. An Analytical method is introduced on the basis of the rotating crack model which considers equilibrium, compatibility conditions, load-strain relationship of cracked member, and constitutive law for materials. The tension stiffening effect in reinforced concrete structures is taken into account by the average tensile stress-strain relationship from the load-strain relationship for the cracked member and the constitutive law for material. The strain compatibility is used to find out the crack direction because the crack direction is an unknown variable in the equilibrium and compatibility conditions. The proposed theory is verified by the numerous experimental data such as the crack direction, moment-steel strain relationship, moment-crack width relationship. The present paper can provide some basis for the provision of the definition of serviceability for plate structures of which reinforcements are deviated from the principal stresses, because the present code defines the serviceability by the deflection, crack control, vibration and fatigue basically for the skeletal members. The proposed theory is applicable to predict the service load state behavior of a variety of reinforced concrete plate structures such as skew slab bridges, the deck of skew girder bridges.

  • PDF

Minimum cost design of overhead crane beam with box section strengthened by CFRP laminates

  • Kovacs, Gyorgy;Farkas, Jozsef
    • Structural Engineering and Mechanics
    • /
    • v.61 no.4
    • /
    • pp.475-481
    • /
    • 2017
  • An overhead travelling crane structure of two doubly symmetric welded box beams is designed for minimum cost. The rails are placed over the inner webs of box beams. The following design constraints are considered: local buckling of web and flange plates, fatigue of the butt K weld under rail and fatigue of fillet welds joining the transverse diaphragms to the box beams, fatigue of CFRP (carbon fibre reinforced plastic) laminate, deflection constraint. For the formulation of constraints the relatively new standard for cranes EN 13001-3-1 (2010) is used. To fulfill the deflection constraint CFRP strengthening should be used. The application of CFRP materials in strengthening of steel and concrete structures are widely used in civil engineering applications due to their unique advantages. In our study, we wanted to show how the mechanical properties of traditional materials can be improved by the application of composite materials and how advanced materials and new production technologies can be applied. In the optimization the following cost parts are considered: material, assembly and welding of the steel structure, material and fabrication cost of CFRP strengthening. The optimization is performed by systematic search using a MathCAD program.